• Title/Summary/Keyword: 대형화재

Search Result 421, Processing Time 0.032 seconds

A Study on the Safety Management Standards and Safety Indicators Private Lodging in Farming and Fishing Villages in Rural Area (농어촌민박의 안전관리 기준 및 안전지표에 관한 연구)

  • Suh, hey-sung;Lee, Yong-soo;Kim, Youna-ah
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Various support is provided for the increase in the number of private lodging users in farming and fishing villages and related government policies. However, the bed-and-breakfast accommodation in rural areas lack safety standards or safety indicators for the service pension Gangneung, carbon monoxide leak accident in December 2018, 2020 East Sea in January, Pension. Large gas explosion, accident and is threatening the security of their citizens. Unlike lodging facilities, private lodging in farming and fishing villages is allowed to operate with certain requirements such as fire extinguishers and fire alarms. The purpose of this study is to present safety standards and safety indicators for lodging facilities in farming and fishing villages, which are necessary for the operation management and inspection of local governments and the government related to lodging in farming and fishing villages. Through the study, safety management areas of private lodging in farming and fishing villages were divided into facility safety, fire safety, food safety and living safety, and detailed inspection indicators were presented. There is an academic implication that research on safety management of lodging facilities has been expanded through safety research in areas related to private lodging in farming and fishing villages. It has practical implications in that it provides management standards and indicators that can be used for safety management of private lodging in farming and fishing villages. The limitations of this study are that more studies on private lodging in farming and fishing villages are expected to be conducted through the results of this study, and the lack of research on accommodation safety has prevented more detailed indicators from being derived.

A Study on the Crisis Management Standard Manual for Large-scale Human Accident at Workplace for Efficiency of Disaster Response (재난대응 효율화를 위한 사업장 대규모 인적사고 위기관리 표준매뉴얼 개정방안 연구)

  • Woo Sub Shim;Sang Beam Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.656-664
    • /
    • 2023
  • Purpose: The Ministry of Employment and Labor manages disasters based on the standard manual for risk management of large-scale human accidents in workplaces when large-scale disasters such as fires and collapses occur in workplaces. We are going to check the standard manual currently in operation and suggest improvement plans for the insufficient items. Method: Accordingly, the standard manual was checked together with internal and external experts in the disaster management manual and disaster management staff at headquarters and local government offices, and items to be improved were identified with priority. Result: In case of a collapse accident, it is necessary for the Ministry of Public Administration and Security to accurately present the selection criteria in order to eliminate the controversy over the selection of the disaster management department. In addition, it seems necessary to supplement the details of the disaster safety communication network operation and evacuation guidelines. Conclusion: In the future, in order to improve the disaster management system that meets the public's eye level, it is expected to prepare a standard manual for risk management of large-scale human accidents in workplaces that guarantees the lives and safety of workers through the collection of opinions from experts in the relevant field, disaster management personnel, and the general public.

Fire Retardant Treatment to the Plywood with Di-ammonium Phosphate [(NH4)2 HPO4](I) -Hot and Cold Soaking Treatment and Redrying of Treated Plywood by Hot Platen- (제2인산(第二燐酸) 암모늄에 의한 합판(合板)의 내화처리(耐火處理)(I) -온냉침지처리(温冷浸漬處理)와 열판(熱板)에 의한 처리합판(處理合板)의 재건조(再乾燥) -)

  • Lee, Phil Woo;Chung, Woo Yang
    • Journal of Korean Society of Forest Science
    • /
    • v.60 no.1
    • /
    • pp.30-36
    • /
    • 1983
  • Plywood, the representative interior decorative or structural material, is so inflammable that it may cause big fires. Therefore, it is required inevitably to manufacture the "Fire retardant treated plywood", and it will be a study on the redrying of treated plywood that we ought to solve. This study was carried out to investigate the absorption of 20% $(NH_4)_2HPO_4$ solution into the soaked plywoods by hot/cold soaking for 3/3, 6/3, 9/3 and 12/3 hours and to study drying process with drying curves and drying rates by press-drying at the platen temperature of 130, 145, 160 and $175^{\circ}C$. Solution absorption of plywoods in hot/cold soaking method increased steadily with the prolonged soaking time, and water absorption is higher than DAP absorption, and then chemical retention (DAP) exceeded the minimum retention [$1.125kg/(30cm)^3$] even in the shortest soaking treatment. Drying curves of water-soaked plywoods inclined more steeply than those of DAP soaked plywoods. And the drying proceeded rapidly with the increase in platen temperature and terminated in 2.5-4 minutes at the temperature of 160 and $170^{\circ}C$. Drying rate also increased generally with the increase of platen temperature. So it was at $175^{\circ}C$ in DAP-soaking and at $160^{\circ}C$ in water-soaking when the drying rate became above 10%/min.

  • PDF

The Research on the Life-safety Implementation using the Natural Light LED Lamp in the Disaster Prevention and Safety Management (방재안전 자연광 LED 조명을 이용한 생활안전 개선에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;So, Yooseb;Choi, Byungshik;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • This paper is shown the new method using LED Light, which the light environment is upgraded the natural LED light in the area of Disaster Prevention and Safety Management (PDSD), which the events of deaths is reduced on the Suicide, the Infectious diseases, the safety accidents, the Traffic Accident, the crime, the fire, the Nature Disaster, and which the health and the environment and the safety is implemented using the value of the color LED Light. Research findings include,during 3 weeks in the November 2016, in the ten residents (average living 28.7 years, age 67.5 years) with depressive symptoms in the northern part of Seoul, according to the request of the user, the PDSD natural light LED lighting was installed in the home bedroom or the living room, expectations for the ability to restore physical and mental stability were high (88%), in the same way, after 1 week and 3 weeks, the physical and mental changes were compared and the results,84% in the first week and 90% in the third week and thereafter, the effect of relieving depression was high. We conclude that patients with depression have a good sleep, an uneasy feeling, a sense of security, a good night's sleep, and a good feeling. The PDSD LED Light is expected to contribute in the various areas, which reduced the suicides, which give increased immunity from infectious diseases, which give a crash to reduce accidents caused by negligence, which improve the safe operation of heavy vehicles in which a traffics accident incidence installed on the highest point, which improve the safety function on the 'safety way home' for the safety of the community, which due to fire gives alleviate the emotional anxiety of firefighters, which improve the environment for long-term control room working during decision making caused by natural disasters.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Factors Affecting South Korean Disaster Officials' Readiness to Facilitate Public Participation in Disaster Management Using Smart Technologies (재난안전 실무자의 스마트 재난관리 준비도에 영향을 미치는 요인에 관한 실증 연구 - 스마트 기술을 활용한 재난관리 민간참여 중심으로 -)

  • Lyu, Hyeon-Suk;Kim, Hak-Kyong
    • Korean Security Journal
    • /
    • no.62
    • /
    • pp.35-63
    • /
    • 2020
  • As the frequency and intensity of catastrophic disasters increase, there is widespread public sentiment that government capacity for disaster response and recovery is fundamentally limited, and that the involvement of civil society and the private sector is ever more vital. That is, in order to strengthen national disaster response capacity, governments need to build disaster systems that are more participatory and function through the channels of civil society, rather than continuing themselves to bear sole responsibility for these "wicked problems." With the advancement of smart mobile technology and social media, government and society as a whole have been called upon to apply these new information and communication technologies to address the current shortcomings of government-led disaster management. As illustrated in such catastrophic disasters as the 2011 Tohoku earthquake and tsunami in Japan, the 2010 Haitian earthquake, and Hurricane Katrina in the United States in 2005, the realization of participatory potential of smart technologies for better disaster response has enabled citizen participation via new smart technologies during disasters and resulted in positive impact on the management of such disasters. In this context, this study focuses on the South Korean context, and aims to analyze Korean government officials' readiness for public participation using smart technologies. On this basis, it aims to offer policy suggestions aimed at promoting smart technology-enabled citizen participation. For this purpose, it proposes a particular model, termed SMART (System, Motivation, Ability, Response, and Technology).

Spatial Patterns and Temporal Variability of the Haines Index related to the Wildland Fire Growth Potential over the Korean Peninsula (한반도 산불 확장 잠재도와 관련된 Haines Index의 시.공간적 특징)

  • Choi Cwang-Yong;Kim Jun-Su;Won Myoung-Soo
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.2 s.113
    • /
    • pp.168-187
    • /
    • 2006
  • Windy meteorological conditions and dried fire fuels due to higher atmospheric instability and dryness in the lower troposphere can exacerbate fire controls and result in more losses of forest resources and residential properties due to enhanced large wildland fires. Long-term (1979-2005) climatology of the Haines Index reconstructed in this study reveals that spatial patterns and intra-annual variability of the atmospheric instability and dryness in the lower troposphere affect the frequency of wildland fire incidences over the Korean Peninsula. Exponential regression models verify that daily high Haines Index and its monthly frequency has statistically significant correlations with the frequency of the wildland fire occurrences during the fire season (December-April) in South Korea. According to the climatic maps of the Haines Index created by the Geographic Information System (GIS) using the Digital Elevation Model (DEM), the lowlands below 500m from the mean sea level in the northwestern regions of the Korean Peninsula demonstrates the high frequency of the Haines Index equal to or greater than five in April and May. The annual frequency of the high Haines Index represents an increasing trend across the Korean Peninsula since the mid-1990s, particularly in Gyeongsangbuk-do and along the eastern coastal areas. The composite of synoptic weather maps at 500hPa for extreme events, in which the high Haines Index lasted for several days consecutively, illustrates that the cold low pressure system developed around the Sea of Okhotsk in the extreme event period enhances the pressure gradient and westerly wind speed over the Korean Peninsula. These results demonstrate the need for further consideration of the spatial-temporal characteristics of vertical atmospheric components, such as atmospheric instability and dryness, in the current Korean fire prediction system.

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.

The Effect of the Performance of Firefighting Construction Supervision Personnel on the Completion Inspection of Firefighting Facility Construction in Apartments (소방공사감리원의 업무수행능력이 아파트 소방시설공사의 완공검사에 미치는 영향)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.43-54
    • /
    • 2019
  • In this study, results of completion inspection are investigated according to the performance of the firefighting construction supervision personnel and according to the necessity of clean air supply in a performance test of the firefighting construction supervision personnel. The results of the completion inspection are measured and the causes of defects in the fire protection facilities after issuance of a completion inspection certificate are analyzed. The findings of this investigation can be used to minimize the risk of apartment fires and improve the performance of firefighting construction supervision personnel. The results of this study are summarized as follows. First, the results of the completion inspection conducted by the firefighting construction supervision personnel varies according to particular occupation. The performance of fire facility supervisors from design companies and fire construction companies were significantly higher than the fire officers. Therefore, it is necessary to employ supervisors who have experience in supervising the construction of apartments, in order to improve the performance of fire construction supervision officers. Second, the analysis of the completion inspection results according to the necessity of a clean air supply for performance tests of firefighting construction supervision personnel showed that the necessity of a clean air supply was significantly higher for fire facility supervisors from design companies and fire construction companies than for the fire officers. In order to improve, the completion inspection should be carried out up until the completion date of the building. In addition, a system needs to be established to ensure that clients are not able to demand that a completion inspection certificate be issued on the construction completion date. Finally, it is found that defects of completion inspection after issuance of a completion inspection certificate affects the result of the completion inspection. The results of the completion inspections conducted by the fire facility supervisors from design companies and fire construction companies were affected significantly less by defects than that of the general contractors. Research shows that faults have occured in firefighting facilities after the issuance of a completion inspection certificate due to the client and the construction company demanding the issuance of the completion inspection certificate.

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF