• Title/Summary/Keyword: 독립적 가변성 기술

Search Result 7, Processing Time 0.022 seconds

A Variability Description Technique for Software Product Line: OVDL (소프트웨어 프로덕트라인 가변성 기술 기법: OVDL)

  • Lee, Ji Hyun;Kang, Sung Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.11
    • /
    • pp.739-746
    • /
    • 2013
  • Variability of the software product line that differentiates member products within a product line must be described with precise meaning and visualized so as easy to select. Moreover, it should be easy to manage. Variability description approaches can largely be divided into two approaches, integrated variability description approach and orthogonal variability description approach. Orthogonal Variability Description Language (OVDL) was developed for clear and precise description of variability without ambiguity. This paper validates the variability description capability of OVDL by translating the variability models of Inter-Working Function (IWF) product line described by using Orthogonal Variability Model (OVM) notations into variability descriptions in OVDL.

Decision Model Specification of Core Assets with Variability and its Tool (가변성을 고려한 핵심 자산의 결정 모델 기술 및 지원도구)

  • 윤석진;이승연;신규상;양영종;박창순
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10b
    • /
    • pp.466-468
    • /
    • 2004
  • 개발한 자산의 재사용성을 증대시키기 위해서는 프로덕트 라인에서 가장 중요한 제품간의 공통성과 가변성을 식별하고 이를 표현하는 기술이 잘 정의되어 있어야 한다 이를 위해서는, 다양한 제품의 요구사항을 만족시켜 줄 수 있도록 자산을 모델링 할 때 가변성을 제공하는 부분을 명세화하고 이를 독립적인 모델로 관리함으로써 자산의 재사용성을 향상시키는 방법이 필요하다. 본 논문은 핵심 자산 개발시 정의하는 결정 모델의 유형을 정의하고 결정요소들 간의 관계를 추적할 수 있는 지원 도구의 프로토타입을 제안한다

  • PDF

Design of variable 4-bar linkage structure for adjustable driving angle (구동 각도 조절이 가능한 가변형 4절링크 설계)

  • Kim, Sang-Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.591-596
    • /
    • 2022
  • Since 4-bar linkage widely used in various industrial fields has a fixed link length, it is inconvenient to add an independent link structure or control device to change the movement of output link. Therefore, this paper proposes a new concept of variable 4-bar linkage mechanism to selectively adjust the movement of the output link to fit desired situations, and applied to the commercial table fans, which is a representative product using a 4-bar linkage system. The optimal rotation angle steps for efficiency are determined experimentally and the appropriate lengths of linkage to fit each step are calculated analytically. Changes in the linkage length are implemented by the rotational motion using a grooved cylindrical cam and the feasibility of the proposed variable linkage mechanism is verified through fabrication and measurement. The presented variable link mechanism is expected to improve the efficiency of industrial robots and fuel valve systems.

A Fairness Based T-MAC Protocol in Wireless Sensor Network (무선 센서 네트워크에서 공평성을 고려한 T-MAC 프로토콜)

  • Nam, Jaehyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.329-331
    • /
    • 2013
  • IEEE 802.11 has become the main technology in wireless network. However, in terms of fairness, arise in its use in ad hoc networks. Two independent emitters nodes can easily monopolize the medium, preventing other nodes to send packets. This paper proposes the modified (m,k)-firm scheme which is based on T-MAC to improve fairness. Also, the proposed scheme uses different TA period according to the number of collision in the node. The simulation result shows that the proposed scheme helps improve the fairness of the DCF.

  • PDF

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Characteristics of Integrated Aging-friendly Technologies into Future Smart Housing (미래주택에 적용될 고령친화기술의 특성연구)

  • Cui, Jing yu;Lee, Yeun sook;Hwang, Ji hye
    • Design Convergence Study
    • /
    • v.15 no.2
    • /
    • pp.1-15
    • /
    • 2016
  • The purpose of this study is to identify the characteristics of aging-friendly technology that can be integrated into future smart homes in an aging society. The literature survey and content analysis method were used to collect and analyze data. Papers of the international journal ICOST (International Conference on Smart Homes and Health Telematics) that professionally deal with converged technologies were analysis units. Sixty-five papers among 215 papers published from 2007 through 2014 were selected on the basis of end-users orientation. Totally, out of 65 papers 76 technology items were extracted. Characteristics of those technologies were analyzed focusing on purpose and application methods. As results, in terms of purpose, the technologies were oriented to provide both of psychological and physiological support to the users, focusing on the safety, convenience, health and entertainment to extend independent life of the elderly. Among the application method such as building structure, furniture, product, wearable device and free movable robot, product were dominant. Through those results, the aging-friendly technology is expected to alleviate a wide range of issues in aging society.

A Comparison of the Independent Verification Methods for the Results of Leksell GammaPlan for Gamma Knife Predecessor with the Hemispherical Collimators (반구형 시준기를 가진 감마나이프에 대한 렉셀감마플랜 결과물의 독립적인 검증방법들의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.521-529
    • /
    • 2016
  • Since Gamma Knife(R) radiosurgery(GKRS) is based on a single-fraction high dose treatment strategy, independent verification for the results of Leksell GammaPlan(R) (LGP) is an important procedure in assuring patient safety and minimizing the risk of treatment errors. Several verification methods have been developed and reported previously. Thus these methods were tested statistically and tried on Leksell Gamma Knife(LGK) target treatments through the embodiment of the previously proposed algorithms(PPA). The purpose of this study was to apply and evaluate the accuracy of verification methods for LGK target treatments using PPA. In the study 10 patients with intracranial lesion treated by GKRS were included. We compared the data from PPA and LGP in terms of maximum dose, arbitrary point dose, and treatment time at the isocenter locations. All data were analyzed by Paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in maximal dose at 10 cases was observed between PPA and LGP. Differences in average maximal dose ranged from -0.53 Gy to 3.71 Gy. The arbitrary point dose calculated by PPA and LGP was not statistically significant too. But we found out the statistical difference with p=0.021 between TMR and LGP for treatment time at the isocenter locations. PPA can be incorporated as part of a routine quality assurance(QA) procedure to minimize the chance of a wrong overdose. Statistical analyses demonstrated that PPA was in excellent agreement with LGP when considering the maximal dose and the arbitrary point dose for the best plan of GKRS. Due to the easy applicability we hope PPA can be widely used.