• Title/Summary/Keyword: 도포재

Search Result 242, Processing Time 0.032 seconds

COMPARISON OF THE ACCURACY OF STONE CASTS MADE FROM ALGINATE IMPRESSION MATERIAL BY MIXING METHODS AND APPLICATION OF TRAY ADHESIVE (알지네이트 인상재의 혼합방법과 트레이 어드헤시브 도포에 따른 모형의 정확도 비교)

  • Kim Jin-Hyung;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.492-501
    • /
    • 2001
  • The use of alginate impression materials today is prevalent because of its efficiency and simplicity in clinical settings. Unfortunately, the simplicity of the procedure tends to lull the dentist into a sense of well-being, and lead him into using careless or sloppy technique. Alginate impression materials are used to fabricate diagnostic and preliminary casts, and the final cast. Incorrect use of this material is known to affect the accuracy of the final prosthesis. The purpose of this study was to compare the effect of different mixing methods of alginate impression material and tray adhesive on the accuracy of the stone cast produced by each method. A total of 30 stone casts were produced by using 3 different types of mixing methods (10 stone cast for each mixing method, respectively). The first method utilized an automatic-mixing machine to mix alginate while the second method was carried out manually, strictly following manufacturer's instructions. The third method also involved manual mixing, but did not follow the manufacturer's instructions and was done in a random fashion. Also, 20 additional stone casts were produced by using alginate with or without tray adhesives were included in the study to evaluate effects of tray adhesives on the accuracy of alginate impression. 10 stone casts were produced by adding tray adhesives to the interior surface of the impression tray prior to taking the impression. The other 10 excluded this step. A total of 50 stone casts were analyzed by the three-dimensional measuring machine to measure and compare the dimensional changes of the impression material of each group. The results are as follows. 1. No significant difference was found between the automatic mixing group and the manually-mixing group(p>0.05). 2. For the group that followed manufacturer's instructions, less dimensional changes were record ed than the group that didn't in measuring distanced 4(p<0.05). 3. The group that used tray adhesives showed less dimensional changes(p<0.05). The findings revealed that mechanical methods of mixing alginate impression materials had little influence on dimensional changes. However, it is proven that following manufacturers instructions in alginate impression taking is an important step in acquiring accurate impressions and tray adhesives may play an important role in enhancing the results.

  • PDF

AN IN VITRO STUDY OF MICROLEAKAGE OF COMPOSITE RESINS (복합레진의 미세누출에 관한 연구)

  • Lee, Sun-Young;Yang, Yeon-Mi;Baik, Byeong-Ju;Jeon, Cheol-Wan;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.593-599
    • /
    • 2003
  • The purposes of this study were to evaluate the microleakage of class V composite resin restorations utilizing the different curing lights, to assess the flowable resin, $Filtek^{TM}Flow$(3M Dental Products, USA) and composite resin, $Filtek^{TM}Z250$(3M Dental Products, USA) which need 20s curing time for halogen light could replace $Z100^{TM}$ Restorative(3M Dental Products, USA) for the microleakage, and to evaluate the effect of adhesive resin on marginal microleakage. Light curing units used in this study were conventional halogen light, XL3000(3M Dental Products, USA) and plasma arc light, Flipo(Lokki, France). Class V cavities were prepared and each cavity was filled with each composite resin. After being filled, the teeth were stored in distilled water, polished, thermocycled and soaked in 1% methylene blue solution. Following results were obtained from evaluation of the sectioned surface. 1. There was no statistically significant difference in microleakage of $Filtek^{TM}Flow$ and $Filk^{TM}Z250$ between two kinds of curing units(p>0.05). 2. Flowable resin, $Filtek^{TM}Flow$ showed more microleakage than Z100 and $Filtek^{TM}Z250$ regardless of curing units(p<0.05). 3. Adhesive resin reduced the microleakage of composite resin in both halogen light and plasma arc light(p<0.05).

  • PDF

IN VITRO EVALUATION OF EXPERIMENTAL FLUORIDE TAPE IN INHIBITION OF ENAMEL DEMINERALIZATION (불소 테이프의 법랑질 탈회 억제 효과에 관한 실험적 평가)

  • Kim, Min-Jung;Lee, Sang-Ho;Lee, Nan-Young;Park, Seung-Hyo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.129-138
    • /
    • 2012
  • The aim of this in vitro study was to evaluate the effectiveness of experimental 2.26% fluoride-polyvinyl alcohol (F-PVA) tape in inhibition of enamel demineralization using enamel surface microhardness (SMH) analysis and scanning electron microscopy (SEM) examination. Enamel specimens (n=60) randomly assigned to four groups: control group, F-PVA tape group, fluoride varinish (F-varnish) group, casein phosphopeptide-amorphous calcium phosphate (CPP-ACFP) group. After topical application, pH-cycling was processed. Then, SMH was measured and the percentage loss of surface microhardness (%SML) was calculated. For the SEM examination, five sample specimens in each group were treated and the morphologic character was evaluated. After pH-cycling, the SMH values of the enamel specimens of F-PVA tape and F-varnish group were significantly higher than that of CPP-ACFP group, there was no significant difference between F-PVA tape and Fvarnish group. With SEM examination, enamel surfaces in the F-PVA tape group and F-varnish group showed numerous spherical and ovoid crystals formed on the enamel surface were also observed. The density of crystals was higher than that of both control group and CPP-ACFP group. F-PVA tape is effective in inhibition of enamel demineralization. Also, F-PVA tape's inhibition of enamel demineralization is comparable to that of F-vanish and greater than that of CPP-ACFP.

LOCAL ANESTHESIA IN CHILDREN USING JET INJECTION INSTRUMENT (분사식 주사기를 이용한 소아환자의 국소마취)

  • Lee, Jae-Chun;Kim, Dae-Eop;Lee, Kwang-Hee;Kim, Seong-Hyeong;Yang, Kye-Sik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.633-637
    • /
    • 2001
  • Local anesthesia procedure in pediatric dentistry using needle-tipped syringes is stressful and painful for the child patients The Syrijet Mark II (Mizzy Inc. USA) is a jet injection instrument, which uses high pressure to propel fluids into soft tissue without the use of a hollow neeldle, so it seems to be able to reduce the injection phobia of the child patients. The authors compared the Syrijet with the conventional syringe by assessing the pain level after local anesthetic procedures using CAS(color analogue scale) which was developed from VAS(visual analogue scale). The result showed that the pain was reduced by the use of syrijet. The advantages of syrijet were no use of neeldes, the reuse of the anesthetic cartridge, and the safety to nerves and vessels. The disadvantages were the large size, the high price, and the need of skill to use.

  • PDF

CHARACTERISTICS OF FLUORIDE RELEASING RESTORATIVE MATERIALS AFTER TOOTHBRUSH-DENTIFRICE ABRASION (잇솔질 마모 처리한 불소방출성 수복재의 특성)

  • Park, Jong-Ha;Baik, Byeong-Ju;Yang, Yeon-Mi;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.705-713
    • /
    • 2004
  • The objectives of this study were to evaluate the fluoride release and the change of surface roughness of fluoride releasing restorative materials after toothbrush-dentifrice abrasion. Seven commercially available fluoride releasing restorative materials (Fuji II LC Improved: FL, Compoglass F: CG, Dyract AP: DR, F2000: FT, Ariston: AT, Tetric: TR, and Gradia: GD) were selected as experimental materials. The results obtained were summarized as follows: 1. The AT, FL, and CF groups produce an initially large burst of fluoride release and comparatively low but continuous release of fluoride. But other groups produce no initial burst of fluoride and levels of release remain relatively constant. 2. The rate of fluoride release remains steady state after 40 days. The results of Tukey's test (P<.05), the fluoride release showed the order of decreasing rank as follows: AT > FL > compomers > TC and GD. 3. The surface roughness indicated that the highest value was observed in the FT group and the lowest value was observed in the CF group. The surface roughness of Tukey's test showed the significant differences between groups of FT, AT and FL and groups of CF, DR, GD and TC (P<0.05).

  • PDF

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN (수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향)

  • Kim, Hak-Geun;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of increasing application time of single bottle adhesives (SBA) to microtensile bond strength (MTBS) of dried dentin. To expose the superficial dentin surfaces, human molars were sectioned perpendicular to the long axis of tooth. $32\%$ phosphoric acid gels were applied for 15s and rinsed. The teeth were randomly assigned to 3 groups ; S group (Single Bond), O group (One-Step), P group (Prime & Bond NT). Each group was divided to 3 subgroups (W: dentin wipe with wet gauge and light cured immediately, D, dentin dried for 30s and light cured immediately, 30: dentin dried for 30s and light cured after applying SBA for 30s). Composite resin was built up on the dentin surface and sectioned to obtain 20 specimens with $1mm^2$ cross sectional area and the MTBS was measured. For Single Bond, the mean MTBS of S-W and S-30 group were higher than that of S-D group statistically (P<0.05). For One-Step, the mean MTBS of O-D group was statistically lower than that of O-W group (P<0.05). For Prime & Bond NT, the mean MTBS of P-30 group was statistically lower than that of P-D group (P<0.05).

Heat Risk Assessment of Wood Coated with Silicone Compounds (실리콘 화합물로 도포된 목재의 열위험성 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.9-19
    • /
    • 2019
  • Experiments on the combustion characteristics of untreated wood specimens and those treated with four types of silicone compounds were carried out using a cone calorimeter according to the ISO 5660-1 standard. 3-Aminopropyltrimethoxysilane (APTMS), 3-(2-aminoethylamino) propylmethyldimethoxysilane (AEAPMDMS), and 3-(2-aminoethylamino) propyltrimethoxysilane (AEAPTMS) were used as the silane compounds. The flame retardants were synthesized with sodium silicate and amino silane compounds. The measured time to ignition after combustion at an external heat flux of $50kW/m^2$ was 9 s to 11 s. Time to ignition was marked with a delayed value in the 3 s to 5 s range. The peak heat release rate ($HRR_{peak}$) was reduced by 5 to 20% compared with the uncoated specimen, and AEAPMDMS showed the highest initial fire risk. The total heat release (THR) was decreased by 1 to 22%. Compared to the untreated specimen, the fire performance index (FPI) of the specimens coated with silicone sol compounds increased by 1.5 to 2.2 fold. The fire growth index (FGI) of the AEAPMDMS specimen was increased by 30% and the others were decreased by 93 to 94%. Therefore, the fire risk of wood coated with silicone compounds was improved in terms of the heat risk properties.

An overview of the regulatory effect of vitamin D supplementation on atopic dermatitis (비타민 D의 기능성: 아토피피부염의 조절에 미치는 영향 연구)

  • Sung, Dong Eun
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.139-148
    • /
    • 2021
  • Atopic dermatitis is a chronic, recurrent, inflammatory skin disease that is a well-known allergic disease with severe itching, making daily life difficult. Since the immunomodulatory action of vitamin D has been reported, several researchers have attempted to determine the correlation between vitamin D and atopic dermatitis. In this review, 41 articles meeting the inclusion criteria were selected and reviewed from the articles published to date. Several studies have reported that low vitamin D levels are associated with the onset of atopic dermatitis and severe atopic dermatitis, but the opinions remain conflicting. Similarly, there are conflicting opinions on the improvement effect of oral vitamin D supplementation on atopic dermatitis, but some possibilities have been suggested. To apply vitamin D as a therapeutic agent for atopic dermatitis, a more systematically designed experiment should be conducted, and an appropriate intake dose for an immunomodulatory function should be obtained.

A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin (화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구)

  • Tai Kwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.138-145
    • /
    • 2023
  • Purpose: In accordance with the increase in the number of buildings repaired and reinforced following deterioration from when a fire occurs in a previously reinforced building, the impact on the structure after the fire is analyzed to establish standards for repair and reinforcement measures. Method: After curing for 28 days, the process was to measure the compressive strength and induce destruction through a compressor, repair and reinforce it with epoxy, and conduct a re-compressive strength test on some specimens after curing for 3 days to understand the degree of strength restoration. The rest of the repaired and reinforced specimens as well as the unrepaired and unreinforced specimens were then put into an oven and heated according to the temporal and temperate conditions listed below, and then the compressive strength was tested to estimate the impact of fire. Result: After reinforcing the yielded specimen with epoxy, the process was to then put it in an oven and heat it at different temperatures over time. It was found that there was a decrease in the strength of the reinforcement more than that of the actual specimen. Conclusion: Based on this, it was found that a building repaired and reinforced with epoxy resin is actually more dangerous than a general unrepaired building when it is damaged by fire, and thus, that it must be prepared for fire vulnerabilities.