• Title/Summary/Keyword: 대동맥 수술

Search Result 589, Processing Time 0.032 seconds

Adaptive Response to ionizing Radiation Induced by Low Doses of Gamma Rays in Human Lymphoblastoid Cell Lines (인체임파양세포에서 저선량의 감마선에 의해서 유도되는 적응 반응)

  • Seong, Jin-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • When cells are exposed to low doses of a mutagenic or clastogenic agents. they often become less sensitive to the effects of a higher dose administered subsequently. Such adaptive responses were first described in Escherichia coli and mammalian cells to low doses of an alkylating agent. Since most of the studies have been carried out with human lymphocytes, it is urgently necessary to study this effect in different cellular systems. Its relation with inherent cellular radiosensitivity and underlying mechanism also remain to be answered. In this study, adaptive response by 1 cGy of gamma rays was investigated in three human lymphoblastoid cell lines which were derived from ataxia telangiectasia homozygote, ataxia telangiectasia heterozygote, and normal individual. Experiments were carried out by delivering 1 cGy followed by 50 cGy of gamma radiation and chromatid breaks were scored as an endpoint. The results indicate that prior exposure to 1 cGy of gamma rays reduces the number of chromatid breaks induced by subsequent higher dose (50 cGy), The expression of this adaptive response was similar among three cell lines despite of their different radiosensitivity. When 3-aminobenzamide, an inhibitor of poly (ADP-ribose) polymerase, was added after 50 cGy, adaptive responses were abolished in all the tested cell lines. Therefore it is suggested that the adaptive response can be observed in human lymphoblastoid cell lines, which was first documented through this study. The expression of adaptive response was similar among the cell lines regardless of their radiosensitivity. The elimination of the adaptive response by 3-aminobenzamide is consistent with the proposal that this adaptive response is the result of the induction of a certain chromosomal repair mechanism.

  • PDF

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Early Result of Proximal Anastomosis Methods of Radial Artery in Coronary Artery Bypass Surgery (관상동맥우회술 시 요골동맥의 근위부 문합방법에 따른 조기결과)

  • Park Jong Un;Shin Yoon Cheol;Kim Eung-Jung;Chee Hyun Keun
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.91-98
    • /
    • 2006
  • Background: There are many different opinions regarding the proximal anastomotic sites of radial artery in coronary artery bypass surgery. Therefore, we compared the clinical and angiographic findings according to anastomosis of radial artery to develop a guideline. Material and Method: From January 2003 to December 2004, 48 patients who underwent coronary artery bypass surgery using radial artery in Kangdong Sacred Heart Hospital were studied for clinical and coronary angiographic findings and were divided into group I for radial artery that anastomsed to aorta independently and group II that anastomosed to left internal mammary artery. Result: Patients in group I were 33 (men 26, women 7; mean age 61.93$\pm$6.56) and group II were 15 (men 13, women 2; mean age 59.53$\pm$6.02) and there was no difference in preoperative characteristics. Patients in group I had longer cardiopulmonary bypass time (169.36$\pm$40.28 versus 139.40$\pm$20.45, p=0.026) and patients in group II had more sequential grafts with RA per patients (5/33 versus 11/15, p < 0.05). Patients in group I used more vein graft for distal anatstomosis (47/117 ($40\%$) versus 9/48 ($18\%$), p=0.011) and there was no difference in perioperative outcome and overall survival. Mean follow-up time was 15.87$\pm$7.33 (1 to 28) months in patients of the group I and 21.40$\pm$2.85 (17 to 25) months in group II. Postoperative coronary angiography was performed 17/33 ($51.5\%$) in group I and 14/15 ($93.3\%$) in group II. Early perfect patency rate was not statistically different in left anterior descending artery (15/17 ($88.2\%$) versus 2/14 ($85.7\%$), p=1.00) and radial artery (17/20 ($85\%$) versus 30/30 ($100\%$), p=0.058). Late mortality was 1/33 ($3.0\%$) in group I and 1/15 ($6.7\%$) in group II. Conclusion: There was no difference in terms of clinical and postoperative angiographic findings except in cardiopulmonary bypass time, the number of sequential grafts with the RA per patients and the number of the used vein graft.

Clinical Analysis to the Early Results of the CABG (관상동맥우회술의 조기 성적에 대한 임상적 고찰)

  • Kim, Dae-Sig;Yang, Jin-Young;Koo, Won-Mo;Moon, Seung-Chul;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1043-1048
    • /
    • 1998
  • Background: As coronary arterial disease is increasing, we evaluated the patients who underwent CABG(Coronary Artery Bypass Grafting) and thus report the early results and risk factors related to mortality and morbidity. Materials and methods: Between July 1996 and February 1998, 42 patients underwent CABG. We analyzed age, sex, preoperative ejection fraction, Canadian heart classification, prevalence factors of CAD(Coronary Artery Disease), angiographic findings, graft vessel numbers, IMA(Internal Mallary Artery) use, ECC* (extracorporeal circulation) time and morbidity. We also evaluated the mortality rate and the causes of death. Results: Complication was developed at 17cases. The average age of the complication group was 61±11.9 years and that of the noncomplication group was 51±10.5 years(p=0.004). ECC time was 198±42.5(min) in the complication group and 158±47.4(min) in the noncomplication group(p=0.008). The other factors had no correlation to the morbidity, statistically. The average follow up duration was 12.5 months and all the patients were alive except for the 2 expired cases. The mortality rate was 4.7%, among which one patient who underwent CABG with aortic valve replacement died due to multiorgan failure and the other died due to sepsis with pneumonia and wound infection. Conclusions: We conclude that the risk factors related to morbidity were age and ECC time, and that there were no correlations between other factors and morbidity.

  • PDF

Clinical Analysis of Mitral Valve Repair with Artificial Chordae (인공 건삭을 이용한 승모판성형술의 임상적 고찰)

  • 이석기;김정중;오삼세;백만종;나찬영;김욱성
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.768-773
    • /
    • 2004
  • Failure of mitral valve repair sometimes may be ascribed to severe or progressive alteration of the subvalvar apparatus. The aim of this study was to evaluate the effects of new chordae formation on mitral repair. Material and Method: From March 1997 to february 1999, 26 patients underwent mitral valve repairs with new chordae formation, we compared the symptoms and echocardiographic findings checked at preoperative state, and intraoperative period, discharge, and their last OPD visit. There were 45 male, and 11 female patients, and their mean age was 51.2$\pm$43.4 years. Etiology of the lesions was degenerative (18), rheumatic (6), infective (1) and ischemic (1). Chordal lesions were caused by rupture (18), elongation (6), and a combination of two causes (2). Associated lesions included atrial septal defect (2), tricuspid insufficiency (7), aortic insufficiency(4), and a combination of previous two factors (2). The number of mean artificial chordae was 3.6$\pm$1.6. Annuloplasty was per-formed in all cases. The CPB time was 182,1$\pm$63.7 minutes and the ACC time was 133.1$\pm$45.6 minutes. Aver-age follow up period was 49.2$\pm$7.1 months. Result: There was no early death. Early reoperation was performed in bud patients, one patient received mitral valve replacement because of an abnormality of annuloplasty and ano-ther received pericardiostomy due to postoperative pericardial effusion. During the follow up of 49.2$\pm$7.1 moths, there was no late mortality. Postoperative NYHA functional class checked at last OPD visit was class I in 22 patients (88%), class II in 2 (8%), and class III in 1 (4%). Regarding the late echocardiogram MR was absent in 20 patients (78%), 1 in 4 (15%), and II in 1 (4%). The postrepair mitral valve area was 2.2$\pm$0.35 $\textrm{cm}^2$ Conclusion: This study suggests that mitral valve repair using new chordae formation provides good early and mid term survivals and functional improvement. We think that the artificial chorda formation with polytetrafluoroethylene suture might be safe and effective technique for mitral valve repair.

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

Growth of $LiTaO_3$ and Fe doped-LiTaO3 single crystal as holographic storage material (홀로그래피 소자재료 $LiTaO_3$단결정 성장)

  • 김병국;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.193-204
    • /
    • 1998
  • The single crystal of the $LiTaO_3$has large electro-optic effects, so it is applied to optical switch, acousto-optic deflector, and optical memory device as hologram using photorefractive effect. In this study, optic-grade undoped $LiTaO_3$and Fe:LiTaO$LiTaO_3$single crystals were grown by the Czochralski method and optical transmission and absorption spectrums were measured in the wavelength of UV-VIS range. The curie temperature was determined with DSC and by measuring capacitance for the grown undoped crystal and ceramic powder samples of various Li/Ta ratio. In case of having a 48.6 mol% $Li_2O$ as a starting Li/Ta ratio, the results of concentration variations were below 0.01 mol% $Li_2O$ all over the crystal, so it was confirmed that $LiTaO_3$single crystals were grown under congruent melting composition having optical homogeneity. The curie temperature of the Fe:$LiTaO_3$crystal was increased with increased with increased doped Fe concentrations;by the ratio of $7.5^{\circ}C$ increase per Fe 0.1 wt%. Also, the optical transmittance was about 78 %, which was sufficient for optical device.

  • PDF

Establishment of Valve Replacement Registry and Risk Factor Analysis Based on Database Application Program (데이터베이스 프로그램에 기반한 심장판막 치환수술 환자의 레지스트리 확립 및 위험인자 분석)

  • Kim, Kyung-Hwan;Lee, Jae-Ik;Lim, Cheong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2002
  • Background: Valvular heart disease is still the most common health problem in Korea. By the end of the year 1999, there has been 94,586 cases of open heart surgery since the first case in 1958. Among them, 36,247 cases were acquired heart diseases and 20,704 of those had valvular heart disease. But there was no database system and every surgeon and physician had great difficulties in analysing and utilizing those tremendous medical resources. Therefore, we developed a valve registry database program and utilize it for risk factor analysis and so on. Material and Method: Personal computer-based multiuser database program was created using Microsoft AccessTM. That consisted of relational database structure with fine-tuned compact field variables and server-client architecture. Simple graphic user interface showed easy-to-use accessability and comprehensibility. User-oriented modular structure enabled easier modification through native AccessTM functions. Infinite application of query function aided users to extract, summarize, analyse and report the study result promptly. Result: About three-thousand cases of valve replacement procedure were performed in our hospital from 1968 to 1999. Total number of prosthesis replaced was 3,700. The numbers of cases for mitral, aortic and tricuspid valve replacement were 1600, 584, 76, respectively. Among them, 700 patients received prosthesis in more than two positions. Bioprosthesis or mechanical prosthesis were used in 1,280 and 1,500 patients respectively Redo valve replacements were performed in 460 patients totally and 40 patients annually Conclusion: Database program for registry of valvular heart disease was successfully developed and used in personal computer-based multiuser environment. This revealed promising results and perspectives in database management and utilization system.

Immediate Reoperation for Failed Mitral Valve Repair (승모판막성형술 실패 직후에 시행한 재수술)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Wook-Sung;Lee, Young-Tak;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.929-936
    • /
    • 2003
  • We analysed the surgical outcomes of immediate reoperations after mitral valve repair. Material and Method: Eighteen patients who underwent immediate reoperation for failed mitral valve repair from April 1995 through July 2001 were reviewed retrospectively. There were 13 female patients. The mitral valve disease was regurgitation (MR) in 12 patients, stenosis (MS) in 3, and mixed lesion in 3. The etiologies of the valve disease were rheumatic in 9 patients, degenerative in 8, and endocarditis in 1. The causes of reoperation was residual MR in 13 patients, residual MS in 4, and rupture of left ventricle in 1. Fourteen patients had rerepair for residual mitral lesions (77.8%) and four underwent replacement. Result: There was no early death. After mean follow-vp of 33 months, there was one late death. Echocardiography revealed no or grade 1 of MR (64.3%) in 9 patients and no or mild MS in 11 patients (78,6%). Reoperation was done in one patient. The cumulative survival and freedom from valve-related reoperation at 6 years were 94% and 90%, respectively. The cumulative freedom from recurrent MR and MS at 4 years were 56% and 44%, respectively. Conclusion: This study suggests that immediate reoperation for failed mitral valve repair offers good early and intermediate survival, and mitral valve rerepair can be successfully performed in most of patients. However, because mitral rerepair have high failure rate, especially in rheumatic valve disease, adequate selections of valvuloplasty technique and indication are important to reduce the failure rate of mitral rerepair.