• Title/Summary/Keyword: 동적분포하중

Search Result 71, Processing Time 0.024 seconds

Development of Equations for Dynamic Design Loads of Sphere Type LNG Tank with Cylindrical Extension (원통 확장부를 갖는 구형 LNG 탱크의 동적 설계하중 산출식 개발)

  • Shin, Sang-Hoon;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.262-267
    • /
    • 2017
  • The number of shops needed for the fabrication of a sphere type cargo tank for an LNG carrier is proportional to the size of the tank to be constructed. Due to the limitations of facility investment, it is difficult to fabricate various size tanks with a perfectly spherical shape in the (factory). An efficient method of increasing the capacity of the cargo tank is to extend the conventional sphere type LNG tank vertically by inserting a cylindrical shell structure. In this study, equations for the dynamic pressure distribution due to horizontal acceleration are derived for a sphere type LNG tank with central extension. The derived equations can be easily applied to the design and structural assessment of a sphere type LNG tank with central extension. Furthermore, the results of this study can be combined with the static design loads previously reported by Shin & Ko [9], in order to establish a simplified analysis method which enables a precise initial estimate to be obtained, thereby obviating the need for a time consuming finite element analysis.

Dynamic Deformation Characteristics of Cohesionless Soils in Korea Using Resonant Column Tests (공진주시험을 이용한 국내 비점성토 지반의 동적변형특성)

  • 김동수;추연욱
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.115-128
    • /
    • 2001
  • 본 논문에서는 반복하중이나 지진하중을 받는 지반-구조물 시스템의 설계에 필수적인 변수인 전단탄성계수와 감쇠비에 대한 연구를 국내에 존재하는 비점성토 지반에 대하여 수행하였다. 국내 퇴적토지반 및 풍화토지반에서 채취된 자연시료와 입도분포를 조정하여 제작한 시료를 포함하여 총 60개의 시료에 대하여 20kPa에서 500kPa의 구속응력 범위에서 공진주 시험을 수행하고, 이를 조립질 사질토, 실트 및 실트질 모래, 풍화토의 3개의 그룹으로 나누어 결과를 정리하였다. 저변형률 영역의 변형특성인 최대전단탄성계수와 최소감쇠비에 대하여 구속응력의 영향을 확인하였다. 최대전단탄성계수를 예측하는 경험식을 3개의 그룹별로 제안하였다. 최소감쇠비는 구속응력에 따른 분포영역을 제시하였다. 세립분이 적은 조립질 사질토의 경우, 비선형 변형특성이 구속응력의 영향을 뚜렷이 받고 있어 이를 주요한 변수로 고려하여 대표곡선과 분포영역을 제안하였다. 구속응력의 영향을 적게 받는 실트 및 실트질 모래와 풍화토는 구속응력에 관계없이 대표곡선과 분포영역을 제안하였다. 제안된 각 시료의 대표곡선과 기존의 Vucetic-Dobry와 Seed-Idriss가 제안한 곡선과 비교하였다. 본 논문의 연구결과는 국내지반의 비점성토 지반에 대한 지진해석이나 동하중을 받는 시스템의 해석시 유용하게 사용될 것으로 판단된다.

  • PDF

Optimal Design of Viscoelastic Dampers in Building Frames by Eigenvalue Assignment (건축구조물에서 고유값 지전에 의한 점탄성 감쇠기의 최적설계)

  • Son, Dong-In;Lee, Sang-Hyun;Park, Ji-Hun;Kim, Jin-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.125-138
    • /
    • 2001
  • 고유진동수와 감쇠비는 지진이나 바람과 같은 동적 횡하중에 대해 구조물의 응답을 결정하는 주요한 특성이다. 본 연구는 지진하중에 대하여 목표응답 수준을 만족하는 구조물의 고유진동수와 감쇠비를 지정하고, 이 값을 실현하는 점탄성 감쇠기 파라미터의 처적분포를 구하는 설계방법을 제안한다. 여기서 지정할 고유진동수와 감쇠비는 목표응답 수준을 만족하는 여러 조합 중 설계조건과 원래 건물의 특성에 따라 결정될 수 있다. 제안한 설계방법은 점탄성 감쇠기의 감성 파라미터를 고유값의 기울기 정보를 바탕으로 분포시키므로 최적 위치와 크기에 대한 정보를 동시에 제공한다. 예제로서 평면 10층 전단 건물을 대상으로 최적설계를 수행하여 지정된 고유값을 실현하는 파라미터의 최적분포를 구하고 이를 통해 제안한 최적 설계의 특성을 확인하였다. 또한 더 나아가 3차원 일방향 비대칭 전단전물에 제안된 최적설계를 수행하여 그에 대한 적용가능성을 확인하였다.

  • PDF

Dynamic Stress Analysis on Impact Load in 2-Dimensional Plate (충격하중이 작용하는 평판의 동적 응력 해석)

  • 황갑운;조규종
    • Computational Structural Engineering
    • /
    • v.8 no.1
    • /
    • pp.137-146
    • /
    • 1995
  • Structural stress under shock or impact load is varied with the lapse of time and the structural stress is called stress wave. Propagating longitudinal stress wave is studied in a 2-dimensional plate. A finite element program for elastic stress wave propagation is developed in order to investigate the shape of stress field at time increment. The longitudinal stress wave is generated by unit step function. According to the finite element analysis results, the longitudinal stress wave propagates to the similar direction of impact load and the front of stress wave propagates with the same speed as analytic solution and the shape of stress field is similar to that of analytic solution. The shear wave is occurred after the longitudinal stress wave and declined at an angle of 45 degrees compared with longitudinal stress wave and the speed of shear wave is about a half of the longitudinal stress wave. The intensity of shear wave is larger than that of longitudinal stress wave.

  • PDF

A Study on the Equivalent Static Wind Load Estimation of Large Span Roofs (대스팬 지붕구조물의 등가정적 풍하중 산정에 관한 연구)

  • Lee, Myung-Ho;Kim, Ji-Young;Kim, Dae-Young;Kim, Sang-Dae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.1 s.19
    • /
    • pp.83-90
    • /
    • 2006
  • The GF(Gust Factor) method is usually used as a method to evaluate equivalent static wind loads for general structures. The GF method is performed on the assumption that the shape of the equivalent static wind load profile is typically similar to that of mean wind loads. The shape of fluctuating wind loads could be quite different with that of the mean wind loads in case of large-span structures. So, the effect of higher modes as well as first mode must be considered to evaluate the wind loads. In this study, the ACS (Advanced Conditional Sampling) method is suggested to evaluate of equivalent static wind loads after investigating about GF and LRC method. The An method ran derive effective static wind loads by combining wind pressures and inertia forces of a structure chosen at a maximum load effect. The maximum load effect is assessed with the time history analysis using pressure data measured in wind tunnel tests. Equivalent static wind loads evaluated using ACS, GF, and LRC methods are compared to verify the effectiveness of ACS method.

  • PDF

Dynamic Behavior and Resonance Reduction of Two-Span Continuous Bridges for Korean Train eXpress (KTX용 2경간 연속교량의 동적거동 및 공진감소)

  • Oh, Juwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.95-104
    • /
    • 2008
  • Dynamic behaviors of the two-span continuous bridge which is one of prototypes on Gyoung-Bu high-speed railway are analyzed and some methods for reducing the resonance of the bridge are proposed. The bridge is modeled as a two-span continuous beam and the load is a vehicle of TGV-K (2p+18T) with length of 380.15 meter traveling on the railway bridge at some constant velocity. The equations governing the dynamic behaviors of the bridge are partial differential equations produced by using a system with distributed mass and elasticity. The analysis of the governing equations is performed by the mode superposition method which has modal coordinates solved by Duhamel's integral. Without considering the train velocity the dynamic reponses can be greatly reduced at some special lengths of bridge. It is different from the results of simple bridges researched so far. When the dynamic responses increase rapidly to make a resonance phenomenon depending on the train velocities, the several methods are proposed to deduce the resonance.

Modal Combination Method for Prediction of Story Earthquake Load Profiles (층지진하중분포 예측을 위한 모드조합법)

  • Eom, Tae-Sung;Lee, Hye-Lin;Park, Hong-Gun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.65-75
    • /
    • 2006
  • Nonlinear pushover analysis is used to evaluate the earthquake response of building structures. To accurately predict the inelastic response of a structure, the prescribed story load profile should be able to describe the earthquake force profile which actually occurs during the time-history response of the structure. In the present study, a new modal combination method was developed to predict the earthquake load profiles of building structures. In the proposed method, multiple story load profiles are predicted by combining the modal spectrum responses multiplied by the modal combination factors. Parametric studies were performed far moment-resisting frames and walls. Based on the results. the modal combination factors were determined according to the hierarchy of each mode affecting the dynamic responses of structures. The proposed modal combination method was applied to prototype buildings with and without vertical irregularity. The results showed that the proposed method predicts the actual story load profiles which occur during the time-history responses of the structures.

The Effect of Higher Vibration Modes on the Design Seismic Load (고차진동모드의 영향을 고려한 층지진하중)

  • 이동근;신용우
    • Computational Structural Engineering
    • /
    • v.3 no.4
    • /
    • pp.123-132
    • /
    • 1990
  • In current practice of earthquake resistant design the equivalent lateral force procedure is widely used because of its simplicity and convenience. But the equivalent lateral force procedure is derived based on the assumptions that the dynamic behavior of the structure is governed primarily by the fundamental vibration mode and the effect of higher modes is included in an approximate manner. Therefore the prediction of dynamic responses of structures using the equivalent lateral force procedure is not reliable when the effect of higher vibration modes on the dynamic behavior is significant. In this study, design seismic load which can reflect the effect of higher vibration modes is proposed from the point of view of proper assessment of story shears which have the major influence on the design moment of beams and columns. To evaluate the effect of higher modes, differences between the story force based on the equivalent lateral force procedure specified in current earthquake resistance building code and the one based on modal analysis using design spectrum analysis are examined. From these results an improved design seismic load for the equivalent lateral force procedure which can reflect the effect of higher vibration modes are proposed.

  • PDF

Understanding the Asymptotic Convergence of Domain of Attraction in Extreme Value Distribution for Establishing Baseline Distribution in Statistical Damage Assessment of a Structure (통계적 구조물 손상진단에서 기저분포 구성을 위한 극치분포의 점근적 수렴성 이해)

  • Kang, Joo-Sung;Park, Hyun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.231-242
    • /
    • 2009
  • The baseline distribution of a structure represents the statistical distribution of dynamic response feature from the healthy state of the structure. Generally, damage-sensitive dynamic response feature of a structure manifest themselves near the tail of a baseline statistical distribution. In this regard, some researchers have paid attention to extreme value distribution for modeling the tail of a baseline distribution. However, few researches have been conducted to theoretically understand the extreme value distribution from a perspective of statistical damage assessment. This study investigates the asymptotic convergence of domain of attraction in extreme value distribution through parameter estimation, which is needed for reliable statistical damage assessment. In particular, the asymptotic convergence of a domain of attraction is quantified with respect to the sample size out of which each extreme value is extracted. The effect of the sample size on false positive alarms in statistical damage assessment is quantitatively investigated as well. The validity of the proposed method is demonstrated through numerically simulated acceleration data on a two span continuous truss bridge.

A Property of Seismic Response with Log-normal Distribution at SDOF Structure (단자유도계 구조물의 로그정규분포 지진응답 특성)

  • Chung, Youn-In;Kim, Koon-Chan;Chey, Min-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.303-308
    • /
    • 2019
  • This study suggests a method for deriving earthquake response based on log-normal distribution in order to obtain realistic and reliable probability and statistical seismic response of structures. The development of three earthquake suites were presented, with a brief description of 2%, 10%, and 50% in 50 years probability of exceedance according the USGS Los Angeles probabilistic seismic hazard maps. In order to analyze the basic dynamic behavior, a Single-Degree-of-Freedom (SDOF) structure was selected and the seismic response spectrum representing the response of each natural period was plotted. Overall, the mean response values presented through the log-normal distribution is lower than the standard normal distribution. Thus, it is considered that the former method can be provided as the effective cost on performance-based seismic design more than the latter one.