• Title/Summary/Keyword: 대동맥 판막

Search Result 322, Processing Time 0.035 seconds

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

Anatomical Structures of the Aortic Root in Koreans (한국인 대동맥 근부의 해부학적 구조)

  • Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Kim, Si-Wook;Kim, Su-Il;Chung, In-Hyuk;Na, Myung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.321-328
    • /
    • 2007
  • Background: It is very important to determine the surgical anatomy of the aortic root when performing spreading aortic root preserving heart surgery. This study focuses on the surgical aspect of the aortic root anatomy by performing dissection of Korean cadavers. Material and Method: The subjects were 62 cadavers. We measured the intercommissural distances, heights of the sinuses and the circumference of the sinotubular junction and the aortic annulus. Result: The mean age of death was 61.3 years. The intercommissural distance for the right coronary sinus was $0.73{\pm}2.23mm$, that for the non coronary sinus was $19.34{\pm}2.03mm$, and that for the left coronary sinus was $18.58{\pm}2.15mm$. The height of sinus was $20.59{\pm}2.48mm$ for the right coronary sinus, $18.61{\pm}2.26mm$ for the non coronary sinus and $17.95{\pm}19mm$ for the left coronary sinus. The circumference of the sinotubular junction was $70.73{\pm}5.94mm$ and that of the aortic annulus was $77.94{\pm}5.63mm$. There is no correlation between age and STJ, aortic annulus and the ratio of STJ of aortic annulus respectively (p=0.920, p=0.111, p=0.073). The tilting angle of the sinotubular junction and aortic annulus is from $2.03^{\circ}$ to $7.77^{\circ}$ $(mean=4.90^{\circ})$. Conclusion: The intercommissural distance and the height of the sinus were largest in the right coronary sinus, and the position of the sinotubular junction to the aortic annulus is obliquely tilted levo-posteriorly.

Avulsion of Aortic Commissure: Rare Cause of Aortic Regurgitation - 2 case reports - (교련부 분리에 의해 발생한 대동맥판 역류 - 치험 2예 -)

  • Choi, Jae-Woong;Hwang, Ho-Young;Choi, Eun-Suk;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.777-780
    • /
    • 2009
  • We reported here on 2 cases of aortic regurgitation (AR) that were due to avulsion of the aortic valve commissure. Aortic valvuloplasty was attempted in both cases. In the 1st case, valvuloplasty was performed with reattaching the commissure using the 5-0 polypropylene continuous suture technique. However, aortic regurgitation recurred and this lead to reoperation on the postoperative $14^{th}$ day. The intraoperative finding revealed a completely re-detached commissure that required mechanical valve replacement. In the second case, we attempted to reattach the commissure using pledgetted multiple transverse mattress sutures with 5-0 polypropylene. Because the leaflet coaptation was incomplete, the aortic valve was replaced with a tissue valve.

Dysfunction of the Prosthetic Aortic Valve in Idiopathic Hypereosinophilic Syndrome -A case report - (인공 대동맥판막 기능부전을 일으킨 특발성 과호산구 증후군 -1예 보고-)

  • Yoo, Dong-Gon;Sung, Kyu-Wan;Jung, Sang-Sig;Kang, Gil-Hyun;Kim, Chong-Wook;Park, Chong-Bin
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.297-300
    • /
    • 2007
  • Idiopathic hypereosinophilic syndrome is a rare systemic, leukoproliferative disorder characterized by eosinophilmediated tissue injury causing multiple organ failure, including the heart. Cardiac involvement occurs in more than 75% of patients with hypereosinophilic syndrome. Cardiac manifestations include subendocardial fibrosis, thrombus leading to peripheral emboli, restrictive cardiomyopathy, and valvular dysfunction. It is more common in men than in women (9 : 1), and trends to present between the ages of 20 and 50 years. Presentation in childhood is unusual. We report for the first time a case of a 58-year-old man with idiopathic hypereosinophilic syndrome manifested by prosthetic aortic valve dysfunction that was successfully treated by steroid and hydroxyurea therapy after surgical valvular replacement.

Aortic Root Replacement in Patient of Right Ventricular Hypoplasia with Annuloaortic Ectasia, Ventricular Septal Defect and Aortic Regurgitation - Report of 1 case - (대동맥판륜 확장증, 심실중격결손 및 대동맥판막 폐쇄부전과 동반된 우심실 저형성 환자에서 대동맥근부 치환술 -1예 보고)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kang, Sang-Soo;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.510-513
    • /
    • 2003
  • Annuloaortic ectasia, aortic regurgitation(AR), and ventricular septal defect(VSD) in patients with right ventricular hypoplasia is a very rare condition. We report a patient who underwent aortic root replacement with a composite graft for annuloaortic ectasia associated with VSD and AR in right ventricular hypoplasia. The patient was a 19 year-old male. Transthoraic echocardiogram and cardiac catheterization revealed a perimembranous VSD (2 cm in diameter), severe AR, annuloaortic ectasia, bipartite right ventricle with hapoplasia, and hypoplastic tricuspid valve. Operative findings showed that free margins of the right and noncoronary cusps were markedly elongated, thickened, and retracted, and commissure between the right coronary cusp and the noncoronary cusp was fused and calcified. VSD was closed with an autologous pericardial patch and composite graft aortic root replacement using direct coronary button reimplantation was performed, and the hypertrophic muscle of the right ventricular outflow tract was resected. The patient had transient weaning failure of cardiopulmonary bypass and was discharged at the postoperative 14 days without any problems.

Aortic Valve Replacement with Patch Enlargement of Aortic Annulus in Aortic Stenosis with small aortic Annulus. (소 대동맥 판막륜을 가진 대동맥판막 협착증 치험 1례 보고)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.663-666
    • /
    • 1985
  • Whatever a surgeon choose aortic prosthesis in aortic stenosis, it will always provoke some degree of obstruction to flow due to its smaller effective orifice area to tissue annulus. Occasionally, we meet small aortic annulus to his or her body surface area in aortic valve replacement. The small annulus remains a problem in that both tissue and mechanical prosthesis have significant pressure gradients between LV and aorta in resting or exercising states. In these circumstances, diverse surgical procedures, such as tilting disc prosthesis, supraannular position of aortic prosthesis, and enlargement of aortic root [including aortoventriculoplasty, translocation of aortic valve, & double outlet of LV by valved conduit], were applied. We experienced one case of aortic stenosis with small aortic annulus. Systolic pressure gradients between LV & aorta were 90 mmHg. Diameter of annulus was 19 mm. So we performed patch enlargement of aortic root by Manouguian and AVR with St. Jude medical valve 23 mm.

  • PDF

A case of congenital ductus arteriosus aneurysm (Congenital ductus arteriosus aneurysm 1례)

  • Wang, Sheng Wen;Kim, Ji Eun;Lee, Young Seok;Lee, Young Ah
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1363-1366
    • /
    • 2006
  • Aneurysmal dilatation of the ductus arteriosis has been considered a rare but potentially fatal abnormality. The mechanism of ductal aneurysmal formation remains uncertain. Plain chest radiography has proven helpful in the diagnosis of ductus arteriosus aneurysm (DAA), before the application of transthoracic echocardiography. The transthoracic echocardiography is an important tool for the diagnosis and follow-up of DAA. We present a case of congenital ductus arteriosus aneurysm in a newborn, that was an incidental discovery. The diagnosis was made by echocardiography, three-dimensional surface rendering computed tomography (CT), and spontaneous regression after four weeks of follow-up.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.

Long-term Results after 1,144 CarboMedics Mechanical Valve Implantation (CarboMedics 기계판막을 이용한 1,144예 판막치환술의 장기 성적)

  • Kang, Chang-Hyun;Kim, Kyung-Hwan;Kim, Ki-Boong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.559-569
    • /
    • 2004
  • The CarboMedics mechanical valve has been reported to show acceptable valve-related complication rates. The aim of this study is to evaluate our clinical experience with the CarboMedics valve. Material and Method: Between August 1988 and September 1999, we implanted 1,144 CarboMedics valves in 850 patients (aortic 179; mitral 385; double-valve 234; tricuspid 52). The mean age was 44.5 $\pm$ 12.5 years. Follow-up was completed in 95.2% and median follow-up period was 7.9 years (6753 patient-years). Result: The overall hospital mortality rate was 3.4% and the mortality rate for each group was 1.7% for aortic group, 2.6% for mitral group, 4.7% for double-valve group, and 9.6% for tricuspid group, Tricuspid group showed significantly higher mortality rate than aortic and mitral group (p〈0.05). The actuarial survival at 10 years was 87.1 $\pm$ 2.6%, 88.9 $\pm$ 1.7%, 82.4 $\pm$ 2.9%, and 77.5 $\pm$ 7.0% for aortic, mitral, double, and tricuspid valve group, respectively. Age and tricuspid valve replacement were significant risk factors for long-term survival in multivariate analysis (p 〈 0.05). Freedom from valve thrombosis at 10 years was 99.4 $\pm$ 0.6%, 98.2 $\pm$ 0.8%, 99.2 $\pm$ 0.8%, and 87.6 $\pm$ 0.5% for aortic, mitral, double and tricuspid valve group. Tricuspid valve group showed significantly higher rate of valve thrombosis (p 〈 0.05). Conclusion: Long-term results of our experience demonstrated that CarboMedics valve showed acceptable incidence of valve-related complications. However, tricuspid valve replacement showed higher rate of early mortality and valve thrombosis than other valve replacement groups.