• Title/Summary/Keyword: 동적 초음파

Search Result 108, Processing Time 0.02 seconds

Physical Properties of and Joint Distribution Within the Cheongju Granitic Mass, as Assessed from Drill-core and Geophysical Well-logging Data (시추 및 물리검층자료의 상관해석을 통한 청주화강암체의 물성 정보 및 절리 분포)

  • Lee, Sun-Jung;Lee, Cheol-Hee;Jang, Hyung-Su;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.15-24
    • /
    • 2011
  • To clarify the distribution of joints and fracture zones in the Cheongju granitic mass, we analyzed drill-core and geophysical well-logging data obtained at two boreholes located 30 m from each other. Lithological properties were investigated from the drill-core data and the samples were classified based on the rock mass rating (RMR) and on rock quality designation (RQD). Subsurface discontinuities within soft and hard rocks were examined by geophysical well-logging and cross-hole seismic tomography. The velocity structures constructed from seismic tomography are well correlated with the profile of bedrock depth, previously mapped from a seismic refraction survey. Dynamic elastic moduli, obtained from full waveform sonic and ${\gamma}-{\gamma}$ logging, were interrelated with P-wave velocities to investigate the dynamic properties of the rock mass. Compared with the correlation graph between elastic moduli and velocities for hard rock at borehole BH-1, the correlation points for BH-2 data showed a wide scatter. These scattered points reflect the greater abundance of joints and fractures near borehole BH-2. This interpretation is supported by observations by acoustic televiewer (ATV) and optical televiewer (OTV) image loggings.

A Case Study of Geumho River Basin for Integrated Flood Management (통합홍수관리를 위한 금호강유역 사례연구)

  • Ko, Jin-Seok;Choi, Eun-Hyuk;Keum, Do-Hun;Jee, Hong-Kee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.800-804
    • /
    • 2007
  • 전 세계에서 홍수로 인한 인명손실과 재산적 피해의 기록을 살펴보면 최근 몇 년 동안 꾸준히 증가하고 있다. 이로 인해서 홍수를 방어하기 위한 노력은 증가하게 되었다. 이로 인해 홍수터에서 인구집중과 개발로 인해 홍수방어를 위해서 막대한 투자가 필요하다. 이와 동시에 지속가능하고 효과적인 수자원 관리는 전체적인 접근방법이 요구되며, 사회와 경제발전과 생태계 보호 및 토지이용과 수자원 이용의 적절한 관리와 연결된 개념이 필요하다. 유역은 육지와 수계 사이의 많은 상호작용이 있는 동적인 시스템이다. 이러한 관점에서 유역을 간단한 고정된 지역적인 문제라고 생각하는 것보다 전체로서의 유역 기능을 개선하는데 노력이 필요하고 시도되어야 할 것이다. 통합홍수관리(IFM : Integrated Flood Management)는 홍수의 긍정적인 측면과 부정적인 측면을 고려한 새로운 접근방법이며, 홍수가 자원적 가치를 지닌 것이라고 생각하는 개념이다. 통합홍수관리의 특징은 홍수조절 대책의 적절한 혼합, 대책의 목적 및 형태(구조적 및 비구조적 대책), 단기간 및 장기간 대책 등의 대책들을 통합하는 것이다. 여기에는 전유역의 수문순환 관리, 통합 토지이용 및 수자원 관리, 최적 혼합대책의 적용 및 통합재해관리 적용 등이 있다. 홍수는 자연적인 수문학적 체계의 중요한 요소이며, 주요 수자원이기도 하다. 그리고 빈번한 홍수로 인해 제방을 넘어 홍수터를 점령한다. 이 결과로 상습 홍수범람지역은 점점 더 인구가 밀집되고 있고 홍수에 더 취약하게 된다. 그러므로 금호강유역에 발생한 홍수의 개요, 원인 및 결과에 대해서 살펴보고, 홍수관리대책과 실효성에 대해서 조사 분석하였다. 그리고 홍수가 발생한 후 홍수관리대책과 관리기술의 변화를 통합홍수관리의 개념에서 분석하였다.Jones matrix, which allows a new interpretation in the conversion efficiency of the thin-film optical waveguides.있다는 장점이 있었다. 따라서 소아에서 복막투석도관 수술 시 복강경적 방법을 이용하는 것이 효율적인 복막 투석을 위해 유용하다고 생각된다.상부 방광천자에 비해 민감도 59.5%(25/42), 특이도 86.6%(13/15)였고 위양성률 13.3%(2/15), 위음성률 40.5%(17/42) 로 정확도가 낮았다. 결론 : 소변을 가리지 못하는 영유아에서 요로 감염을 진단하기 위해서는 도뇨관 채뇨에 비해 초음파 감시하 치골상부 방광천자가 정확하고 안전한 채뇨법으로 권장되어야 한다고 생각한다.應裝置) 및 운용(運用)에 별다른 어려움이 없고, 내열성(耐熱性)이 강(强)하므로 쉬운 조건하(條件下)에서 경제적(經濟的)으로 공업적(工業的) 이용(利用)에 유리(有利)하다고 판단(判斷)되어진다.reatinine은 함량이 적었다. 관능검사결과(官能檢査結果) 자가소화(自家消化)시킨 크릴간장은 효소(酵素)처리한 것이나 재래식 콩간장에 비하여 품질 면에서 손색이 없고 저장성(貯藏性)이 좋은 크릴간장을 제조(製造)할 수 있다는 결론을 얻었다.이 있음을 확인할 수 있었다.에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며, 이는 한의학(韓醫學) 방제(方劑) 원리(原理)인 군신좌사(君臣佐使) 이론(理論)에서 군약(君藥)이 주증(主症)에 주(主)로 작용(作用)하는 약물(藥物)이라는 것을 밝혀주는 것이라고 사료(思料)된다.일전 $

  • PDF

Active Water-Level and Distance Measurement Algorithm using Light Beam Pattern (광패턴을 이용한 능동형 수위 및 거리 측정 기법)

  • Kim, Nac-Woo;Son, Seung-Chul;Lee, Mun-Seob;Min, Gi-Hyeon;Lee, Byung-Tak
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.156-163
    • /
    • 2015
  • In this paper, we propose an active water level and distance measurement algorithm using a light beam pattern. On behalf of conventional water level gauge types of pressure, float-well, ultrasonic, radar, and others, recently, extensive research for video analysis based water level measurement methods is gradually increasing as an importance of accurate measurement, monitoring convenience, and much more has been emphasized. By turning a reference light beam pattern on bridge or embankment actively, we suggest a new approach that analyzes and processes the projected light beam pattern image obtained from camera device, measures automatically water level and distance between a camera and a bridge or a levee. As contrasted with conventional methods that passively have to analyze captured video information for recognition of a watermark attached on a bridge or specific marker, we actively use the reference light beam pattern suited to the installed bridge environment. So, our method offers a robust water level measurement. The reasons are as follows. At first, our algorithm is effective against unfavorable visual field, pollution or damage of watermark, and so on, and in the next, this is possible to monitor in real-time the portable-based local situation by day and night. Furthermore, our method is not need additional floodlight. Tests are simulated under indoor environment conditions from distance measurement over 0.4-1.4m and height measurement over 13.5-32.5cm.

진공 측정 기술 개발 동향

  • Sin, Yong-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.3-3
    • /
    • 2010
  • 이번 성원에드워드 학술상 수상자 선정은, 진공기술의 중요성에 공감하고 진공기술 발전을 위한 노력을 독려하자는 진공학회 회원들의 의견을 모아주신 결과로 생각한다. 본 발표에서는 그동안 한국표준과학연구원에서 수행해 온 진공 기술 연구 및 산학연 협력 네트워크 활동을 소개하고자 한다. 진공기술은 진공 환경을 발생시키고 측정 제어하며, 만들어진 진공 환경 안에서 원하는 작업을 할 수 있도록 하는 기술을 말한다. 우리나라의 주력산업인 반도체 및 디스플레이의 경우 그 생산 설비의 1/3이상이 진공 장비이며 진공 공정을 통해 만들어진다. 때문에 우리나라에서는 주력 산업분야나 그 전후방 산업의 경쟁력 강화 측면에서 진공기술 개발 중요성이 아주 크다. 한국표준과학연구원은 국가 대표 측정 기관으로 국가 측정 표준을 확립하고 측정관련 과학기술을 연구개발하며 그 성과를 보급하여 경제발전과 과학기술발전, 그리고 삶의 질 향상에 기여하는 것을 임무로 하고 있다. 우리나라에서 진공 측정 표준에 대한 연구가 본격적으로 시작된 것은 1984년으로 불용 장비로 불하받은 펌프와 챔버, 그리고 차관으로 도입된 Capacitance Diaphragm Gauge 몇 개만으로 시작되었다. 지금은 발전을 거듭하여 초음파 간섭 수은주 압력계를 비롯하여 정적 팽창시스템, 동적 팽창 시스템 등 진공도 범위별 국가 표준기와 리크 표준기를 자체 개발 하여 국가 측정 표준을 확립하고 있다. 우리나라의 진공 표준 및 측정 능력은 국제기구인BIPM에서 실시하는 국가 측정능력 비교시험을 통해 세계 최고 수준으로 인정 받은 바 있으며 교정검사 등을 통해 산학연에 보급되고 있다. 진공 측정 및 표준기술을 토대로, 1999년부터 과학기술부와 산업자원부의 지원을 받아 산학연이 필요로 하는 펌프 계측기 부품 소재 및 공정 특성을 평가하기 위한 장치와 절차를 개발하였다. 이를 이용해 보급되는 기술 data는 진공부품 및 장비 국산화, 국산제품 신뢰성 제고, 검증부품 사용을 통한 장비 품질 향상, 독자적 장비 기술 확보, 생산품 품질관리 등에 쓰이고 있다. 한국 표준연구원 진공센터의 교정 및 시험 능력은 ISO 9001 인증 획득과 국제 전문가의 review를 거쳐, 국제기구 측정능력표에 등재되어 있어 국제적 신뢰도도 확보하고 있다. 정기적인 진공기술 교류회를 개최하고 진공기술 홈페이지를 운영 하는 등 산학연 정보 교류 및 협력 네트워킹 활성화를 위해 노력한 바 있으며 이 분야의 연구 성과는 '국가 우수 연구성과 100선'에 선정된 바 있고, 산업자원부 지정 '산학연 연계 우수사례' 첫 번째로 선정되기도 하였다. 2008년부터는 진공기술 교류회 등을 통한 네트워킹 활동으로 도출된 기술 수요에 따라 대기업과 중소기업 학교 연구소들과 함께 진공공정 실시간 측정 진단 기술과 센서 개발 연구, 그리고 이들 개발품의 신뢰성 검증 및 평가 기술 개발을 위해 노력하고 있다.

  • PDF

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

$^{99m}Tc-DTPA$ Galactosyl Human Serum Albumin Scintigyaphy in Mushiroom Poisoning Patient : Comparison with Liver Ultrasonography (버섯 중독 환자에서의 $^{99m}Tc-galactosyl$ human serum albumin (GSA) scintigraphy 소견 : 간초음파 소견과의 비교)

  • Jeong, Shin-Young;Lee, Jea-Tae;Bae, Jin-Ho;Chun, Kyung-Ah;Ahn, Byeong-Cheol;Kang, Young-Mo;Jeong, Jae-Min;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.254-259
    • /
    • 2003
  • $^{99m}Tc-galactosyl$ human serum albumin (Tc-GSA) is a radiopharmaceutical that binds to asialoglycoprotein receptors, which are specifically present in the hepatocyte membrane. Because these receptors are decreased in hepatic parenchymal damage, the degree of Tc-GSA accumulation in the liver correlates with findings of liver function test. Hepatic images were performed with Tc-GSA in patients with acute hepatic dysfunction by Amantia Subjunquillea poisoning, and compared with these of liver ultrasonography (USG). Tc-GSA (185 MBq, 3 mg of GSA) was injected intravenously, and dynamic images were recorded for 30 minutes. Time-activity curves for the heart and liver were generated from regions of interest for the whole liver and precordium. Degree of hepatic uptake and clearance rate of Tc-GSA were generated by visual interpretation and semiquantitative analysis parameters (receptor index : LHL15 and index of blood clearance : HH15). Visual assessment of GSA scintigraphy revealed mildly decreased liver uptake in all of subjects. The mean LHL15 and HH15 were 0.886 and 0.621, graded as mild dysfunction in 2, and mild to moderate dysfunction in 1 subject. In contrast, liver USG showed no remarkable changes of hepatic parenchyme. Tc-GSA scintigraphy was considered as a useful imaging modality in the assessment of the hepatic dysfunction.

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

$^{99m}Tc$-Tetrofosmin Scintimammography in Suspected Breast Cancer Patients: Comparison with $^{99m}Tc$-MIBI (유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin을 이용한 유방스캔: $^{99m}Tc$-MIBI와 비교)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.119-128
    • /
    • 2000
  • Purpose: The aim of this study was to investigate the diagnostic role of $^{99m}Tc$-Tetrofosmin in detection of breast cancer and compared with that of $^{99m}Tc$-MIBI. Material and Methods: Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Results: Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}Tc$-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-Tetrofosmin were 31,10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of $^{99m}Tc$-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin acintimammographies and its size was 0.5 cm. Conclusion: $^{99m}Tc-Tetrofosmin\;and\;^{99m}Tc-MIBI$ were non-invasive and useful in detection of breast cancer and $^{99m}Tc$-Tetrofosmin was comparable to the $^{99m}Tc$-MIBI in detection of primary breast cancer.

  • PDF