• Title/Summary/Keyword: 덕트시스템

Search Result 230, Processing Time 0.026 seconds

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구)

  • Kim, Sung Soo;Sohn, Jang yeul
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.

System Development of Removing Dust and Odor from Manufacturing Process of FRP Products (FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발)

  • Yun, Huy Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • When fiber reinforced plastics (FRP) products are manufactured, dust and odor materials are inevitably generated in a workplace. To improve the bad condition of the workshop, we developed the Hybrid Bag Filter attached activated carbon fiber (ACF) and installed the system at two companies producing FRP goods. In order to raise the efficiency of dust collection, we set the ducts both on the ceiling and at the bottom of the wall and according to the circumstances of the workshop's space, moving dust collector also adopted as a different type of flexible duct. Pulse Jet Type Bag Filter is also equipped to operate the system more effectively, for the improved fine environment because of high dust removal efficiency. Finally, we investigated the removal tendency of the dust and odor when operating the System of Hybrid Bag Filter.

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

A MDA-based Approach to Developing UI Architecture for Mobile Telephony Software (MDA기반 이동 단말 시스템 소프트웨어 개발 기법)

  • Lee Joon-Sang;Chae Heung-Seok
    • The KIPS Transactions:PartD
    • /
    • v.13D no.3 s.106
    • /
    • pp.383-390
    • /
    • 2006
  • Product-line engineering is a dreaming goal in software engineering research. Unfortunately, the current underlying technologies do not seem to be still not much matured enough to make it viable in the industry. Based on our experiences in working on mobile telephony systems over 3 years, now we are in the course of developing an approach to product-line engineering for mobile telephony system software. In this paper, the experiences are shared together with our research motivation and idea. Consequently, we propose an approach to building and maintaining telephony application logics from the perspective of scenes. As a Domain-Specific Language(DSL), Menu Navigation Viewpoint(MNV) DSL is designed to deal with the problem domain of telephony applications. The functional requirements on how a set of telephony application logics are configured can be so various depending on manufacturer, product concept, service carrier, and so on. However, there is a commonality that all of the currently used telephony application logics can be generally described from the point of user's view, with a set of functional features that can be combinatorially synthesized from typical telephony services(i.e. voice/video telephony, CBS/SMS/MMS, address book, data connection, camera/multimedia, web browsing, etc.), and their possible connectivity. MNV DSL description acts as a backbone software architecture based on which the other types of telephony application logics are placed and aligned to work together globally.

Control Law Design for a Tilt-Duct Unmanned Aerial Vehicle using Sigma-Pi Neural Networks (Sigma-Pi 신경망을 이용한 틸트덕트 무인기의 제어기 설계연구)

  • Kang, Youngshin;Park, Bumjin;Cho, Am;Yoo, Changsun
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • A Linear parameterized Sigma-Pi neural network (SPNN) is applied to a tilt-duct unmanned aerial vehicle (UAV) which has a very large longitudinal stability ($C_{L{\alpha}}$). It is uncontrollable by a proportional, integral, derivative (PID) controller due to heavy stability. It is shown that the combined inner loop and outer loop of SPNN controllers could overcome the sluggish longitudinal dynamics using a method of dynamic inversion and pseudo-control to compensate for reference model error. The simulation results of the way point guidance are presented to evaluate the performance of SPNN in comparison to a PID controller.

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례)

  • 김철홍;주영호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

A Study on Active Control of the Radiated Duct Noise with Insufficient Number of Control Dources and Microphones (덕트 내부의 고차모드 수보다 적은 수의 제어음원과 마이크로폰을 이용한 덕트 방사소음 제어에 관한 연구)

  • 윤두병;김양한;정균양;조대승
    • Journal of KSNVE
    • /
    • v.8 no.2
    • /
    • pp.283-288
    • /
    • 1998
  • If one wants to control the noise from a duct, then one must have sufficient number of sensors and actuators so that the control system is observable and controllable. A number of sensors and actuators for control of radiating noise from a duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and actuators than required. In this work, by theoretical analysis and numerical simulation, the control performance and robust reliability of such a kind of control system is investigated in terms of sound-field variables and control system variables. Then the possibility of implementation of the robust radiation power control system is verified by theoretical analysis and numerical simulation. In addition, the control performance of the control system is verified by experiment.

  • PDF

Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex (Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동)

  • Kim, Cheol Hong;Ju, Young Ho;Byun, Hyung Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

Suggestion of Structural Sizing Methodology on a Coaxial Double-tube Type Hot Gas Duct for the VHTR (초고온가스로의 동심축 이중관형 고온가스덕트에 대한 구조정산 방법론 제안)

  • Song, Kee-Nam;Kim, Y.W.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.717-724
    • /
    • 2008
  • Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting the reactor pressure vessel and the intermediate heat exchanger for the VHTR. In this study, structural sizing methodology for the primary HGD with a coaxial double-tube of the VHTR that produces heat at temperatures in the order of $950^{\circ}C$ was suggested and a structural pre-sizing of it was carried out as an example.

  • PDF