• Title/Summary/Keyword: 동적모드

Search Result 573, Processing Time 0.031 seconds

Study on Deriving the Buckling Knockdown Factor of a Common Bulkhead Propellant Tank (공통격벽 추진제 탱크 구조의 좌굴 Knockdown Factor 도출 연구)

  • Lee, Sook;Son, Taek-joon;Choi, Sang-Min;Bae, Jin-Hyo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.3
    • /
    • pp.10-21
    • /
    • 2022
  • The propellant tank, which is a space launch vehicle structure, must have structural integrity as various static and dynamic loads are applied during ground transportation, launch standby, take-off and flight processes. Because of these characteristics, the propellant tank cylinder, the structural object of this study, has a thin thickness, so buckling due to compressive load is considered important in the cylinder design. However, the existing buckling design standards such as NASA and Europe are fairly conservative and do not reflect the latest design and manufacturing technologies. In this study, nonlinear buckling analysis is performed using various analysis models that reflect initial defects, and a method for establishing new buckling design standards for cylinder structures is presented. In conclusion, it was confirmed that an effective lightweight design of the cylinder structure for common bulkhead propulsion tank could be realized.

A Study of Real-time Service on Retransmission Slot in LR-WPAN (LR-WPAN에서 재전송 슬롯 기반 실시간 서비스 연구)

  • Cho, Moo-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.5
    • /
    • pp.19-27
    • /
    • 2010
  • In this paper, we propose a scheme for real-time data retransmission in LR-WPAN to support the required QoS even in the severe channel error environments. In IEEE 802.15.4a, as the user data rate is supported up to 850Kbps, the real-time streaming data can be transferred more easily. In this research, we study the beacon-enabled mode in IEEE 802.15.4 LR-WPAN standard. In the proposed scheme, special slots are dynamical1y assigned for retransmission of the packet that fails during a real-time data service, and in the severe channel error environments a time diversity is acquired. Analytical results show that the proposed scheme is more robust and achieves a much higher throughput than the previous protocol in LR-WPAN.

A Study of Voice Data Retransmission in LR-WPAN (LR-WPAN에서 음성 데이터 재전송 연구)

  • Cho, Moo-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.33-41
    • /
    • 2009
  • In this paper, we propose a scheme for voice data retransmission in LR-WPAN to support the required QoS even in the severe channel error environments. In IEEE 802.15.4a, as the user data rate is supported up to 850Kbps, the voice streaming data can be transferred more easily. In this research, we study the beacon-enabled mode in IEEE 802.15.4 LR-WPAN standard with 250Kbps data rate. In the proposed scheme, special slots are dynamically assigned for retransmission of the packet that fails during a voice service, and in the severe channel error environments a time diversity is acquired. Analytical results show that the proposed scheme is more robust and achieves a much higher throughput than the previous protocol in LR-WPAN.

Design and Analysis of Composite Reflector of High Stable Deployable Antenna for Satellite (위성용 전개형 고안정 반사판 안테나 복합재 주반사판 설계 및 해석)

  • Dong-Geon Kim;Kyung-Rae Koo;Hyun-Guk Kim;Sung-Chan Song;Seong-Cheol Kwon;Jae-Hyuk Lim;Young-Bae Kim
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.230-240
    • /
    • 2023
  • The deployable reflector antenna consists of 24 unit main reflectors, and is mounted on a launch vehicle in a folded state. This satellite reaches the operating orbit and the antenna of satellite is deployed, and performs a mission. The deployable reflector antenna has the advantage of reduce the storage volume of payload of launch vehicle, allowing large space structures to be mounted in the limited storage space of the launch vehicle. In this paper, structural analysis was performed on the main reflector constituting the deployable reflector antenna, and through this, the initial conceptual design was performed. Lightweight composite main reflector was designed by applying a carbon fiber composite and honeycomb core. The laminate pattern and shape were selected as design variables and a design that satisfies the operation conditions was derived. Then, the performance of the lightweight composite reflector antenna was analyzed by performing detailed structural analysis on modal analysis, quasi-static, thermal gradient, and dynamic behavior.

Estimating Tensile Force of Hangers in Suspension Bridges Using Frequency Based SI Technique : III. Experimental Verification (진동기반의 SI 기법을 이용한 현수교 행어의 장력 추정 : III. 실험적 검증)

  • Jang, Han Teak;Kim, Byeong Hwa;Park, Taehyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.215-222
    • /
    • 2008
  • This paper introduces an experimental verification of a tension estimation method based on system identification approach for a double hanger system on a suspension bridge. A laboratory model of such double hanger system has been made for this study. Total nine cases of the vibration tests have been conducted with respect to three levels of applied tension and three cases of the location of clamp. For a set of the collected acceleration response data, modal analysis has been followed in order to extract the natural frequencies and mode shapes of the selected cable systems. For the extracted modal parameters, the existing tension estimation methods based on the string theory and axially loaded beam theory have been firstly applied to estimate the tensile force on the double hanger cable system. Next, the tensile force on cables has been estimated by the system identification approach. It is seen that the errors in the tension estimation using the frequency-based system identification technique are about 3% for all cases while the estimation error using the existing method is up to 53.1%.

Evaluation of Structural Performance of Multi-tiered Roof Korean Traditional Timber Building Daeungbojeon Hall of Magoksa Temple Under Vertical Load (중층 전통 목조건축 마곡사 대웅보전의 수직하중에 대한 구조성능 평가)

  • Yeong-Min Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.1
    • /
    • pp.17-24
    • /
    • 2024
  • This paper assesses the structural performance of the Daeungbojeon Hall of Magoksa in Gongju, a representative multi-tiered roof traditional timber structure from the Joseon Dynasty, under vertical loads. Employing midas Gen, a structural analysis software, we developed a three-dimensional analysis model closely resembling the actual structure. Static analysis was employed to evaluate the safety and serviceability of the main vertical and horizontal members under vertical loads. While all members met the safety and serviceability criteria, structural weaknesses were identified in the Daelyang of the lower floor, particularly as a transitional beam, necessitating improvement. For the evaluation of dynamic behavior characteristics, eigenvalue analysis was conducted, assuming a relative rotational stiffness of 5% at the main joints. The natural period was determined to be 1.105 seconds, placing it within the category of a Hanok of similar size. The first mode manifested as a translational movement in the forward and backward direction of the building.

A study on the noise reduction method of transformer using harmonic response analysis (조화응답해석을 이용한 변압기의 소음저감 방법에 관한 연구)

  • Chang-Seop Kim;Won-Jin Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.277-284
    • /
    • 2024
  • This study proposes a method to predict noise reduction based on noise-reduction measures, using harmonic response analysis, for transformer design. The dynamic elastic coefficients of the components comprising the actual transformer were determined by manufacturing the materials of the transformer components into simple-shaped specimens, followed by a comparison of the modes between the experiments and the analyses. A finite element model of the transformer was implemented, and harmonic response analysis was performed by deriving the exciting force of the transformer. Subsequently, the theoretical sound power level of the transformer was derived from the results of the harmonic response analysis. Finally, noise reduction measures were established, and the noise reduction amounts were compared between the experiments and the analyses, before and after applying the measures. Through the comparison and analyses of the noise reduction measures, it was confirmed that the trends in the experiments and analyses matched.

Collapse Modes of Steel Ordinary Concentrically Braced Frames According to Unbalanced Forces (불균형력에 따른 철골보통중심가새골조의 붕괴모드)

  • Park, Jin-Young;Kim, Seo-Yeon;Hong, Suk-Jae;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • The KBC2009 first introduces the requirements about vertical unbalanced forces into the design for steel ordinary concentrically braced frames(steel OCBFs), which forces them to easily meet the target seismic performance, called as the life safety performance objective under design based earthquakes(DBEs) pursuing in the KBC2009. However, there is little information on the effects of vertical unbalanced forces to the collapse prevention performance objective under maximum considered earthquakes(MCEs) which is another target seismic performance level implicitly prescribed in ASCE 7-10. It is valuable that the collapse capacities of steel OCBFs designed according to the KBC2009 are investigated. In this paper, the collapse modes of inverted V shaped steel OCBFs excited by MCEs are investigated. The prototype buildings of 5 story steel OCBFs are designed with different site conditions and three types of unbalanced forces are considered in the design stages. The prototype buildings are evaluated their seismic performances and collapse modes by nonlinear static analyses and nonlinear dynamic analyses. Analysis results show that the unbalanced forces significantly affect the seismic performance of the prototype buildings and proper considerations of unbalanced forces are required to achieve the desirable collapse mode and the collapse prevention performance objective.

A Study on the Changes of Accommodative Function in Respect to the Viewing Angle (주시각도에 따른 조절기능의 변화)

  • Lee, Hark-Jun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: The purpose of this study was to examine the relationship between the accommodative facility, blink rate and accommodative lag according to the change of angles of main viewpoint of near distance worker and study an appropriate viewing angle that mitigates asthenopia, such as headaches or eye fatigue accompanied when reading and staring at the computer or TV for a long time. Methods: Total of 27 people including 12 male university students and 15 female university students in the age of 20 to 36 with frequent near distance works, such as computers, were selected to study the accommodative facility, the blink rate and the accommodative lag in accordance with the change of viewing angles of the near distance workers. The refraction error was corrected completely and the phoropter was shifted to near distance mode to locate the near distance indication at 40 cm. The accommodative facility and the blink rate were measured for one minute at each viewing direction of $40^{\circ}$ downward, $20^{\circ}$ downward, horizontal, and $20^{\circ}$ upward directions based on the horizontal line and the accommodative lag was measured in dynamic retinoscopy using retinoscope. Results: As a result, when the main viewpoint was moved on upper direction from the $40^{\circ}$ below, the accommodative facility was reduced and the blink rate and the accommodative lag were increased so their eyes became dry and the accommodation response was reduced. Conclusions: In near distance works, the eye fatigue level can be minimized by locating a book or a computer screen $40^{\circ}$ below than the horizontal direction.

  • PDF

Adaptive Design Techniques for High-speed Toggle 2.0 NAND Flash Interface Considering Dynamic Internal Voltage Fluctuations (고속 Toggle 2.0 낸드 플래시 인터페이스에서 동적 전압 변동성을 고려한 설계 방법)

  • Yi, Hyun Ju;Han, Tae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.251-258
    • /
    • 2012
  • Recently, NAND Flash memory structure is evolving from SDR (Single Data Rate) to high speed DDR(Double Data Rate) to fulfill the high performance requirement of SSD and SSS. Accordingly, the proper ways of transferring data that latches valid data stably and minimizing data skew between pins by using PHY(Physical layer) circuit techniques have became new issues. Also, rapid growth of speed in NAND flash increases the operating frequency and power consumption of NAND flash controller. Internal voltage variation margin of NAND flash controller will be narrowed through the smaller geometry and lower internal operating voltage below 1.5V. Therefore, the increase of power budge deviation limits the normal operation range of internal circuit. Affection of OCV(On Chip Variation) deteriorates the voltage variation problem and thus causes internal logic errors. In this case, it is too hard to debug, because it is not functional faults. In this paper, we propose new architecture that maintains the valid timing window in cost effective way under sudden power fluctuation cases. Simulation results show that the proposed technique minimizes the data skew by 379% with reduced area by 20% compared to using PHY circuits.