• Title/Summary/Keyword: 대퇴골 골절

Search Result 115, Processing Time 0.021 seconds

Additive Manufacturing of Patient-specific Femur Via 3D Printer Using Computed Tomography Images (CT 영상을 이용한 3D 프린팅으로 환자 맞춤형 대퇴골 첨삭가공)

  • Oh, Wang Kyun;Lim, Ki Seon;Lee, Tea Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.359-364
    • /
    • 2013
  • Femur is the largest bone in the human body which supports the weight of body. A long pipeline shape of femur has little cancellous bone, so that regeneration is difficult when fracture happens. The fracture caused by an accident most frequently occurs at diaphysis. IM Nailing is the surgical method that implants an IM Nail into a medullary cavity for the fixation of fracture parts. However, a secondary fracture may happen if an IM Nail does not penetrate at the center of femur. In this study, a patient-specific femur was manufactured by a 3D printer using the computed tomography images scanned before surgery, which was used for the simulation of IM Nailing. It is expected that this result may prevent the secondary damage, reduce surgical operation time, and increase the precision.

Analysis on Femoral Neck Fractures Using Morphological Variations (파라메트릭 형상모델을 이용한 근위 대퇴골의 경부 골절 영향 해석)

  • Lee, Ho-Sang;Park, Byoung-Keon;Chae, Je-Wook;Kim, Jay-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.459-465
    • /
    • 2011
  • It has been reported that the femoral morphology has a major correlation to femoral neck fractures(FNF). Previous studies to analyze these correlations have relied on mechanical testing and finite element methods. However, these methods have not been widely applied to various femur samples and models. It is because of the availability of the samples from both patients and cadavers, and also of the geometric limitations in changing the shape of the models. In this study we analyzed femoral neck fractures using a parameterized femoral model that could provide flexibility in changing the geometry of the model for the wide applications of FNF analysis. With the parameterization a variety of models could be generated by changing four major dimensions: femoral head diameter(FHD), femoral neck diameter(FND), femoral neck length(FNL), and neck-shaft angle(NSA). We have performed FEA on the models to compute the stress distributions and reaction forces, and compare them with the data previously generated from mechanical testing. The analysis results indicate that the FND is significantly related with the FNF and the FHD is not significantly related with the FNF.

Femur Fractures Associated with Benign Bone Tumors in Children (양성 골종양을 동반한 소아 대퇴골의 병적 골절)

  • Jung, Sung-Taek;Kim, Byung-Soo;Moon, Eun-Sun;Lee, Keun-Bae;Seo, Hyoung-Yeon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2005
  • Purpose: We evaluate the results of treatment of pathologic femur fractures secondary to bone tumors in children. Materials and Methods: Between January 1995 and June 2004, 18 patients(20 cases) were evaluated. Their mean age of the first episode of fracture was 10.2 years and mean follow-up period is 42.5 months. Primary bone tumors, the location of fracture, time to union and complications were evauated. Results: Fractures occurred at proximal portion in 14 cases, shaft 3 cases and distal portion 3 cases. The bone tumors causing pathologic fracture were fibrous dysplasia(9 c ases), simple bone cyst(4 cases), aneurysmal bone cyst(4 cases), nonossifying fibroma(2 cases) and eosinophilic granuloma(1 case). In the treatment for fractures, cast was in 11 cases, internal fixation 8 cases and external fixation in 1 case. In the treatment for tumors, observation was in 11 cases, curettage & bone graft in 8 cases and resection in 1 case. In polyostotic fibrous dysplasia, all cases were treated by cast initially but deformity developed in all cases. Fracture prevention and deformity correction were obtained with intramedullary nailing. Conclusion: Adequate choice of treatment of bone tumor and fracture will result in good prognosis.

  • PDF

An Atypical Subtrochanteric Femoral Fracture in a Patient with Multiple Myeloma Received Zoledronic Acid: A Case Report (졸레드론산을 투여한 다발성 골수종 환자에서 발생한 비전형적 대퇴골 전자하 골절: 증례 보고)

  • Jeong, Won-Ju;Na, Sang-Bong;Cho, Hwan-Seong;Kim, Joon-Woo;Park, Il-Hyung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.99-103
    • /
    • 2012
  • Little literature exists about the risk of atypical femoral fracture in patients received zoledronic acid for prevention of skeletal metastasis. We report an atypical subtrochanteric femoral fracture in a patient with multiple myeloma received zoledronic acid. The patient was treated by closed reduction and internal fixation with cephalomedullary nailing.

Effects of Chitosan on Fracture Healing in Fractured Rat Model. (골절모델 쥐에서 키토산 투여가 골절치유에 미치는 영향)

  • 서정욱;김은주;한상섭
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.385-390
    • /
    • 2004
  • Chitosan is abundant polysaccharide polymer in nature Chitosan has been the subject of much research regarding its potential as a nutritional adjunct and pharmaceutical ingredient. In the present study, we examined fracture-healing process with chitosan administration and low calcium diet in rats. Left femur was fractured and fixed with intramedullary pin. The rats were fed normal diet or low calcium diet and administered chitosan with the doses of 0, 50, 100 and 150ng/ml orally 5 times a week for 10 weeks. Soft X-ray and mechanical testing of all fractured femora was taken. Radiographical finding showed that the callus formation and process of fracture healing was present in all the fractured femora. Mechanical testing indicated that the maximum load and stiffness of femur in rat fed low calcium diet was lower than those of that in rat fed normal diet. No difference in maximum load and stiffness of fractured femora in chitosan treated rat were observed as compared to vehicle treated rat. Chitosan or/and low calcium diet did not affect the ratio of fractured/unfractured femur about maximum load and stiffness. The results suggest that chitosan dose not affect the bone mechanical strength and the process of fracture healing. Low calcium diet does decrease the bone mechanical strength.

Pseudoaneurysm Originating from the Lateral Femoral Circumflex Artery after Retrograde Intramedullary Nailing of a Distal Femur Shaft Fracture (원위 대퇴골 골절에서 역행성 골수 정 시행 후 발생한 외측 대퇴 회선 동맥 기원의 가성동맥류)

  • Yu, Jeongseok;Lee, Beom-Seok;Kim, Han-Bit
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.535-539
    • /
    • 2021
  • Vascular complications following a femoral fracture are rare but can result in serious issues. Several case studies have reported pseudoaneurysms occurring after direct trauma or the insertion of a proximal femoral nail in the case of a proximal femoral fracture. The authors encountered an 85-year-old patient treated with retrograde intramedullary nail fixation for a distal femur fracture and suffered a decrease in the hemoglobin level, swelling, and pain on the 9th day after surgery. The authors initially attributed the temporary hematoma and pain to ordinary postoperative processes. On the 16th day after surgery, a pseudoaneurysm originating from the descending branch of the lateral femoral convolutional artery was diagnosed and treated by percutaneous vascular embolization. After the procedure, the hemoglobin level increased, and the swelling and pain decreased.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Femoral Bony Avulsion Fracture of the Posterior Cruciate Ligament in a Seventy one Year Old Man - A Case Report - (71세 남자에서 발생한 후방십자인대 대퇴골 부착부 견열 골절 - 1례 보고 -)

  • Lee, Yeong-Hyeon;Ahn, Gil-Yeong;Nam, Il-Hyun;Moon, Gi-Hyuk;Kim, Ki-Choul;Lee, Chae-Kyung;Lee, Sang-Chung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.128-130
    • /
    • 2010
  • Femoral avulsion fracture of posterior cruciate ligament (PCL) is rare, especially in adult. We experienced a case of femoral bony avulsion fracture of PCL. The patient was seventy one year old man with limitation of motion in the knee joint due to previous trauma and he was injured by fall down from 2 m height. We took CT scan and MRI study. We treated with arthroscopic repair technique using transfemoral two wire sutures. Second look arthroscopy was done for removal of the wires at postoperative one year.

  • PDF

New Approach in the Treatment of Intertrochanteric Fracture Using a Cephalomedullary Nail (골수정을 이용한 대퇴골 전자간 골절의 새로운 치료 경향)

  • Kim, Junyoung;Choi, Kihong;Yang, Kyu Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • A gamma nail has been used to treat intertrochanteric fractures since 1988. Although such cephalomedullary nails have mechanical advantages over extramedullary fixation devices, such as sliding hip screw, their beneficial effects on treating the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31-A1 and 31-A2 fractures are still controversial. During their 30-year history, many problems have been overcome, and new types of cephalomedullary nails have been introduced in clinical practice. New cephalomedullary nail systems facilitate nailing procedures and enhance the purchase capability of the femoral head by a lag screw. On the other hand, the failure rate still depends on the hands of the orthopedic surgeons. This review article focused on the basic principle of medial support and restoration of a medial buttress during the treatment of trochanteric fractures using a cephalomedullary nail.

Influence of Impact Angle on Deformation in Proximal Femur during Slide Falling (측방 낙상시의 충격 각도가 대퇴골 근위부의 변형에 미치는 영향)

  • 김병수;배태수;김정규;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.233-239
    • /
    • 2003
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly, hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. Nevertheless, hip fracture accounts for a considerable part of the disability, death, and medical costs associated with falling. In this study, we considered the impact angle and displacement rate in falling as another factor affecting femoral strength. Using a fresh-frozen human femur, we developed system to simulate the falling condition and then conducted the experiments changing the impact angle (0$^{\circ}$, 15$^{\circ}$, 30$^{\circ}$) of proximal femur. Also, in order to analyze the relative risk due to falling to normal situation in proximal femur, we did the static test simulating the two-legged stance condition. The results showed that the change in impact angle affected the strain distribution in proximal femur, and that a large deformation in femoral neck than in other sites. Furthermore despite low impact velocity, a large deformation in proximal femur occurred in the impact test and different strain distribution was observed compare to the static case.