• Title/Summary/Keyword: 동종 경골건

Search Result 21, Processing Time 0.022 seconds

Comparison of ACL Reconstructions using Quadrupled Hamstring tendon Autograft and Tibialis tendon Allograft (자가 슬괵건과 동종 경골건을 이용한 전방십자인대 재건술의 비교)

  • Lee, Kwang-Won;Lee, Seung-Hun;Yang, Dong-Hyun;Kang, Sung-Il;Choy, Won-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • Purpose: The purpose of this study was to compare the clinical outcomes of ACL reconstruction using autogenous hamstring tendon and allo-tibialis tendon. Materials and Methods: Between March 2002 and March 2005, We performed 30 ACL reconstuructions using hamstring autograft and 20 ACL reconstuructions using tibialis tendon allograft. The average follow up period was 22 months in auto-hamstring tendon and 18 months in allo-tibialis tendon. For the clinical evaluation, we measured the Lysholm score, International Knee Documentation Committee(IKDC) score and anterior laxity by KT-2000 arthrometer at final follow up and compare the results between two groups. Results: The Lysholm score improved from 69.5 preoperatively, to 95.3 at final follow-up in the hamstring autograft groups and from 69.0 to 90.4 in the tibialis allograft groups. According to the IKDC evaluation form, 80% of autogenous hamstring tendon group and 73% of allograft group were good results, higher than B(almost normal)(p>0.05). The average KT-2000 arthrometer side-to-side difference, decreased from 7.1mm preoperatively, to 1.8mm at final follow-up in the hamstring autograft groups and from 7.4 mm to 2.4mm in the tibialis allograft groups. Conclusion: The clinical results of ACL reconstruction using auto-hamstring tendon and allo-tibialis tendon showed no significant differences. The allo-tibialis tendon is an acceptable substitute for auto-hamstring tendon in ACL reconstruction.

  • PDF

Comparison of Clinical Results and Second-Look Arthroscopy after Anterior Cruciate Ligament Reconstruction using Hamstring Tendon Autograft, Mixed graft and Tibialis Tendon Allograft (자가슬괵건, 혼합건 및 동종 경골건을 이용하여 실시한 전방십자인대 재건술후 임상결과 및 이차관절경 검사 비교)

  • Cho, Jin-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.18-26
    • /
    • 2011
  • Purpose: This study is to compare the clinical results of ACL reconstruction between three groups using hamstring tendon autograft, mixed and tibialis tendon allograft. Materials and Methods: Between August 2003 and August 2008, we analyzed 169 cases of ACL reconstruction, 66 cases used hamstring tendon autograft, 42 cases used mixed graft and 61 cases used tibialis tendon allograft, with a minimum follow-up of 12 months. For the clinical evaluation, we evaluated the Lysholm score, Telos stress test device and IKDC score. Results: The average side to side difference in Telos stress test decreased from $7.5{\pm}1.0$ mm to $1.6{\pm}1.0$ mm in autograft group, from $7.6{\pm}1.1$ mm to $1.4{\pm}1.1$ mm in mixed graft group and from $7.4{\pm}1.3$ mm to $2.5{\pm}1.3$ mm in allograft group. The average Lysholm knee score improved from 58.6 to 92.3 in autograft group, from 60.6 to 92.6 in mixed graft group and from 55.3 to 91.5 in allograft group. There was no significant difference between three groups in clinical results. At second look arthroscopy, tension of ligament and synovial coverage were good result in autograft and mixed graft than allograft group. Conclusion: All hamstring tendon autograft, mixed graft and tibialis tendon allograft groups showed satisfactory clinical results, with no significant difference in outcomes between the groups. Both hamstring tendon autograft and mixed graft showed good synovial coverage in second look arthroscopy. So mixed graft will be considered as good alternative in case of shorter or thin harvested hamstring tendon.

  • PDF

Comparison of Anterior Cruciate Ligament Reconstructions Using Hamstring Tendon Autograft and Tibialis Tendon Allograft (자가 슬괵건 및 동종 경골건을 이용한 전방 십자 인대 재건술의 결과 비교)

  • Song, Eun-Kyoo;Seon, Jong-Keun;Bae, Bong-Hyun;Park, Sang-Jin;Kim, Jong-Seon;Lee, Dam-Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • Purpose: To compare the clinical and radiological results of anterior cruciate ligament(ACL) reconstruction using hamstring autograft and tibialis tendon allograft. Materials and Methods: Twenty four ACL reconstructions using hamstring autograft and 30 using tibialis anterior tendon altograft were followed up at least 1 year. We performed femoral tunnel fixation with Ligament Anchor(LA) screw and tibial tunnel fixation with biodegradable interference screw. Evaluations included Lysholm knee(LK) score, Tegner activity scale, Lachman test, Pivot-Shift test, Quardriceps atrophy, incision site numbness, anterior knee pain and instrumented anterior laxity with $Telos^{(R)}$ device. Results: Preoperativ mean LK score was $60.3(18{\sim}82)$ in autograft group and 61.2(25-80) in allograft group. Mean LK score improved to $91.6(68{\sim}100)\;and\;92.6(77{\sim}100)$ respectively. Activity level, using Tegner activity scale, slightly decreased compared with that of Preinjury state in both groups. Lachman test, pivot-shift test, Quadriceps atrophy, anterior knee pain, incision site numbness, and anterior drawer test using $Telos^{(R)}$ device showed no significant difference between two groups (p>0.05). Conclusion: In performing the ACL reconstruction, there was no statistically significant difference between hamstring autograft group and tibilis anterior allograft group in clinical or in radiological results.

  • PDF

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF

The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$ (Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과)

  • Kim, Doo-Sub;Rah, Jung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • Purpose: We used tibialis allograft for the reconstruction of ACL and used Hybrid femoral fixation utilizing $Endobutton^{(R)}$ and $Rigidfix^{(R)}$ for femoral fixation, and used $Retroscrew^{(R)}$ and additional fixation for tibial fixation to evaluate the clinical results. Materials and Methods: The ACL reconstruction were performed from February 2004 to February 2007 utilizing Hybrid femoral fixation and $Retroscrew^{(R)}$ and 32 patients, 32 cases which were available for year-long observation (12 to 25 months). The clinical results (Lysholm knee score, IKDC grade) and the radiologic results(bone tunnel expansion, Telos anterior displacement test) were evaluated. Results: The Lysholm knee score was improved from the average of $67.9{\pm}5.4$ points (range: 51~77) before operation and to $94.1{\pm}6.8$ points (range: 68~98) at the last follow up (p<0.05). 22 cases (69%) were evaluated normal (A), 9 cases (28%) were evaluated nearly normal (B) and only 1 case (3%) was evaluated not normal (C) at IKDC final evaluation and no case was evaluated abnormal. From $Telos^{(R)}$ stress x-ray evaluation, difference from the opposite knee was improved average 13.2 mm{\pm}5.8 (range: 6~21 mm) to average $3.4\;mm{\pm}2.8$ (range: 0~11 mm) after operation (p<0.05). The femoral and tibial tunnel were widened by 18.7% and 9.6% in the AP view and 12.4% and 8.5% in the lateral view, respectively (p<0.05). However, any statistic significance was not observed between bone tunnel expansion and knee joint functions (p>0.05). Conclusion: An ACL reconstruction with tibialis allograft using Hybrid femoral fixation and $Retroscrew^{(R)}$ enabled anatomical fixation of the graft tendon with satisfactory clinical results.

  • PDF

Reconstruction of Anterior Cruciate Ligament with Fresh-frozen Achilles Allograft (신선 동결 동종 아킬레스건을 이용한 전방 십자인대 재건술)

  • Choi, Nam-Yong;Han, Suk-Ku;Nah, Ki-Ho;Seo, Sang-ll;Lee, Do-Sung;Song, Hyun-Seok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2004
  • Purpose: We analyzed the clinical results of ACL(anterior cruciate ligament) reconstruction of chronic anterior cruciate ligament injuries with a fresh frozen Achilles allograft, retrospectively. Methods: Thirty-eight patients(average age 32.4 years) who had an chronic injury of ACL reconstructed with an Achilles allograft between January 1999 and February 2001 were included. The mean follow-up was 19.2(12-36) months. The clinical evaluation was done by range of motion, Lachman and pivot-shift test, KT-1000 arthrometer, Lysholm knee score, and the modified Feagin score. Results: All patients recovered full range of motion of affected knees. With use of Lachman and pivot-shift test data, thirty seven(97.4%) were functional. When comparing KT-1000, we found mean maximum side-to-side differences less than 2.1 mm. According to Lysholm knee score, mean postoperative score was 90.4. Thirty four(89.5%) had good to excellent results in modified Feagin score. Conclusion: Results of ACL reconstruction using fresh frozen Achilles allografts were comparable to autografts. ACL reconstruction with Achilles allograft could be a reasonable altemative to autografts.

  • PDF

Pretibial Cyst After Arthroscopic Revisional Anterior Cruiate Ligament Reconstruction - A Case Report - (전방 십자 인대 재재건술 후 발생한 전경골 낭종 - 증례 보고 -)

  • Kim, Ha-Kyung;Yoon, Jung-Ro;Kim, Taik-Sun;Yeo, Eui-Dong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.225-228
    • /
    • 2008
  • Pretibial cyst formation is a rare occurrence after anterior cruciate ligament (ACL) reconstruction. We report this complication after ACL revision surgery using tibialis anterior allograft. This complication seems to be the consequence of a direct communication between the joint and the cyst through the tibial tunnel. In the present study, the authors report that there is a pretibial cyst formation after a revisional ACL reconstruction.

  • PDF

PCL Reconstruction using Arthroscopic Posterior Transseptal technique (관절경하 후격막 통과 도달법을 이용한 후방 십자 인대의 재건술)

  • Kim, Jin-Goo;Kang, Yeong-Hun;Kang, Kyoung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.111-116
    • /
    • 2000
  • Purpose : We reviewed the results of arthroscopic posterior cruciate ligament reconstruction using Achilles tendon allograft, and the efficacy of the surgical technique using gradual tibial tunneling and posterior transseptal technique. Materials and Methods : From september 1997 to September 1999, 8 patients with complete PCL injury were treated by arthroscopic PCL reconstruction using Achilles tendon allograft. Mean follow-up period was 21.7 months. Mean preoperative posterior laxity was 14mm. The clinical outcome was assessed by Telos stress test, Lysholm knee score and IKDC score. Result : There was no complication such as infection and neurovascular injury. Posterior translation using Telos device was less than 5mm in 6 cases$(75\%)$, and between 6 to 10mm in 2 cases$(25\%)$. The mean Lysholm knee score was 45 preoperatively and improved to 87 postoperatively. In IKDC system, 2 of 8 patients were group A and 6 were group B. Conclusion : Arthroscopic PCL reconstruction using achilles tendon allograft and posterior transseptal technique shows reliable stability, short operative time and minimizing donor site morbidity but needs more long term follow-up.

  • PDF

Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Park, Han-Chang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.

  • PDF

Reconstruction of Anterior Cruciate Ligament with Human Allograft (동종 이식건을 이용한 전방 십자 인대 재건술)

  • Suh Jeung-Tak;Cheon Sang-Jin;Lee Jung-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2000
  • Purpose : The purpose of this study is to evaluate the clinical outcomes and radiological changes after reconstruction of anterior cruciate ligament with human allograft. Material and Method : Authors analyzed 22 cases of anterior cruciate ligament allograft reconstruction which were done from January, 1995 to December, 1998 and could be followed up for a year or more. All cases were followed and reviewed in terms of anterior drawer test, Lachman test, Pivot shift test, radiographic examination, knee range of motion, and side-to-side difference of anteroior tibial translation using CA-4000 knee motion analyzer, and Lysholm knee scoring system. Result : The mean Lysholm knee score was 54 preoperatively and improved to 81 postoperatively by average of 27. The side-to-side difference of anterior tibial translation using CA-4000 knee motion analyser was less than 3 mm in 16 cases$(73\%)$, between 3 and 5 mm in 4 cases$(18\%)$, and greater than 6 min in 2 cases$(9\%)$. Average tibial tunnel enlargement was 1.5 mm, but there were not any osteoiysis or cystic formation along the tunnel and no relationship between tunnel enlargement and clinical outcome. Conclusion : Although this study had limited cases, clinical results of anterior cruciate allograft reconstruction were similar to those of reconstruction with autograft reported in the literatures. We think that allograft is an acceptable substitute fer autograft in anterior cruciate ligament reconstruction.

  • PDF