• Title/Summary/Keyword: 데이터 지연시간

Search Result 1,233, Processing Time 0.023 seconds

Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy (호흡동조 방사선치료 시 호흡유도시스템의 유용성 평가)

  • Lee, Yeong-Cheol;Kim, Sun-Myung;Do, Gyeong-Min;Park, Geun-Yong;Kim, Gun-Oh;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.167-174
    • /
    • 2012
  • Purpose: The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Materials and Methods: Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and after the therapy. Results: The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. Conclusion: The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory guidance system than free breathing or breathing with auditory guidance alone. In particular, the above system was excellent at the reproduction of respiratory cycles in care units. Such a system enables to reduce time due to unstable breathing and to perform more precise and detailed treatment.

  • PDF

Dietary total sugar intake of Koreans: Based on the Korea National Health and Nutrition Examination Survey (KNHANES), 2008-2011 (한국인의 총 당류 섭취실태 평가: 2008~2011년 국민건강영양조사 자료를 이용하여)

  • Lee, Haeng-Shin;Kwon, Sung-Ok;Yon, Miyong;Kim, Dohee;Lee, Jee-Yeon;Nam, Jiwoon;Park, Seung-Joo;Yeon, Jee-Young;Lee, Soon-Kyu;Lee, Hye-Young;Kwon, Oh-Sang;Kim, Cho-Il
    • Journal of Nutrition and Health
    • /
    • v.47 no.4
    • /
    • pp.268-276
    • /
    • 2014
  • Purpose: The aim of this study is to estimate total sugar intake and identify major food sources of total sugar intake in the diet of the Korean population. Methods: Dietary intake data of 33,745 subjects aged one year and over from the KNHANES 2008-2011 were used in the analysis. Information on dietary intake was obtained by one day 24-hour recall method in KNHANES. A database for total sugar content of foods reported in the KNHANES was established using Release 25 of the U.S. Department of Agriculture National Nutrient Database for Standard Reference, a total sugar database from the Ministry of Food and Drug Safety, and information from nutrition labeling of processed foods. With this database, total sugar intake of each subject was estimated from dietary intake data using SAS. Results: Mean total sugar intake of Koreans was 61.4 g/person/day, corresponding to 12.8% of total daily energy intake. More than half of this amount (35.0 g/day, 7.1% of daily energy intake) was from processed foods. The top five processed food sources of total sugar intake for Koreans were granulated sugar, carbonated beverages, coffee, breads, and fruit and vegetable drinks. Compared to other age groups, total sugar intake of adolescents and young adults was much higher (12 to 18 yrs, 69.6 g/day and 19 to 29 yrs, 68.4 g/day) with higher beverage intake that beverage-driven sugar amounted up to 25% of total sugar intake. Conclusion: This study revealed that more elaborated and customized measures are needed for control of sugar intake of different subpopulation groups, even though current total sugar intake of Koreans was within the range (10-20% of daily energy intake) recommended by Dietary Reference Intakes for Koreans. In addition, development of a more reliable database on total sugar and added sugar content of foods commonly consumed by Koreans is warranted.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.