• Title/Summary/Keyword: 두께 변형률 분포

Search Result 57, Processing Time 0.021 seconds

Investigation of Strain Behaviour around the Tip of Model Pile - Comparison between Laboratory Model Test and Numerical Analysis - (모형말뚝 선단부 주변의 변형률 거동 분석 - 실내모형실험과 수치해석 비교 -)

  • Lee, Yong Joo;Lee, Jung-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.159-167
    • /
    • 2012
  • In this study, laboratory model pile-load test and finite element analysis were carried out to compare and analyze the strain behaviour around the model pile tip. In order to simulate the pile load, both the LCM(load control method)and DCM(displacement control method) were introduced to determine which one is appropriate for the FE simulation. In contrast to the previous simulation method, two interface elements around the model pile were used to consider the slip effect in the finite element analysis and its results were compared to the model test. Through this study it was found that the degree of non-associated flow was a dominant factor in terms of numerical solution convergence. In addition, an improved FE mesh was required to obtain the symmetric distribution of the maximum shear strain contour.

Stiffness Reduction Effect of Vertically Divided Reinforced Concrete Shear Walls Under Cyclic Loading (반복하중을 받는 수직분할된 철근콘크리트 전단벽의 강성저감효과)

  • Hwangbo, Dong-Sun;Son, Dong-Hee;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.103-110
    • /
    • 2022
  • The purpose of this study is to experimentally evaluate the stiffness and strength reduction according to the reinforcing bar details of the vertically divided reinforced concrete shear walls. To confirm the effect of reducing strength and stiffness according to vertical division, four real-scale specimens were fabricated and repeated lateral loading tests were performed. As a result of the experiment, it was confirmed that the strength and stiffness were decreased according to the vertical division. In particular, as the stiffness reduction rate is greater than the strength reduction rate, it is expected that safety against extreme strength can be secured when the load is redistributed according to vertical division. As a result of checking the crack pattern, a diagonal crack occurred in the wall subjected to compression control among the divided walls. It was confirmed that two neutral axes occurred after division, and the reversed strain distribution appeared in the upper part, showing the double curvature pattern. In future studies, it is necessary to evaluate the stiffness reduction rate considering the effective height of the wall, to evaluate additional variables such as wall aspect ratio, and to conduct analytical studies on various walls using finite element analysis.

Effect of Strength Parameter a in the Generalized Hoek-Brown Failure Criterion and the Reinforcement Thickness on the Elasto-plastic Behavior of Circular Tunnel (일반화된 Hoek-Brown 파괴조건식의 강도정수 a와 터널 보강깊이가 원형터널의 탄소성 거동에 미치는 영향)

  • Lee, Youn-Kyou;Park, Kyung-Soon
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.20-28
    • /
    • 2008
  • In the design stage of a tunnel, the wall convergence is commonly estimated through an elasto-plastic analysis of the tunnel, which has been a topic drawing many researcher's attention so far. Despite its importance, however, the elasto-plastic behavior of a circular tunnel excavated in a generalized Hoek-Brown rockmass is still poorly understood. In this study, a simple munerical method based on Lee & Pietruszczak (2008) for the elasto-plastic analysis of a circular tunnel surrounded by reinforced annulus is proposed. It is assumed that the tunnel is excavated in a strain-softening rockmass obeying the generalized Hoek-Brown failure condition. The commercial code FLAC is used for the verification of the proposed method. The influence of the Hoek-Brown strength parameter a and the thickness of the reinforcement annulus on the elasto-plastic behavior around the tunnel was discussed by conducting some example analyses. The results show that the influence of these two parameters on the distribution of stresses and displacements is substantial.

Nonlinear Numerical Analysis for Shear Dominant RC Columns Subjected to Lateral Force (전단거동이 우세한 기둥의 비선형 해석에 관한 연구)

  • Kim Ick-Hyun;Sun Chang-Ho;Lee Jong-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.467-476
    • /
    • 2004
  • Because of crack control by steel bars after cracking the material models for reinforced concrete(RC) differ from those for plain concrete(PL). The nonlinear behavior of columns subjected to lateral load was simulated with reasonable accuracy in 3D analysis by applying distinct material models for RC and PL zone subdivided properly on the section. The shear strain is confirmed to develope unstably with ununiform distribution in out-of-plane direction. And this tendency becomes stronger as the thickness of column member increases in out-of-plane direction. If this ununiformity in strain distribution is not taken into consideration the capacity and the deformability of columns in shear dominant failure are overestimated excessively in two dimensional analysis. By introducing equivalent softening model a behavior of columns can be predicted too in two dimensional analysis.

Dynamic Behavior of Decomposed Granite Soils (화강풍화토의 동적 거동)

  • 이종규
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.175-183
    • /
    • 1999
  • Recently, problems related to vibrations of decomposed granite soils have acquired increasing attention in Korea because those soils cover approximately one third of the country. Both resonant column and cyclic triaxial test were performed to investigate deformation characteristics of unsaturated and cement-mixed decomposed granite soils in Suwon region. The important soil parameters in this respect are the shear moduli, dynamic moduli of elasticity and damping ratios. The dynamic parameters are influenced by variables such as strain amplitude, ratio of loading cycles, and degree of saturations, etc. Test results and data have shown that the optimum degree of saturation to the maximum shear modulus due to a capillary menisci effect was about 17~18 % at low strain amplitude and 10~15 % at intermediate strain amplitude. This paper suggests the range of threshold strain and mean shear modulus of decomposed granite soils in Suwon region. It also proposed the empirical relationship between the dynamic parameters for cement-mixed and non-mixed decomposed granite soils.

  • PDF

Dynamic Properties and Settlement Characteristics of Korea Weathered Granite Soils (화강풍화토의 동적 물성치와 침하특성에 대한 연구)

  • Park, Jong-Gwan;Kim, Yeong-Uk;Lee, In-Mo
    • Geotechnical Engineering
    • /
    • v.9 no.2
    • /
    • pp.5-14
    • /
    • 1993
  • Weathered granite soil is the most representative as a surface soil in Korea. In this paper, the dynamic properties and settlement characteristics of Korea granite soil are studied through the dynamic triaxial compression tests. The dynamic characteristics are very important on the analysis of the foundations under dynamic loading such as machine vibration and earthquake. Soil samples having different grain sixtes were prepared at the relative densities between 80oA and 90oA and tested to measure shear moduli and damping ratios at each level of shear strain. The measured shear moduli of weathered granite soils showed large variations according to the grain sizes, confining pressures, relative densities and shear strains. Sandy weathered granite had a little larger dynamic properties than the average values of the sand studied by Seed and Idriss. Pot the well compacted granite soils, little residual settlements occured due to dynamic loading.

  • PDF

Undamped Forced Vibration Response of Curved Composite Panels using Enhanced Assumed Strain Finite Element-Direct Integration Method (추가변형률 유한요소-직접적분법을 이용한 복합적층 곡선패널의 비감쇠 강제진동응답)

  • Park, Won-Tae;Chun, Kyoung-Sik;Son, Byung-Jik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.247-258
    • /
    • 2004
  • The composite shell element is developed for the solution of undamped forced vibration problem of composite curved panels. The finite element used in the current study is an 4-node enhanced assumed shell element with six degrees of freedom per node. The composite shell element is free of both shear and membrane locking phenomenon by using the enhanced assumed strain(EAS) method. A modification to the first-order shear deformation shell theory is proposed, which results in parabolic thorough-thickness distribution of the transverse shear strains and stresses. It eliminates the need for shear correction factors in the first order theory. Newmark's direct integration technique is used for carrying out the integration of the equation motion, to obtain the repones history. Parametric studies of curved composite panels are carried out for forced vibration analysis by geometrical shapes and by laminated composite; such as fiber orientation, stacking sequence.

Analysis of Calcite Twins as Indicators of Paleostress History (고응력의 지시자로서 방해석 쌍정 분석연구)

  • Park, Young-Seog;Jang, Bo-An;Kim, Cheong-Bin;Kang, Seong-Seung
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.461-471
    • /
    • 2007
  • A temperature of deformation and the state and direction of paleostress at that time when twins in calcite grains had been produced were observed, using analysis of calcite twins as indicators of paleostress history. The study was performed with the target of carbonate rocks distributed randomly small size in the southern area of south Korea. Considering the appearance of twins (thin or thick straight twins with one or two twin sets), average twin strain (1.235-7.453%), thickness ($0.77-1.94{\mu}m$) and intensity (25.26-41.99 twins/mm) from the results of calculated calcite twins, it is estimated that calcite twins were produced under temperatures lower than approximately $150-200^{\circ}C$. In the magnitudes and directions of principal strains, the maximum shortening strain axis ($e_3\leftrightarrow{\sigma}_1$) is approximately N-S direction in the GS-1 area in the southern Gyeongsang Basin as well as in the BS-1 area in the southern Yongnam Massif, whereas E-W direction in the NR-1 area in the southwestern Ogcheon Fold Belt. In case of the maximum extension strain axis ($e_1\leftrightarrow{\sigma}_3$), it is oriented in NW-SE and NE-SW directions in the GS-1 and BS-1 area, respectively, and in N-S direction in the NR-1 area. That is, it is suggested that the paleostress which produced the calcite twins may be applied at least more than two times in the study area.

Static Experiment of Reinforced Concrete Frame Retrofitted with Steel Damper System (강재댐퍼시스템으로 내진보강된 철근콘크리트 골조의 정적가력실험)

  • Baek, Eun Rim;Lee, Sang Ho;Oh, Sang Hoon;Kim, Jae Bong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.90-90
    • /
    • 2011
  • 최근 전 세계적으로 지진의 발생 빈도가 증가하며 그 규모도 점차 커지는 경향을 보이고 있다. 대형지진의 발생 시 저층 구조물의 붕괴로 인한 인명 및 사회, 경제적 피해가 두드러짐에 따라 기존 저층 구조물의 내진보강기법에 관한 연구가 활발히 진행 중인 추세이다. 우리나라의 경우 강도증가형 내진보강공법이 주를 이루고 있어 다양한 내진보강기법의 개발 및 적용이 필요한 실정이다. 따라서 본 연구에서는 지진입력하중 저감형 내진보강기법으로서 강재댐퍼시스템을 제안하여 구조적 성능을 파악하고, 이를 적용한 보강 실험체와 비보강 실험체를 제작하여 정적가력실험을 통하여 그 성능을 비교하였다. 제안된 강재댐퍼시스템은 입력에너지를 소산시키는 내부의 슬릿형 댐퍼와 이를 지지하는 기둥 및 외부 프레임으로 구성되며, 내부 댐퍼는 먼저 항복하여 에너지를 소산시키기 위하여 지지기둥 및 프레임에 사용된 강재보다 강성 및 강도가 적게 계획되었다. 강재댐퍼의 성능실험 결과, 비교적 안정적 거동을 하며, 강성과 강도 및 에너지 흡수능력이 우수하게 나타났다. 보강 및 비보강 실험체의 골조는 기존 학교 건축물의 표준도면을 기준으로 하여 골조의 일부를 대상으로 60% 축소율을 적용하여 계획하였으며, 보강 실험체는 미리 제작된 강재댐퍼시스템을 골조 내에 설치하여 에폭시 주입법으로 부착시공 하였다. 보강 및 비보강 골조 실험체의 정적가력 실험결과 비보강 실험체는 기둥의 휨 항복 후 변형의 증가에 따라 휨 및 전단 균열이 증가하면서 최종적으로 기둥이 전단파괴 되었으며, 보강 실험체는 비보강 실험체에 비하여 기둥 및 보의 균열이 적고, 골조에 골고루 분포되어 파괴 규모가 감소하였다. 최대 강도면에서 보강 실험체는 비보강 실험체에 비하여 약 3.4배 우수하였으며, 초기강성은 약 7배 가량 유리한 것으로 평가되어 제안된 강재댐퍼시스템이 강도면에서 우수한 성능을 나타냄을 알 수 있었다. 또한 두 실험체의 기둥 주근 및 띠철근의 변형률을 비교한 결과, 비보강 실험체는 대부분의 철근이 항복하여 큰 변형을 일으킨 반면, 보강실험체에서는 철근의 항복현상이 나타나지 않았고 댐퍼가 항복을 하면서 큰 변형을 일으켰다. 이를 통해 지진하중 입력 시 댐퍼에서 입력 에너지를 흡수하여 큰 하중을 부담하며, 기존의 구조부재에는 입력 에너지가 낮아 손상이 보다 적게 발생함을 확인하였다.

  • PDF

Finite Element Analysis for the Forging Process Design of a Blind Rivet (블라인드 리벳의 단조공정설계를 위한 유한요소해석)

  • Byun, Hong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2577-2582
    • /
    • 2009
  • A rivet which can fasten two parts is one of an important mechanical elements. In this study, the process design of a blind revet is implemented using finite element method in order to manufacture it which can resist high vibration and has strong coherence between two parts. Considering plastic flow, ease of manufacture, high strength, material loss, and so forth, an optimal four-stage process is proposed by finite element analysis and process design rules. In addition, the finite element simulation results such as shape of the forged rivet, strain distribution and forging load are investigated for the usefulness of the forging process of the blind rivet. These results will be contributed to the forging process design and the die design of the blind rivet.