• Title/Summary/Keyword: 동적 초음파

Search Result 108, Processing Time 0.024 seconds

A Study on Mechanical Properties of Strand/Particle Composites (II) - Measuring of Young's Moduli and Estimating of Anisotropy Using an Ultrasonic Method - (스트랜드/파티클 복합체의 기계적 성질에 관한 연구(II) - 탄성률 측정 및 초음파법에 의한 이방성의 예측 -)

  • Kim, Yu-Jung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 2001
  • Composites with various layer constructions involving the ratio of S/P were produced from wood strands(S) and particles(P) (Cryptomeria japonica D.Don) to measure various Young's moduli and anisotropy by ultrasonics. As a result, static Young's moduli of composites were almost same as dynamic Young's moduli obtained from natural frequency. However, these were smaller than those evaluated from ultrasonic wave propagation velocity. The differences between propagation velocity of the parallel(${\parallel}$) and perpendicular(${\bot}$) in-plane direction resulted in a tendency of anisotropy. The tendency of anisotropy was larger in three-layer constructions than in seven-layer constructions. The differences of strand surface layers showed larger values than those of particle surface layers. Also, composites with higher weight ratio of strand had a tendency to propagate rapidly in each direction. In contrast to these results, the propagation velocity in the thickness direction had a tendency to propagate rapidly in composites with particle surface layers and the lower weight ratio of strand.

  • PDF

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

The Study on the Factors for Detection of Renal Stone on Ultrasound (초음파 검사에서 신장 결석의 검출 요인에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Purpose: Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. Material & Methods: The stone was place on sponge examined in a water bath with a 3.5MHz or 7.5MHz transducer(LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. Results: 1) Average echo level was 98 for low total gain(10 dB) and was 142 for high total gain(40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range(42 dB) and was 101 for high dynamic range(72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency(7.5 MHz) than low frequency(3.5 MHz) and it is not distorted. Conclusion: The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis.

  • PDF

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

Effect of Immediate Dynamic Balance Ability of Chronic Low Back Pain on Maitland's Manual Therapy (메이트란드 도수치료가 만성 요통환자의 즉각적인 동적 균형능력에 미치는 영향)

  • Hyong, In-Hyouk;Ha, Mi-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.207-215
    • /
    • 2009
  • There has been a diversity of therapeutic interventions for patients with chronic low back pain. However most of them have been focused on only pain. But the patients usually have a kind of structurally abnormal have fixed in lumbar vertebrae, which can decrease range of joint movement and, what is worse, reduce immediate dynamic balancing ability(IDBA). The reduced IDBA can increase the risk of injury and decrease coping ability in dangerous situation. So we introduced Maitland's manual therapy in this study in order to recover the IDBA in patients with chronic low back pain. Sixty-four patients diagnosed with chronic low back pain were included for the study. Among them, thirty-two patients(experimental group) were managed by Maitland's manual therapy, another thirty-tow patients(control group) were treated by physical science methods(H/P, TENS, U/S). Each group made use of highly reliable(0.81$\sim$0.96) star excursion balance test(SEBT) to compare the possible changes of IDBAs in two groups after treatment. In experimental group, IDBA has increased in forward, rightward, leftward, and backward, but in control group, not changed. According to the results, we concluded that Maitland's manual therapy is effective for increasing IDBA by making joints more flexible in lumbar vertebrae.

Measurement on the Natural Frequency of a Laminated Cantilever Microbeam using a Laser Interferometer (레이저 간섭계를 이용한 적층 마이크로 외팔보의 고유진동수 측정)

  • Kim, Yun-Young;Han, Bong-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • The natural frequency of a laminated cantilever microbeam was studied in the present investigation. The microbeam was made of quartz on a silicon chip, and its top and bottom surfaces were coated with thin(~30nm) gold films. An ultrasonic testing platform was employed to resonate the microbeam, and its time domain signal was optically measured. The natural frequency was quantified through the fast Fourier transform of the waveform, and the result showed good agreement with a theoretical estimation from the classical beam theory. This study is expected to provide a dynamic evaluation technique for micro/nanoscale materials and micromechanical structures.

An Experimental Study on the Ultrasonic Testing for Determinig Dynamic Soil Moduli (초음파를 이용한 흙의 동적계수측정에 관한 실험적 연구)

  • 민덕기;김문득
    • Geotechnical Engineering
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 1991
  • Determination of dynamic shear modulus of soil was made by measuring directly the velocity of ultrasonic shear waves transmitted through the specimen. The PUNDIT, a generator and detector of ultrasonic waves, has been used to measure the propagation velocity. Forty -six tests of compacted soil at seven different void ratios and seven varying degrees of saturation with four types of materials were made in this study. The primary importance in this study was the investigation of the relations among the para meters which influenced G-modulus, As a results of analysis, the dynamic shear modulus of soil tends to decrease with an increase of void ratio, and also it is affected by soil types. In case of using PUNDIT, the proper range of the specimen length is from 5cm to 8cm. And the degree of saturation doesn't affect the dyn- amic shear modulus of soil.

  • PDF

FCM Quantization based Fuzzy Stretching (FCM 양자화 기반 퍼지 스트레칭)

  • Lim, En-young;Kim, Nam-young;Kwon, Hee-young;Kim, Kwang-baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.59-62
    • /
    • 2021
  • 본 논문에서는 사다리꼴 형태의 소속 함수를 적용하여 스트레칭 하는 과정에서 상한과 하한을 FCM 기반 양자화 기법을 적용하여 동적으로 조정하는 퍼지 스트레칭 기법을 제안한다. 제안된 퍼지 스트레칭 기법은 FCM 기반 양자화 기법을 적용하여 각 클러스터를 생성하고 생성된 각 클러스터의 중심에 해당되는 명암도를 이용하여 사다리꼴 형태의 소속 함수의 구간을 설정한다. 그리고 설정한 구간 정보를 이용하여 스트레칭을 위한 상한과 하한을 구하여 영상을 스트레칭 한다. 제안된 FCM 양자화 기반 퍼지 스트레칭 기법의 성능을 분석하기 위해서 명암도 분포가 좁고 명암 대비가 낮은 결절종 초음파 영상과 컨테이너 영상을 대상으로 실험하였다. 실험 결과에서도 알 수 있듯이 기존의 히스토그램 스트레칭 기법과 삼각형 형태의 소속 함수를 적용한 퍼지 스트레칭 기법보다 명암 대비가 향상되었다. 결절종 초음파 영상에서는 결절종 영역과 그 외의 영역 간의 명암 대비가 뚜렷하게 나타나서 결절종 추출에 효과적인 것을 확인하였고 컨테이너 영상에서는 컨테이너 데미지를 추출하는데 필요한 컨테이너 굴곡선 등과 같은 특징이 다른 기법들에 비해 선명하게 나타났다.

  • PDF

Navigation Control of Mobile Robot based on VFF to Avoid Local-Minimum in a Corridor Environment (복도환경의 지역최소점 회피가 가능한 VFF 기반의 이동로봇 주행제어)

  • Jin, Tae-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.759-764
    • /
    • 2011
  • This paper deals with the method of using the amended virtual force field technique to avoidance the front environment(wall, obstacles etc.) in navigating by using the environmental informations recognized by a ultrasonic-ring and pan/tilt CCD camera equipped on a mobile robot. we will give an explanation for the robot system architecture designed and implemented in this study and a short review of existing techniques, since there exist several recent thorough books and review paper on this paper. It is proposed the rusult from the experimental run based on a virtual force field(VFF) method to support the validity of the aforementioned architecture of mobile service robot for local navigation and obstacle avoidance for autonomous mobile robots. We will conclude by discussing some possible future extensions of the project. The results show that the proposed algorithm is apt to identify obstacles in an indoor environments to guide the robot to the goal location safely.