• Title/Summary/Keyword: 동시 성형

Search Result 274, Processing Time 0.032 seconds

A Study on Properties of Waste Wood-Plastic Composite Panels (폐목재-플라스틱을 이용한 복합패널의 특성 연구)

  • Mun, Kyoung-Ju;Choi, Nak-woon;Choi, San-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.85-94
    • /
    • 2004
  • Waste wood-plastic composite panels are made on different hot press molding conditions, and tested for apparent density, water absorption, expansion in thickness and flexural strength. From the test results, regardless of molding temperature and molding time, the apparent density of the composite panels is increased with an increase in the molding pressure, while their water absorption is decreased with an increase in the molding pressure. The flexural strength of the composite panels is markedly increased with increasing molding pressure, molding temperature and molding time, and tends to become nearly constant at a molding temperature of $120^{\circ}C$ and a molding time of 15min.

  • PDF

Early Changes of Left Ventricular Geometry and Function after Surgical Ventricular Restoration and Mitral Valve Annuloplasty: Magnetic Resonance Imaging (외과적 심실 복원과 승모판 고리성형 후 좌심실 형태와 기능의 초기 변화: 자기공명영상)

  • Choi, Byoung-Wook;Chang, Byung-Chul;Kim, Young-Jin;Hur, Jin;Lee, Hye-Jeong;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Purpose : We sought to determine the early change of ventricular geometry and function after concomitant surgeries of modified Dor procedure and mitral valve annuloplasty by using magnetic resonance imaging. Materials and Methods : We enrolled 21 patients with dilated heart failure who underwent modified Dor procedure (n=8), mitral valve annuloplasty (n=6), or both surgeries (n=7). Cine MRI was used to assess left ventricular dimensions and function before and after surgery. We measured the left ventricular end-diastolic and end-systolic volumes and the dimensions of the left ventricular long-axis and short-axis. Left ventricular stroke volume, ejection fraction, and sphericity index were calculated from these measurements. These parameters were analyzed and compared between three different surgery groups to explain the combined effect of the concomitant surgeries. Results : MRI was performed within average $12\;{\pm}\;15$ days (range 1-58 days) before and $38\;{\pm}\;50$ days (range 7- 231 days) after the surgery. The patients who underwent concomitant surgeries had more profound enlargement of left ventricle and decreased contractility prior to surgery than those in the patients who underwent single surgical procedure. Left ventricular end-diastolic volume and endsystolic volume significantly decreased in all patients regardless of surgery type after surgery. Ejection fraction significantly increased only in the patients who got modified Dor procedure without mitral valve annuloplasty (25.4% to 40.7%). Sphericity index increased in patients with modified Dor procedure but decreased in patients with mitral valve annuloplasty (0.65 to 0.78 vs. 0.75 to 0.65). In the patients who underwent concomitant surgeries showed no significant change in sphericity index after surgery. Conclusion : The early change of the left ventricular geometry and function after the concomitant surgeries with modified Dor procedure and mitral valve annuloplasty in patients with dilated heart failure includes a marked reduction in left ventricular volume and in stroke volume. The shape of the left ventricle does not change because the effect of sphericity index decrease from mitral valve annuloplasty is counteracted by the effect of sphericity index increase from modified Dor procedure. Improvement of left ventricular ejection fraction is not the early change after the concomitant surgeries.

  • PDF

Treatment of a Case with Dysphonia due to Posterior Glottic Chink using Arytenoid Adduction and Type I Thyroplasty (피열연골내전술과 제1형 갑상연골성형술을 이용한 성문후부부전에 의한 발성장애의 치료 1례)

  • 최홍식;최재진;김광문
    • Proceedings of the KSLP Conference
    • /
    • 1994.06b
    • /
    • pp.87-87
    • /
    • 1994
  • 편측 성대마비에 의한 부전의 수술적 치료로는 그 동안 테플론주입에 의한성대내측전위술, 제1형 갑상연골성형술, 또는 피열연골내전술 등이 이용되었으며, 성대부전이 심하거나 성대높이에 차이가 있을 때는 제1형 갑상연골성형술 등에 비해 피열연골내전술이 좋은 결과를 보이는 것으로 보고되고 있다 그러나, 성대의 움직임은 있으면서 뒷쪽에 심한 성대부전(posterior glottic chink)을 보이는 경우에는 아직은 특별한 수술적인 방법이 없는 바, 저자들은 갑상선 부분절제술 후에 생긴 양쪽성대의 움직임은 있으면서 성문 뒷쪽에 심한 부전을 보인 발성장애 환자 1례에서 제1형 갑상연골성형술과 동시에 피열연골내전술을 시행하여 좋은 결과를 얻었기에 보고하는 바이다. (중략)

  • PDF

Management of Premaxilla in Patient with Bilateral Complete Cleft Lip and Palate (양측성 완전 구순구개열 환자에서 전상악골에 대한 처치)

  • Lee, Ui-Lyong;Choung, Pill-Hoon
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.12 no.2
    • /
    • pp.57-64
    • /
    • 2009
  • 전방으로 심하게 돌출된 전상악골로 인하여 구순성형술 및 비성형술의 결과가 악화 될 수 있다. 따라서 변위된 전상악골의 이상적인 위치로 재위치 시키려는 다양한 노력이 시도되어 왔다. 에디오피아와 같은 개발도상국에서는 어른이 되어서도 수술을 받지 못하는 구순구개열 환자가 많이 있다. 성인이 될 때까지 수술받지 못한 양측성 완전 구순구개열 환자에서는 근육, 골, 피부, 점막의 연속성이 없어서 전상악골이 심하게 전방으로 혹은 하방, 좌우측으로 변위된 경우가 대부분이다. 이 경우 구순성형술이 거의 불가능하며, 시도된다 할지라도 돌출된 전상악골 때문에 양쪽 구륜근을 봉합하여 주기가 대단히 어렵다. 따라서 이상적인 결과를 얻기 위해서는 구순성형술 전 혹은 동시에 전상악골의 재위치 술식이 필수적이다. 저자는 한국국제협력단에서 국제협력의사로 선발되어 에디오피아에서 30 개월간 근무하였다. 그 동안 다양한 양측성 완전 구순구개열 환자에서 전상악골의 재위치 술식을 경험하였다. 저자가 경험한 전상악골의 재위치 술식(전상악골의 재위치와 골이식술 동시 시행, 전상악골의 재위치와 구개열 성형술 동시시행)에 대하여 문헌고찰과 함께 보고하고자 한다.

  • PDF

Cure Monitoring of Composite Laminates Using Fiber Optic Sensors (광섬유 센서를 이용한 복합재료 적층판의 성형 모니터링)

  • Gang, Hyeon-Gyu;Gang, Dong-Hun;Park, Hyeong-Jun;Hong, Chang-Seon;Kim, Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.59-66
    • /
    • 2002
  • In this paper, we present the simulataneous monitoring of the strain and temperature during cures f various composite laminates using fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPI) hybrid sensors. Three types of graphite/epoxy composite were used : a undirectional laminate, a symmetric cross-ply laminate, and a fabric laminate. Two FBG/EFPI hybrid sensors were embedded in each laminate at different directions and different locations. We performed the real time monitoring of fabrication strains and temperatures at two points within the composite laminates during cure process in an autoclave. Throuhg these experiments, FBG/EFPI sensors proved to be an efficient choice for smart cure monitoring of composite structures.

A MODIFICATION OF THE MICHELET TECHNIQUE FOR SLIDING HORIZONTAL OSTEOTOMY;A CASE REPORT (MICHELET 테크닉의 변형을 이용한 이부성형술의 치험례)

  • Lee, Jin-Gew;Davis, Isaac E.;Swift, James Q.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 1994
  • 앞 턱 부위가 짧고 후방으로 위치해 있을 때 턱의 높이를 증가시키고 전방으로 돌출시키는 축조 이부성형술의 방법으로는, 매식체 삽입술, 골 절단술, 골 절제술 또는 이들을 동시에 시행하는 혼합술등이 행해져 왔다. 그러나 매식체 삽입술에서는 감염 또는 매식체의 유동성 등의 합병증의 발병이 빈발하고 매식체의 밑 부위에 골이 흡수된다든지 연조직의 변화를 예측하기 어렵다든지 하는 복잡한 문제점들이 종종 보고되고 있다. 따라서 매식체를 이용하지 않는 골 절단술이나 골 절제술만을 이용한 다양한 방법의 이부성형술이 많이 시행되고 있다. 하악골이 전후방 관계로 발육부전인 환자에게 양측 하악지 시상분할술을 시행하여 전방 이동시킨 후 앞 턱의 위치를 좀더 개선하기 위하여 $Michel{\'{e}}t$ 테크닉의 변형법을 이용한 이부성형술을 추가로 시행하였다. 이 방법의 이부성형술은 턱의 수직적, 수평적 길이를 증가시키기 위하여 하악결합면 부위에 장부와 장붓구멍 모양을 한 골 절단술을 시행하고 광범위한 연조직경을 보존하여 골편으로의 혈류 차단을 최소화하였으며 나사를 이용한 견고한 고정을 용이하게 하였다. 이 술식은 턱을 수직적으로 증가시킬 때 두 골편 사이의 공간에 골 이식을 시행할 필요가 없으며, 금속판을 이용하지 않아도 정확한 위치에 골편을 고정하기가 용이하고, 또한 고정용 나사가 향후 골형성 부위에 위치하게 된다는 장점을 경험하게 되어 이에 한 증례를 보고하는 바이다.

  • PDF

Performance exploration on the number of register for Coarse grained reconfigurable array processor (재구성형 프로세서 성능과 레지스터와의 상관 관계 탐구)

  • Kim, Yongjoo;Heo, Ingoo;Yang, Seungjun;Lee, Jongwon;Choi, Youngkyu;Paek, Yunheung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.22-25
    • /
    • 2010
  • 재구성형 프로세서는 파워를 적게 사용하면서도 높은 성능을 낼 수 있는 프로세서이다. 재구성형 프로세서는 하드웨어에 최대한 많은 계산 자원을 넣으면서도 구조를 최대한 간단하게 하여 저전력 소모와 고성능을 동시에 추구하였다. 하지만 구조를 최대한 간단히 하는 과정에서 프로그램의 수행을 관리하는 많은 하드웨어 로직이 빠지게 되었는데, 이 부분은 컴파일러에서 코드를 생성할 때 스케쥴링과 수행 순서까지 정해지도록 소프트웨어적 관점에서 처리하기로 하였다. 이를 사용하기 위해 컴파일러는 입력된 프로그램을 분석하고 재구성형 프로세서에서 수행될 수 있는 형태로 코드를 각 계산자원에 매핑하는 작업을 수행해 주어야 한다. 재구성형 프로세서의 레지스터는 이 매핑 과정에서 데이터의 전달을 위해서 주로 사용되게 된다. 이 논문에서는 다양한 멀티미디어 응용 프로그램을 사용하여 멀티미디어 환경에서 재구성형 프로세서가 사용될 때 레지스터 개수가 성능에 미치는 영향을 제시한다.

TREATMENT OF CLEFT PALATE;SIMULTANEOUS USE OF PALATOPLASTY AND PHARYNGOPLASTY (구개열의 치료;구개성형술과 인두피판성형술의 동시 사용)

  • Kim, Young-Kyun;Yeo, Hwan-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.384-389
    • /
    • 1994
  • A female child with unilateral midpalatal cleft was successfully treated by Wardill V-Y pushback palatal flap and superiorly based pharyngeal flap simultaneously. The advantages of this method are to prepare the favorable background of postoperative speech correction and additional nasal lining. We can try this simultaneous operation in delayed cleft palate repair.

  • PDF

Numerical study on the effect of the PET bottle thickness difference for blow molding process conditions (블로우 성형 공정 변수가 PET 용기의 두께 편차에 미치는 영향에 관한 수치해석 연구)

  • Kim, Jeong-soon;Kim, Jong-duck
    • 대한공업교육학회지
    • /
    • v.34 no.2
    • /
    • pp.321-330
    • /
    • 2009
  • This study presents the blow molding of injection stretch-blow molding process for PET bottle. The numerical analysis of the blow molding of PET bottle is considered in this paper using CAE with a view to minimize the thickness difference. In order to determine the design parameters and processing conditions in blow molding, it is very important to establish the numerical model with physical phenomenon. In this study, a shell model with thickness has been introduced for the purpose and blow simulations with 3-type blow process condition are carried out. The simulations resulted in the thickness distribution in good agreement with the physical phenomenon. Also, from the result of numerical analysis, we appropriately predicted the thickness distribution along the PET bottle wall and Using the result of numerical analysis we apply the preform design and blow molding process condition for optimization.

Concomitant Operation of Pulmonary Resection and Redo Double Valve Replacement -1 case report- (폐절제술과 이중판막재치환술 동시수술 -1예 보고-)

  • 조중구;김공수;서연호
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.876-879
    • /
    • 2004
  • Patients with concomitant surgical diseases of the heart and lungs are a therapeutic challenge to cardiothoracic surgeons. A 59-year-old woman underwent right middle lobectomy for lung cancer and redo double valve replacement with tricuspid annuloplasty simultaneously. Concomitant operation is a safe procedure and might allow prompt correction of both conditions, thereby sparing the patient a second major thoracic procedure with its attendant risks.