• Title/Summary/Keyword: 데이터 전송기간

Search Result 148, Processing Time 0.02 seconds

The Design and Implementation of a Real-Time FMD Cattle Burial Sites Monitoring System Based-on Wireless Environmental Sensors (u-EMS : 센서네트워크 기반의 가축매몰지 악취환경정보 실시간 모니터링 시스템 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Gyu;Park, Kyu-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1708-1721
    • /
    • 2011
  • Recent outbreak of cattle diseases such as foot-and-mouth disease(FMD) requires constant monitoring of burial sites of mass cull of cattles. However, current monitoring system takes environmental samples from burial sites with period of between one and two weeks, which makes it impossible for non-stop management of hazardous bio-waste. Therefore, in this study, we suggest an improved real-time environmental monitoring system for such bio-hazardous sites based on wireless sensor networks, which makes constant surveillance of the FMD burial sites possible. The system consists mainly several wireless environmental monitoring sensors(i.e dust, Co2, VOC, NH3, H2S, temperature, humidity) nodes and GPS location tracking nodes. Through analysis of the relayed of the environmental monitoring data via gateway, the system makes it possible for constant monitoring and quick response for emergency situation of the burial sites. In order to test the effectiveness of the system, we have installed a set of sensor to gas outlets of the burial sites, then collected and analyzed measured bio-sensing data. We have conducted simulated emergency test runs and was able to detect and monitor the foul smell constantly. With our study, we confirm that the preventive measures and quick response of bio environmental accident are possible with the help of a real-time environmental monitoring system.

An adaptive resynchronization technique for stream cipher system in HDLC protocol (HDLC 프로토콜에서 운용되는 동기식 스트림 암호 통신에 적합한 적응 난수열 재동기 기법)

  • 윤장홍;황찬식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1916-1932
    • /
    • 1997
  • The synchronous stream cipher which require absoulte clock synchronization has the problem of synchronization loss by cycle slip. Synchronization loss makes the state which sender and receiver can't communicate with each other and it may break the receiving system. To lessen the risk, we usually use a continuous resynchronization method which achieve resynchronization at fixed timesteps by inserting synchronization pattern and session key. While we can get resynchronization effectively by continuous resynchroniation, there are some problems. In this paper, we proposed an adaptive resynchronization algorithm for cipher system using HDLC protocol. It is able to solve the problem of the continuous resynchronization. The proposed adaptive algorithm make resynchronization only in the case that the resynchronization is occurred by analyzing the address field of HDLC. It measures the receiving rate of theaddress field in the decision duration. Because it make resynchronization only when the receiving rate is greateer than the threshold value, it is able to solve the problems of continuous resynchronization method. When the proposed adaptive algorithm is applied to the synchronous stream cipher system in packet netork, it has addvance the result in R_e and D_e.

  • PDF

Design of Low Voltage 1.8V, Wide Range 50∼500MHz Delay Locked Loop for DDR SDRAM (DDR SDRAM을 위한 저전압 1.8V 광대역 50∼500MHz Delay Locked Loop의 설계)

  • Koo, In-Jae;Chung, Kang-Min
    • The KIPS Transactions:PartA
    • /
    • v.10A no.3
    • /
    • pp.247-254
    • /
    • 2003
  • This paper describes a Delay Locked Loop (DLL) with low supply voltage and wide lock range for Synchronous DRAM which employs Double Data Rate (DDR) technique for faster data transmission. To obtain high resolution and fast lock-on time, a new type of phase detector is designed. The new counter and lock indicator structure are suggested based on the Dual-clock dual-data Flip Flop (DCDD FF). The DCDD FF reduces the size of counter and lock indicator by about 70%. The delay line is composed of coarse and fine units. By the use of fast phase detector, the coarse delay line can detect minute phase difference of 0.2 nsec and below. Aided further by the new type of 3-step vernier fine delay line, this DLL circuit achieves unprecedented timing resolution of 25psec. This DLL spans wide locking range from 500MHz to 500MHz and generates high-speed clocks with fast lock-on time of less than 5 clocks. When designed using 0.25 um CMOS technology with 1.8V supply voltage, the circuit consumes 32mA at 500MHz locked condition. This circuit can be also used for other applications as well, such as synchronization of high frequency communication systems.

Thermal Design of Electronic for Controlling X-band Antenna of Compact Advanced Satellite (차세대 중형위성 탑재 X-밴드 안테나 구동용 전자유닛 APD 열설계 및 열해석)

  • Kim, Hye-In;You, Chang-Mok;Kang, Eun-Su;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.1
    • /
    • pp.57-67
    • /
    • 2018
  • The APD (Antenna Pointing Driver) is an electronic equipment tool that is used to drive the two-axis gimbal-type antenna for the image data transmission of CAS (Compact Advanced Satellite). In this study, a heat dissipation of EEE (Electrical, Electronic and Electromechanical) is reviewed, to identify the parts that directly affected its efficiency, lifetime as well as the reliability of the structure. This event eventually incurs a failure of the EEE part itself, or even the entire satellite system as noted in experiments in this case. To guarantee reliability of electronic equipment during the mission, the junction temperature of EEE parts is considered a significant and important design factor, and subsequently must be secured within the allowable range. Therefore, the notation of the thermal analysis considering the derating is indispensable, and a proper thermal mathematical model should be constructed for this case. In this study, the thermal design and thermal analysis are performed to confirm the temperature requirement of the APD. In addition, we noted that the validity of the thermal model, according to each of the identified modeling methods, was therefore compared through the thermal analysis utilized in this case.

Evaluation on the Immunization Module of Non-chart System in Private Clinic for Development of Internet Information System of National Immunization Programme m Korea (국가 예방접종 인터넷정보시스템 개발을 위한 의원정보시스템의 예방접종 모듈 평가연구)

  • Lee, Moo-Sik;Lee, Kun-Sei;Lee, Seok-Gu;Shin, Eui-Chul;Kim, Keon-Yeop;Na, Bak-Ju;Hong, Jee-Young;Kim, Yun-Jeong;Park, Sook-Kyung;Kim, Bo-Kyung;Kwon, Yun-Hyung;Kim, Young-Taek
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.65-75
    • /
    • 2004
  • Objectives: Immunizations have been one of the most effective measures preventing from infectious diseases. It is quite important national infectious disease prevention policy to keep the immunizations rate high and monitor the immunizations rate continuously. To do this, Korean CDC introduced the National Immunization Registry Program(NIRP) which has been implementing since 2000 at the Public Health Centers(PHC). The National Immunization Registry Program will be near completed after sharing, connecting and transfering vaccination data between public and private sector. The aims of this study was to evaluate the immunization module of non-chart system in private clinic with health information system of public health center(made by POSDATA Co., LTD) and immunization registry program(made by BIT Computer Co., LTD). Methods: The analysis and survey were done by specialists in medical, health field, and health information fields from 2001. November to 2002. January. We made the analysis and recommendation about the immunization module of non-chart system in private clinic. Results and Conclusions: To make improvement on immunization module, the system will be revised on various function like receipt and registration, preliminary medical examination, reference and inquiry, registration of vaccine, print-out various sheet, function of transfer vaccination data, issue function of vaccination certification, function of reminder and recall, function of statistical calculation, and management of vaccine stock. There are needs of an accurate assessment of current immunization module on each private non-chart system. And further studies will be necessary to make it an accurate system under changing health policy related national immunization program. We hope that the result of this study may contribute to establish the National Immunization Registry Program.

  • PDF

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

(A Scalable Multipoint-to-Multipoint Routing Protocol in Ad-Hoc Networks) (애드-혹 네트워크에서의 확장성 있는 다중점 대 다중점 라우팅 프로토콜)

  • 강현정;이미정
    • Journal of KIISE:Information Networking
    • /
    • v.30 no.3
    • /
    • pp.329-342
    • /
    • 2003
  • Most of the existing multicast routing protocols for ad-hoc networks do not take into account the efficiency of the protocol for the cases when there are large number of sources in the multicast group, resulting in either large overhead or poor data delivery ratio when the number of sources is large. In this paper, we propose a multicast routing protocol for ad-hoc networks, which particularly considers the scalability of the protocol in terms of the number of sources in the multicast groups. The proposed protocol designates a set of sources as the core sources. Each core source is a root of each tree that reaches all the destinations of the multicast group. The union of these trees constitutes the data delivery mesh, and each of the non-core sources finds the nearest core source in order to delegate its data delivery. For the efficient operation of the proposed protocol, it is important to have an appropriate number of core sources. Having too many of the core sources incurs excessive control and data packet overhead, whereas having too little of them results in a vulnerable and overloaded data delivery mesh. The data delivery mesh is optimally reconfigured through the periodic control message flooding from the core sources, whereas the connectivity of the mesh is maintained by a persistent local mesh recovery mechanism. The simulation results show that the proposed protocol achieves an efficient multicast communication with high data delivery ratio and low communication overhead compared with the other existing multicast routing protocols when there are multiple sources in the multicast group.