• Title/Summary/Keyword: 대퇴터널

Search Result 48, Processing Time 0.022 seconds

Two-Bundle Anterior Cruciate Ligament Reconstruction with Single Femoral Tunnel and Tibialis Anterior Tendon Allograft (단일 대퇴 터널과 전경골 동종건을 이용한 이중 다발 전방십자인대 재건술)

  • Kim, Yeung-Jin;Chae, Soo-Uk;Yang, Jung-Hwan;Lee, Ji-Wan;Shim, Sung-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.107-113
    • /
    • 2010
  • Purpose: To evaluate the outcome of the two-bundle anterior cruciate ligament reconstruction with single femoral tunnel and tibialis anterior tendon allograft and to determine any functional advantages. Materials and Methods: From June 2006 to March 2008, we performed single femoral tunnel and two-bundle ACL reconstruction with tibialis anterior tendon allograft in 26 cases. Mean age was 35.5 years. 20 cases were male and 6 cases were female. Average follow-up period was 2 years and 5 months, range from 1 year to 3 years and 5 months. Subjective and objective parameters were utilized in analyses, such as the mean range of motion, Lysholm knee score, Tegner activity score, Lachman test and IKDC score. Results: Postoperative mean Lysholm knee score, IKDC Evaluation Form, Tegner activity scale, Pivot shift test, and anterior displacement by the Telos stress test demonstrated statistically significant differences compared to the preoperative. Conclusion: Two-bundle anterior cruciate ligament reconstruction with single femoral tunnel showed good clinical results and was good operative technique.

  • PDF

7 to 22Y Follow-up of Anterior Cruciate Ligament Reconstruction : from the standpoint of OA (전방 십자 인대 재건술 7년에서 22년 장기 추시: 관절염 관점에서)

  • Yang, Sang-Hoon;Sim, Jae-Ang;Kwak, Ji-Hoon;Kim, Byung-Kag;Ahn, Byung-Moon;Lee, Beom-Koo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.20-24
    • /
    • 2010
  • Purpose: To evaluate the long term outcomes of the ACL reconstruction from the standpoint of osteoarthritis. Materials and Methods: We evaluated 31 patients who underwent ACL reconstruction from April 1986 to April 1999 and could be followed-up more than 7 years. Mean follow-up period was 10.1 years (7~22 years). In terms of the graft, 11 cases were treated with the ACL reconstruction using a autologous hamstring tendon graft, 20 cases were treated with using a autologous bone patellar tendon bone graft. For femoral tunnel, 11 cases were placed through transtibial tunnel, 20 cases were placed through anteromedial portal using mini-open arthrotomy. Functional and radiographic evaluation was performed. Results: Mean Lysholm score was $89.2{\pm}11.7$ points. Patients had KT-2000 side-to-side differences were $2.1{\pm}1.9\;mm$. IKDC ligament evaluation showed 38.7% type A, 48.3% type B, 6.5% type C and 6.5% type D. Femoral tunnel were placed at 11 or 1 o'clock position in transtibial technique and placed 10 to 10:30 or 2 to 2:30 o'clock position in technique using anteromedial portal. Radiographic analysis for degenerative arthritis revealed that in group using anteromedial tunnel, 50.0% were excellent, 25.0% were good. In group using transtibial tunnel 18.2% were excellent, 18.2% were good. Conclusion: More than 87.1% of cases, long term result of the ACL reconstruction showed good and excellent result in IKDC score. Especially, the group using tunnel through anteromedial portal showed good results for degenerative arthritis.

  • PDF

Arthroscopic Repair of Acute Posterior Cruciate Ligament Rupture with Autogenous Hamstring Tendon Graft Augmentation - Technical Note (급성 후방 십자 인대 파열의 관절경하 봉합술 및 자가 슬괵 이식건 보강술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Sung, Kee-Lyong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.70-76
    • /
    • 2005
  • Purpose: We describe a new technique of arthroscopic repair with using autogenous hamstring tendon graft augmentation for the acute posterior cruciate ligament rupture. Operative technique: A routine arthroscopic examination of the knee joint is initially performed, then the posterior trans-septal portal is prepared with the using the posteromedial and posterolateral portals. The torn tibial stump that is retracted to the posterior compartment is repaired by a suture hook that is introduced through the anteromedial portal; visualization during this procedure is done with the arthroscope via the posteromedial portal. Using the retrieved suture, both suture ends are brought out to the anteromedial portal. The torn tibial stump is pulled to the intercondylar notch and then repaired with stitches at the anterior compartment. After the tibial and femoral tunnels are prepared without damaging the remnant PCL bundle, the combined torn PCL fibers and the autogenous single-bundle semitendinosus and gracilis tendon grafts are passed through the femoral tunnel and fixed together Conclusion: Arthroscopic repair of the torn tibial stump and autogenous hamstring tendon graft augmentation after preparing the tibial and femoral tunnels by using the trans-septal portal, without damaging the remnant PCL bundle, seems to be a very effective method for the treatment for acute PCL injuries, and especially for tears at the femoral attachment.

  • PDF

Second-look Arthroscopic Findings after ACL Reconstruction - The Changes around Graft - (전방 십자 인대 재건술후 2차 관절경 검사 소견 - 이식건 주위의 변화 -)

  • Hahn Sung-Ho;Yang Bo-Kyu;Yi Seung-Rim;Chung Shun-Wook;Hwang Hoon;Ko Dong-Oh;Kwon Gi-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.13-16
    • /
    • 2001
  • Purpose : To evaluate the types of the fibrous scar formation around graft after ACL reconstruction. Materials and Methods : Between Nov 1997 and Jun. 1999, the second look arthroscopy was performed on 15 knees of 14 patients. We evaluated the changes around graft and measured the tunnel position that the tibial tunnel position as a percentage along the length of the tibial plateau from the anterior-to-posterior as seen on a lateral radiograph and the femoral tunnel position as a percentage along Blumensaat's line from anterior-to-posterior as seen on a lateral radiograph. Results : The tibial tunnel position was from $27\%\;to\;58\%(mean\;41\%)$ and the femoral tunnel position was from $58\%\;to\;83\%(mean\;76\%)$, so the tunnel position was ideal in almost cases. By arthroscopic findings, the grafts were not impinged in all cases and tile fibrous scar was formed between intercondylar notch and graft in almost cases except 3 cases. The types of fibrous scar formation were 6 cases of fibrillated fiber and 5 cases of fibrous nodule and 1 case of fibrous band. Conclusion : There was no impingement on graft in all cases and various types of fibrous scars were formed around grafts.

  • PDF

Single Bundle PCL Reconstruction with Remnant Preservation (잔여 조직을 보존한 단일 다발 후방십자인대 보강재건술)

  • Lee, Dong Chul;Kim, Won-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • Optimal treatment of the torn posterior cruciate ligament (PCL) remains controversial. The type of tibial fixation (transtibial vs inlay), the femoral tunnel position within the femoral footprint (central, eccentric or isometric), and the number of bundles in the reconstruction (single-bundle vs double-bundle) are controversial issues. The PCL has a better chance of spontaneously healing than the anterior cruciate ligament (ACL) because of a rich blood supply (near the branch of the middle genicular artery) and coverage with a thicker synovium. In general, for easier passage of the graft and full visualization of the original ligament attachment site during the precise positioning of the tunnel, the remaining PCL fibers are usually debrided during reconstruction. However, the remaining remnant structures would significantly contribute to the posterior stability of the knee joint, the healing of the graft, preserving proprioceptive function of the mechanoreceptors in the PCL. Double bundle PCL reconstruction may result in some surgical complications because of increased complexity of making tunnel. Therefore, single bundle PCL reconstruction with remnant preservation seems to be an effective procedure.

  • PDF

Transtibial Double Bundle PCL Reconstruction using TransFix Tibial Fixation - Technical Note - (TransFix 경골부 고정을 이용한 경 경골 두 다발 후방십자인대 재건술 - 수술 술기 -)

  • Lee, Yong-Seuk;Jung, Young-Bok;Ahn, Jin-Hwan;Kang, Bun-Jung;Shin, Yun-Chang;Kong, Chae-Gwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • Purpose: Previous transtibial double bundle posterior cruciate ligament (PCL) reconstruction methods have several problems in graft length and tibial fixation. We introduce new surgical method that is less restrictive by graft length and is more stable with single tibial fixation. Operative technique: After diagnostic arthroscopy, we prepare the graft, ream the tibial tunnel and perform the procedure for TransFix tibial fixation. Femoral 2 tunnel is made and graft is passed via anteromedial (AM) portal. Tibial fixation is done and femoral 2 graft is fixed sequentially at each knee position. Conclusion: TtransFix tibial single fixation method in double bundle PCL reconstruction provides more stable fixation, more free graft selection and prevents graft damage by passing the graft via AM portal.

  • PDF

The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$ (Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과)

  • Kim, Doo-Sub;Rah, Jung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • Purpose: We used tibialis allograft for the reconstruction of ACL and used Hybrid femoral fixation utilizing $Endobutton^{(R)}$ and $Rigidfix^{(R)}$ for femoral fixation, and used $Retroscrew^{(R)}$ and additional fixation for tibial fixation to evaluate the clinical results. Materials and Methods: The ACL reconstruction were performed from February 2004 to February 2007 utilizing Hybrid femoral fixation and $Retroscrew^{(R)}$ and 32 patients, 32 cases which were available for year-long observation (12 to 25 months). The clinical results (Lysholm knee score, IKDC grade) and the radiologic results(bone tunnel expansion, Telos anterior displacement test) were evaluated. Results: The Lysholm knee score was improved from the average of $67.9{\pm}5.4$ points (range: 51~77) before operation and to $94.1{\pm}6.8$ points (range: 68~98) at the last follow up (p<0.05). 22 cases (69%) were evaluated normal (A), 9 cases (28%) were evaluated nearly normal (B) and only 1 case (3%) was evaluated not normal (C) at IKDC final evaluation and no case was evaluated abnormal. From $Telos^{(R)}$ stress x-ray evaluation, difference from the opposite knee was improved average 13.2 mm{\pm}5.8 (range: 6~21 mm) to average $3.4\;mm{\pm}2.8$ (range: 0~11 mm) after operation (p<0.05). The femoral and tibial tunnel were widened by 18.7% and 9.6% in the AP view and 12.4% and 8.5% in the lateral view, respectively (p<0.05). However, any statistic significance was not observed between bone tunnel expansion and knee joint functions (p>0.05). Conclusion: An ACL reconstruction with tibialis allograft using Hybrid femoral fixation and $Retroscrew^{(R)}$ enabled anatomical fixation of the graft tendon with satisfactory clinical results.

  • PDF

Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Park, Han-Chang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.

  • PDF

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF