• Title/Summary/Keyword: 대동맥 판막

Search Result 322, Processing Time 0.028 seconds

A Numerical Analysis on the Motion of Mechanical Heart Valve(MHV) and Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 기계식 인공심장판막(MHV)의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang Jin-Seok;Choi Choeng-Ryul;Kim Chang-Nyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.154-161
    • /
    • 2005
  • In this study, the leaflet motion of a mechanical heart valve and the characteristics of two-dimensional transient blood flow in an elastic blood vessel have been numerically investigated by using fluid-structure interaction method. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. As a result, closing motion of the leaflet is faster than opening one. While opening angles of leaflet grow up, vortex is detected at the sinus and backward of the leaflets. When the leaflet is fully closed, vortex is detected at the ventricle and at that moment maximum displacement of the elastic blood vessel is observed in the vicinity of the sinus region. Maximum displacement is caused in association with the blood flow that is oriented toward the elastic blood vessel.

Research of PPI prediction model based on POST-TAVR ECG (POST-TAVR ECG 기반의 PPI 예측 모델 연구)

  • InSeo Song;SeMo Yang;KangYoon Lee
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.29-38
    • /
    • 2024
  • After Transcatheter Aortic Valve Replacement (TAVR), comprehensive management of complications, including the need for Permanent Pacemaker Implantation (PPI), is crucial, increasing the demand for accurate prediction models. Departing from traditional image-based methods, this study developed an optimal PPI prediction model based on ECG data using the XGBoost algorithm. Focusing on ECG signals like DeltaPR and DeltaQRS as key indicators, the model effectively identifies the correlation between conduction disorders and PPI needs, achieving superior performance with an AUC of 0.91. Validated using data from two hospitals, it demonstrated a high similarity rate of 95.28% in predicting PPI from ECG characteristics. This confirms the model's effective applicability across diverse hospital data, establishing a significant advancement in the development of reliable and practical PPI prediction models with reduced dependence on human intervention and costly medical imaging.

Clinical Results of the St. Jude Medical Cardiac Valve (St. Jude 기계판막의 임상성적)

  • 장기경;윤후식
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.959-963
    • /
    • 1996
  • St. Jude Medical bileaflet valve was implanted in 42 patients from September, 1988, to July, 199)(mitral valve replacement in 25, aortic valve replacement in 11, multiple valve replacement in 6). Concomitant procedures were performed in 5 patients(11.9%). The early mortality was 4.8%(2 patients) and the late mortality was 9.5%(4 patients). The valve-related causes of late mortality were prosthetic valve endocarditis(threi), unknown(one). There was no instance of structural failure. Follow up was 100% complete, with 179.8 patient-years and a mean follow up of 54 months(from 1.5 to 84 months). The overall actuarial survival rates was 90$\pm$4.7% at 5 years. At 5 years, the acturarial freedom from valve failure was 90$\pm$4.7%, 89.7$\pm$4.5% from thromboembolism and 92.3 $\pm$4.2% from bacterial endocarditis, respectively.

  • PDF

Animal Experiment and Blood Biocompatibility Study of Polymer Valve (고분자판막의 동물실험 및 생체내 혈액적합성 연구)

  • 김상현;홍유선
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.357-362
    • /
    • 1997
  • In vivo testings of the monoleaflet polymer valve were performed in seven dogs to prove its blood biocompatibility. The monoleaflet polymer valve used in this study was developed for short-term usage n the ventricular assist device. The frame and leaflet of the polymer valve were made of polyurethane. The inter-aortic valved conduit were implanted in four dogs and the ventriculo-atrial valved conduit was implanted in one dog. The ventricular assist devices with polymer valve were implanted in two dogs. The longest survival was 20 days. Main causes of death were bleeding and infection. To examine the blood compatibility, each blood sample was collected and RBC, WBC, hematocrit, hemoglobin, platelet and lactic acid dehydrogenase were analyzed. These studies thus far demonstrated that, with further development, a reliable and inexpensive polymer valve will be used in the ventricular assist device as short term usage.

  • PDF

Mitral Valve Reconstruction in Mitral Insufficiency : Intermediate-Term Results (승모판 폐쇄부전증에서 승모판 재건술의 중기평가)

  • 김석기;김경화;김공수;조중구;신동근
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.705-711
    • /
    • 2002
  • The advantages of mitral valve reconstruction have been well established and so mitral valve reconstruction is now considered as the procedure of choice to correct mitral valve disease. This is the report of intermediate-term results of 38 cases that performed mitral valve reconstruction for valve insufficiency(the total number of mitral valve reconstruction were 49 cases, but 11 cases that performed mitral valve replacement due to incomplete reconstruction were excluded). Material and Method : From March 1991 to March 2001, 38 patients underwent mitral valve repair due to mitral valve regurgitation with or without stenosis. Mean age was 47.6$\pm$14.7 years(range 15 to 70 years) : 11 were men and 27 were women. The causes of mitral valve regurgitation were degenerative in 14, rheumatic in 21, infective in 2 and the other was congenital. Result : According to the Carpentier's pathologic classification of mitral valve regurgitation, 3 were type 1 , 16 were type II and 19 were type III. Surgical procedures were annuloplasty 15, commissurotomy 19, leaflet resection and annular plication 9, chordae shortening 11, chordae transfer 5, new chordae formation 2, papillary muscle splitting 2 and vegetectomy 2. These procedures were combined in most patients. There were 2 early death and the causes of death were respiratory failure, renal failure and sepsis. There was no late death. Valve replacement was done in 6 patients after repair due to valve insufficiency or stenosis 3 weeks, 1, 3, 51, 69, 84months later respectively. These patients have been followed up from 1 to 116 months(mean 43.0 months). The mean functional class(NYHA) was 2.36 pre-operatively and improved to 1.70. Conclusion : In most cases of mitral valve regurgitation, mitral valve reconstruction when technically feasible is effective operation that can achieve stable functional results and low surgical and late mortality.

Cabrol Technique Application in Off-pump Coronary Artery Bypass Grafting Using Radial Artery (인공심폐기를 이용하지 않는 관상동맥우회술 시 요골동맥을 이용한 Cabrol 술식의 응용)

  • Na, Chan-Young;Oh, Sam-Se;Kim, Soo-Cheol;Kim, Jae-Hyun;Jo, Won-Min;Seo, Hong-Ju;Lee, Cheul;Chang, Yun-Hee;Kang, Chang-Hyun;Lim, Cheong;Baek, Man-Jong;Whang, Song-Wok;Choi, In-Seok;Kim, Woong-Han;Park, Yoon-Ock;Moon, Hyun-Soo;Park, Young-Kwang;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.630-632
    • /
    • 2003
  • In off-pump coronary artery bypass grafting (CABG), multiple proximal anastomosis may increase the risk of cerebral embolism (air, debris) and aortic injury (dissection, pseudoaneurysm). Radial artery (RA) has no intraluminal valve such as saphenous vein. We applied Cabrol technique using aortic root replacement for proximal anastomosis in off-pump CABG. Cabrol technique using RA graft can reduce numbers of proximal anastomosis and reduce number of aortic manipulation in off-pump CABG. We report a Cabrol technique for proximal anastomosis in off-pump CABG with RA graft.

Clinical Study of 80 Cases of Mitral Valve Operations Via Extended Transseptal Approach (확장시킨 경중격 절개방식을 통한 승모판 수술의 80례 임상 분석)

  • 김학제;황재준;최영호;손영상;김욱진;김태식;김현구
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1037-1042
    • /
    • 1998
  • Background: Among the various techniques for the adequate exposure of the mitral valve, the extended transseptal approach is the essential prerequisite for accurate repair or replacement of the mitral apparatus. But the efficacy and safty of the extended transseptal approach has not determined in Korea yet. Materials and methods: Retrospective data of 80 consecutive patients, operated from September 1992 to July 1997 were reviewed. Seventy- eight patients underwent mitral valve replacement and 2 patients underwent excision of left atrial myxoma. Thirty-eight of 78 patients had other concomitant procedures such as aortic valve replacement(n=22), tricuspid annulopasty(n=14), coronary artery bypass graft(n=1) and closure of ventricular septal defect(n=1). Mean follow up was 23.3±15.0 months and total follow up was 1792 patient-months. Results: The hospital mortality rate was 3.8%(3 patients). Two deaths were due to low cardiac output and one due to postoperative bleeding of coagulopathy. Among the 46 patients who had atrial fibrillation preoperatively, 45 had atrial fibrillation postoperatively and 1 converted to sinus rhythm. All 34 patients who were in normal sinus rhythm preoperatively remained in sinus rhythm after the operation. Mean aortic cross clamping time was 62 minutes for isolated mitral procedure and 90 minutes for concomitant procedures. There were no specific complications related to this approach. Conclusions: We suggest that the extended transseptal approach is an easy and good method for mitral valve surgery, especially in patients with small sized left atrium.

  • PDF

Aortic Translocation for Complete Transposition of the Great Arteries with a Ventricular Septal Defect and Pulmonic Stenosis (심실 중격 결손과 폐동맥 협착을 동반한 완전 대혈관 전위에서 대동맥 전위술)

  • Jeong, In-Seok;Lee, Chang-Ha;Lee, Cheul;Lim, Hong-Gook;Kim, In-Sub;Youn, Hyo-Chul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.476-479
    • /
    • 2008
  • The Rastelli operation has been a standard procedure for repairing complete transposition of the great arteries combined with a ventricular septal defect and pulmonary stenosis. Yet this procedure has several shortcomings, including the risk of incurring left ventricular outflow tract obstruction on long-term follow-up. In this regard, aortic translocation has recently been regarded as a potent alternative to Rastelli's operation. We report here on a case of complete transposition of the great arteries that was combined with an inlet-extended perimembranous ventricular septal defect and pulmonary stenosis in a 2-year-old boy. All the problems were successfully repaired using the aortic translocation technique. Postoperative echocardiography showed a straight and wide left ventricular outflow tract.

The Clinical Experiences of "New Duromedics Valve" Replacement (새로운 Duromedics 인공판막 치환의 임상고찰)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Yun, Chi-Sun;Park, Han-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.979-985
    • /
    • 1997
  • Between October 1991 and May 1995, 256 "New Duromedics Valve"(Edward TEKNA Bileaflet Valve) were implanted in 208 adult patients(171 mitral, 82 aortic and 3 tricuspid) with age ranging from 18 years to 70 years(mean 48.2$\pm$ 11.6 years). Postoperative complication rates were 12.2%, but there was none valve related one. Overall early mortality rate were 1.4%(1.6% for MVR, 2.1% for DVR, and none for AVR or TVR) respectively. Follow-up was 99% completed ranging in duration from 2 months to 46 months. There were 6 valve-related late complications(2.9%) with 2 patients with upper gastrointestinal bleeding, 2 with cerebral thxomtioembolism, 1 with valve thrombosis and 1 with valve endocarditis. Freedom from these valve-related major complications were 89.9% at 40 months. There were 5 late deaths(2.4%). one of these late deaths was considered valve-related. Overall actuarial survival rates at 40 months were 95.5%, 96.8% for mitral, 97.1% for aortic, 100% for tricuspid, and 92.0% for double valve replacement respectively. Preoperative New York Heart Association functional class were 2.9, and 1.3 in post-operative state. We have been trying to keep the international normalized ratio(INR) with range of 2.5 to 3.0. The INR of 4 patients of 5 with anticoagulant ralated complications was beyond the range. To reduce the rate of anticoagulant related complications, we felt very strongly that the INR should be kept between 2.5 and 3.0. In our cases, there was no structural failure or significant hemolysis in the absence of periprosthetic leak. This experience encourages us to continue using the "New Duromedics Valve".omedics Valve".uot;.

  • PDF

Comparision of Inclusion TechnicRue with Open Technique in Patients with Bentall Procedures (Bentall수술에서 inclusion technique 과 open technique의 비교)

  • 김정택;문준호
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.506-511
    • /
    • 1997
  • To understand the clinical results of aortic root replacement with either inclusion or open technique, we analysed 53 patients who underwent replacement of the aortic root with composite graft between October,1980, and May, 1995. Annuloaortic ectasia was the most common indication for operation(29 patients), follwed by aortic dissection(22 patients). Among 53 patients, 19(35%) had Marfan syndrome. Three patients died during hospitalization (Mortality: 5.5%). The follow up was possible in 48 patients(Follow-up rate; 94%,mean duration;37 months). The actuarial survival rate at 24 months was 95% in open technique group, and 87% in inclusion technique group. Late complications developed in 10 patients. Dissecting aneurysm in the remaining aorta was noted in 3 patients with inclu ion 1,schnique, and a pseudoaneurysm from coronary artery anastomosis site developed in a patient with inclusion technique. In conclusion, there was no statistical differences in survival for 24 months between inclusion technique and open technique group. But late problems in the remaining aorta or death from unknown cause occurred with moderate frequency : careful follow-up after aortic root replacement thought to be important for long term survival.

  • PDF