• Title/Summary/Keyword: 동상 방지층

Search Result 41, Processing Time 0.02 seconds

Development of Model for Structural Evaluation of Anti-Freezing Layer (동상방지층의 구조적 평가를 위한 모형 개발)

  • Lee, Moon-Sup;Heo, Tae-Young;Park, Hee-Mun;Kim, Boo-Il
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.25-32
    • /
    • 2012
  • The thickness of anti-freezing layer has been empirically determined using the frost depth obtained from the freezing index and has not been generally considered as a structural layer in pavement design procedure. In fact, the anti-freezing layer makes a role in structural layer and enables to reduce the total thickness of pavement system. The objective of this study is to develop the statistical regression model for evaluating the structural capacity of anti-freezing layer using Falling Weight Deflectormeter(FWD) test data in asphalt pavements. The FWD testing was conducted at the embankment, cutting, and boundary area of various test sections to estimate the structural capacity of anti-freezing layer in different foundation condition. It is observed from this testing that the center deflections of pavement structure with anti-freezing layer are smaller than those without anti-freezing layer ranging from 0.4 to 82.6%. To determine the variables of statistical model, the correlation study has been conducted between various FWD deflection indexes and the anti-freezing layer thickness. It is found that the ${\Delta}BDI$(%)(${\Delta}Basin$ Damage Index(%)) is highly correlated with anti-freezing layer thickness. The ${\Delta}BDI$(%) model were developed for evaluating structural capacity of anti-freezing layer using linear mixed-effect models.

Estimation of the Mean CBR for the Subgrade Layer Including the Anti-Frost Layer (동상방지층을 포함한 노상층의 평균 CBR 산정에 관한 연구)

  • Min, Gyeong-Ho;Lee, Cheo-Keun;Heo, Yol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 2002
  • Generally, the California Bearing Ratio(CBR) for the material of subgrade is estimated without considering the anti-frost layer into the subgrade layer when pavements are designed. A pavement structure is determined according to the CBR. However, recently the design method taking the anti-frost layer into the subgrade layer is getting prevail. It makes the top of the subgrade layer strengthen and the thickness of the road pavement structure decreased. By the way, some confusion may be caused because theoretically the general equation for the mean CBR to combine the material of the subgrade layer and anti-frost layer have not been developed well. In this paper, laboratory and field CBR tests were performed to estimate of the mean CBR for the subgrade layer including the anti-frost layer. From the basis of the test results, modified equation which is calculating the mean CBR of the subgrade layer has been proposed. Finally, economical efficiency was considered by comparing the pavement thickness with the road pavement design using CBR of the subgrade layer alone and the road pavement design using the mean CBR including the anti-frost layer.

  • PDF

Structural assessment of Anti-Freezing Layer with use of Falling Weight Deflectormeter Deflection (Falling Weight Deflectormeter를 이용한 동상방지층의 구조적 특성 분석)

  • Lee, Moon-Sup;Kim, Boo-Il;Jeon, Sung-Il;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • Until now, the thickness design of anti-freezing layer has been empirically conducted using the frost depth determined from the freezing index. This approach cannot consider the structural properties of anti-freezing layer, which can cause the over-design of pavement structure. This paper presents results of structural evaluation of anti-freezing layer using the Falling Weight Deflectormeter (FWD) deflections. The FWD testing was directly conducted on top of the subbase layer located at the embankment, cutting, and boundary area of each section. It is observed from this testing that the center deflections of pavement structure with anti-freezing layer are smaller than those without anti-freezing layer. The deflection reduction rates are 15~55% in the embankment, 11~64% in the cutting, and 2~38% in the boundary, respectively. It was also found that the use of antifree zing layer enables to reduce the Surface Curvature Index (SCI) values up to 24 percent. Fatigue lives show that pavement structure with antifreezing layer are about two times higher than the those without anti-freezing layer. This fact indicates that the anti-freezing layer should be considered as a structural layer in the asphalt pavement system.

Establishment of Database for Anti-Frost Heave Layer (동상방지층 설계를 위한 현장 계측자료의 데이터베이스(DB) 구축)

  • Lee, Bum-Woo;Kim, Nak-Seok;Nam, Young-Kug
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.90.1-90.1
    • /
    • 2010
  • 우리나라는 계절적 특성으로 인하여 겨울에서 봄에 이르기까지 도로포장의 동결 융해가 반복되어 도로 파손을 유발 시키고 있다. 동결 융해로 인한 피해를 줄이기 위하여 도로포장 설계시 동상방지층을 별도로 설치를 하고 있으나 실효성 검증 없이 무분별하게 적용되고 있어 국가적으로 예산을 낭비하고 있다. 본 연구에서는 효과적인 동상방지층의 설계를 목적으로 계측된 온도 및 함수비 데이터를 효율적으로 관리하고 모니터링하는 기반을 마련하고자 한다.

  • PDF

The Control of the Ground Frost Heave by Using the Scrap Tire (폐타이어를 이용한 지반동상 방지)

  • 김영진;강병희
    • Geotechnical Engineering
    • /
    • v.14 no.1
    • /
    • pp.49-58
    • /
    • 1998
  • It was investigated whether the scrap tire can be recycled as a construction material for controlling the frost heave of the ground. Some frost heave tests and a frost penetration depth test in the laboratory were performed on the weathered granite soil mitred with variable amount of scrap tire powder under the atmospheric temperature at -$17^{\circ}$ to find the basic effects of the scrap tire on the control of frost. The frost heave control layer of the crushed stone mixed with scrap tire chips directly below thin subbass in the bituminous pavement was found to be effective for practical use. And the equation for the required thickness of this frost heave control layer with freezing index was suggested.

  • PDF

The Freezing Characteristics of Pavement Layer Using the Field Road Model Test (현장도로 모형실험을 이용한 포장구성층의 동결 특성 분석)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.71-80
    • /
    • 2010
  • Korea is considered to be a seasonal frozen soil area that thaws in the spring, and freezes in winter. In the current design codes for anti-freezing layer, the thickness of anti-freezing layer is calculated by the depth frozen due to the temperature condition. Therefore, there is a tendency of over-design and applying uniform thickness without the consideration of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential to study the structural appropriateness of pavement layer and bearing capacity besides the seasonal and mechanical properties of pavement materials to take an appropriate and reasonable design of the road structure. In this paper, the evaluation of frost susceptibility on subgrade, ant-freezing layer, subbase was conducted by means of the mechanical characteristics and model experiment. The temperature, heaving amount, unfrozen water contents and freezing depth of soil samples, the subgrade, anti-freezing layer, subbase soils of road construction site were measured to determine the frost susceptibility.

A Study on Freezing Characteristics of Pavements Using Data of Test Road (시험도로 자료를 이용한 포장의 동결특성 연구)

  • Jeong, Jin-Hoon;Bae, Sung-Ho;Kwon, Soon-Min
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.87-95
    • /
    • 2005
  • To prevent the lowering of structural capability due to freezing and thawing in cold winter, numerous researches on frost heaving have been performed. As the result, the freezing index contour map of the Korea peninsula has been made for the design of the anti-freezing layer of pavements. However, the validity of the anti-freezing layer needs to be evaluated because systematic investigations on the variation of freezing depth with the thickness and material types of pavement layers and the configuration of the ground have been rarely performed. The freezing index of the Korea Highway Corporation test road site was calculated and the freezing depths of the concrete and asphalt pavements of the test road were investigated using the ambient and pavement temperature and water content. In addition, the investigated freezing depths were compared to the values estimated by existing freezing depth models. This is the preliminary study on the freezing-related data measured at the test road. The results with higher reliability will be produced by the long-term accumulation of the data and the analysis on it.

  • PDF

Development of Prediction Model of Frost Penetration Depth on Pavement in Korea (포장도로의 실측값을 활용한 한국형 동결깊이 예측모델 개발)

  • Hong, Seung-Seo;Kim, Young-Seok;Kim, Hak-Seung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.3
    • /
    • pp.47-56
    • /
    • 2010
  • Korea is known to have seasonal frozen ground during a winter season due to climatic and ground conditions. Temperatures below $0^{\circ}C$ cause pavement failure by frost heaving and thaw settlement. A frost protection layer has been constructed in pavements to avoid damage caused by frost action. Anti-frost design methods in Korea have been adopted, which is established in U.S. and Japan. However the characteristics of soils in Korea are different and there are no reasonable modifications to accommodate these characteristics. Therefore, adequate pavement design procedures including seasonal frost action, as well as construction and maintenance practices are required. In this paper, the frost penetration depths along national roads in Korea are presented based on field measurement over several years (1991~2010). The frost penetration depths are analyzed with respect to the Provinces of Korea and sunny/shaded areas.

  • PDF

A Study on The Frost Penetration Depth of Pavement with Field Temperature Data (도로포장 현장계측 온도데이터를 이용한 도로포장체의 동결깊이 연구)

  • Shin, Eun-Chul;Lee, Jae-Sik;Cho, Gyu-Tae
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.21-32
    • /
    • 2011
  • The frost penetration depth of pavement is usually estimated from the freezing index that made temperature data analysis of 30 years and decided the thickness of anti-frost layer. The field monitoring region in study was divided into five regions by freezing index 550~650$^{\circ}C{\cdot}$day, 450~550$^{\circ}C{\cdot}$day and 350~450$^{\circ}C{\cdot}$day. Each region has three-section of road pavement such as cutting area, boundary area of cutting and banking, and lower area of banking. The field monitoring system was established both in the section of anti-frost layer and in the section without anti-frost layer. The data analysis was conducted for determination of frost penetration depth within the paved road by the field monitoring system. The result showed that The temperature of subgrade without anti-frost layer shows below zero in centigrade for the region of freezing index 550~650$^{\circ}C{\cdot}$day, up and down around zero degree in subgrade for the region of freezing index 450~550$^{\circ}C{\cdot}$day, and there is no place existed below zero degree in subgrade for the region of freezing index below 450$^{\circ}C{\cdot}$day. With comparison of field frost penetration depth for the cross-sections of pavement, the cutting area shows the greatest frost penetration depth, and less influence of frost penetration depth for the boundary area of cutting and banking, and the least influenced for the lower area of banking.

Recycling Plan for Waste Concrete Fine Aggregate as Materials of Anti-Frost Layer and Sub-Base Layer (도로의 동상방지층 및 보조기층재로서 폐콘크리트 잔골재의 재활용 방안)

  • Lee, Dong-Wook;Yun, Jung-Mann
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.3
    • /
    • pp.19-25
    • /
    • 2012
  • In this study, a recycling plan for waste concrete fine aggregate as fill material was researched by investigating environmental engineering properties. It is noted that the environmental influence of waste concrete fine aggregate is little since chemical level is satisfied the waste management standard. Waste concrete fine aggregate is not suitable for materials of anti-frost layer and sub-base layer since the particle-size distribution and engineering properties are not partially satisfied the quality standard. However, waste concrete fine aggregate can be recycled as materials of anti-frost layer and sub-base layer if we improve the engineering properties by mixing bigger aggregates than maximum particle size (5 mm) more than 25 percent of total weight.