• Title/Summary/Keyword: 대기오염 물질

Search Result 1,789, Processing Time 0.031 seconds

Ozone Generation and NO Gas Removal Characteristics a Silent-Surface Hybrid Discharge Type Ozonizer (무성-연면 복합방전형 오존발생기의 오존생성 및 NO 가스 제거특성)

  • Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.32-38
    • /
    • 2005
  • A hybrid discharge type ozonizer, which is superposed silent and surface discharges, has been designed and manufactured to apply for Nitrogen Oxides(NO) gas removal. The ozonizer consists of three electrodes, and is classified three types of ozonizer by changing applied voltage. Investigation was carried out variance with the flow rate of supplied oxygen gas, discharge power and the sorts of superposed discharge type ozonizer. Moreover, NO(1200[ppm])/$N_2$ gas removal investigation was also conducted to apply for environment improvement field. Two kinds of NO gas removal investigations were conducted. It distinguishes the investigations into NO gas reaction method. According to these studies, maximum removal rate of 100[%] in NO gas was obtained, and 8334[ppm] and 3249[mg/h] of maximum ozone concentration and generation were also obtained respectively.

Environmental Sensor Monitoring System of Subway Stations Using USN (USN을 이용한 지하철 역사 대기환경 모니터링 시스템)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • The$PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, an USN monitoring system is implemented to display and record the data of $PM_{10}$, CO/$CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, 2.4GHz Zigbee, 424MHz wireless communication, and CDMA M2M method are applied and evaluated.

Characteristics of Hazardous Air Pollutant Level in Road Tunnels in Seoul (서울시 터널의 유해대기오염물질 농도변화 특성 분석)

  • Park, Jin-A;Lee, Won-Young;Kim, Jin-A;Kim, Ik-Su;Kim, Hyun-Su;Jeong, Jong-Heup;Yun, Jung-Seop;Jung, Kweon;Eom, Seog-Won
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.6
    • /
    • pp.541-549
    • /
    • 2013
  • Objectives: We analyzed the characteristics of hazardous air pollutants (HAPs) in road tunnels in Seoul. Methods: Particle matter ($PM_{10}$), elemental carbon (EC), organic carbon (OC), and 16 species of polycyclic aromatic hydrocarbons (PAHs) in two road tunnels (NS tunnel and HJ tunnel) were sampled and analyzed from 2007 to 2011. Results: Levels of $PM_{10}$ and carbon ingredients which were mainly emitted from diesel-fueled vehicles showed a declining tendency in both road tunnels. PAHs levels in HJ were declining slightly while PAHs levels in the NS tunnel fluctuated considerably and showed an increasing tendency. Conclusions: These results suggested that the abatement project of diesel vehicle emissions by the Seoul metropolitan government from 2007 has had an impact on the reduction of DVE into the air, though there exist many things to consider for analyses.

Concentration Response Functions for Particulate Matter related Health Risk Assessment in South Korea (입자상 대기오염물질의 건강 위해성 평가를 위한 국내 농도반응함수 도출)

  • Ha, Jongsik
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.202-213
    • /
    • 2017
  • Objectives: HRA (Health Risk Assessment) is an important tool for measuring the health impacts of air pollution. HRA is already being used widely as an important reference for crafting air pollution policies. However, the absence of a domestic CRF (Concentration Response Function) standard, which is a main component for HRA, could cause confusion amongst policy-makers. The purpose of this study is to tabulate a domestic CRF standard for a PM (Particulate Matter)-related HRA. Methods: This study suggested a domestic CRF standard for HRA thorough a literature review. The literature review for meta-analysis was limited to the English language for epidemiological studies published from January 1980 to March 2016. This meta-analysis was conducted by assuming both fixed- and random-effects of CRF. In addition, studies that reported HRA of air pollution for WHO (World Health Organization), the EC (European Commission), and the EPA (Environmental Protection Agency) were reviewed to compare the CRFs of South Korea to the recommended CRFs of WHO, the EC, or the EPA. Additionally, a domestic CRF standard was supplemented by these. Results: Nineteen studies were selected for the CRF for South Korea. Fifty-three CRFs were derived for meta-analysis. CRFs with a standard for PM-related HRA were divided according to the following four criteria: air pollution, exposure characteristics, type of health impact, and age group. Finally, a domestic CRF standard was created comprised of 21 CRFs. Among these, six CRFs were derived from the results of foreign HRA studies. Conclusions: This study is important in that a domestic CRF standard is first suggested. In addition, this study suggests a further area of study for using HRA as a policy tool and a direction of epidemiological study.

Atmospheric Acidic Deposition: State of Acid Rain in Korea and the World (대기산성강하물: 한국과 세계의 산성비 실태)

  • Kim, Joon-Ho
    • The Korean Journal of Ecology
    • /
    • v.28 no.3
    • /
    • pp.169-180
    • /
    • 2005
  • Nitrogen dioxide concentration was being grown ca. 8% per year although sulphur dioxide concentration was being reduced ca. 10% per year in Seoul from 1996 to 2003. The rainwater was heavily acidic with pH 4.19 to 4.68 in Seoul during 1980 to 1991. Acidity score on the basis of the total anion concentration of rainwater follows the higher in sequence with Seoul(Kwanaksan)(341.5 ${\mu}equiv{\cdot}L^{-1}$), Gwangneung(199.2 ${\mu}equiv{\cdot}L^{-1}$) and whole Korea mean(10.3 ${\mu}equiv{\cdot}L^{-1}$). Rainwaters from 38 sampling sites of 16 countries in the world, on the basis of the acidity score, are classified and designated as five acid rain grades(ARG): the least score is founded in Tana Rata(16.2 ${\mu}equiv{\cdot}L^{-1}$), Malaysia where has the best rain but the greatest founded in Chongquing(541.1 ${\mu}equiv{\cdot}L^{-1}$), China where has the worst rain in the world. Even though acidic deposition decrease with time in the world generally, it is expected to increase in Asia, Africa and Mid-South America.

Estimation of Air Pollutant Emissions for the Conversion of Diesel to CNG in the Busan Metropolitan Area (부산지역 경유버스를 CNG버스로 대체시 발생하는 대기오염물질 배출량 산정 및 변화 분석)

  • Bang, Jin-Hee;Kang, Yoon-Hee;Song, Sang-Keun;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.21 no.2
    • /
    • pp.241-251
    • /
    • 2012
  • The emissions of several air pollutants ($NO_x$, CO, VOCs, etc.) for the replacement of all diesel buses by Compressed Natural Gas (CNG) buses were estimated in the Busan Metropolitan Area (BMA). These emissions were calculated from emission factors considering the different driving speeds with bus routes, distance traveled, and deterioration factors. For the purpose of this study, three categories of fuel type were selected: (1) the combination of diesel (65%) and CNG buses (35%) (DSL+CNG case), (2) all diesel buses (DSL case), and (3) all CNG buses (CNG case). The emissions of $NO_x$ and CO in the CNG case were estimated to be significant decreases (by about 50% and 98%, respectively) relative to the DSL case. Conversely, the emission of VOCs (980.7 ton/year) in the CNG case were a factor of 3.3 higher than that (299.8 ton/year) in the DSL case. In addition, the diurnal variations of emissions between two city buses (e.g. diesel and CNG) and all other vehicles were distinctly different because the two city buses operate at a regular time interval. Our overall results suggest the possibility that the pollutant emissions from the CNG buses can exert less influence on air quality in the target area than those from the diesel buses.

Effective Diffusion Coefficient in the Porous Media (다공성 미디아에 있어서 유효확산계수)

  • Jeehyeong Khim
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.2
    • /
    • pp.83-90
    • /
    • 1996
  • A diffusion process is often the main mechanism of soil gas/vapor movement in the vadose zone. The diffusion coefficients in the porous soil media are different from those in the free air phase by the reduction of available area for diffusion, tortuous diffusion path and variable cross section area along the diffusion path. To take account those effects of the diffusion process in the porous media, usually the terms of effective diffusion coefficient and tortuosity are have been used. However, as there are many differents definitions for the tortuosity, when the term of tortuosity is used, it is necessary to examine it throughly. Moreover, there are many different equations for the effective diffusion coefficient according to the investigators and the differences in the values of effective diffusion coefficients between the equations are not insignificant, the selection of the equation should be done with caution. In this paper, the different definitions of effective diffusion coefficient are examined and discussed. As well as definitions, the lots of availabe models for the diffusion coefficient in terms of porosities are compared. Also, the constrictiviy which explains the effect of cross sectional area change over the diffusion path was discussed.

  • PDF

A Study on Contaminant Emission and Combustion of Anthracite-Bituminous Coal Blend in a Fluidized Bed Coal Combustor (유동층 연소로에서 유$cdot$무연탄 혼합 연소시 대기오염물질 배출에 관한 연구)

  • 조상원;정종현;손병현;김영식;오광중
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.28-36
    • /
    • 1996
  • The objects of this study were to investigate emissions of air pollutant the particles as well as the combustibility of the low grade domestic anthracite coal and imported high-calorific bituminous coal in the fluidized bed coal combustor. The production of air pollution from anthracite-bituminous coal blend combustion in a fluidized bed coal combustor was evaluated. The effects of air velocity and anthracite fraction on the reaching time of steady state condition was also evaluated. We used coal samples the domestic low grade anthracite coal with heating value of 2,010 kcal/kg and the imported high grade bituminous coal with heating value of 6,520 kcal/kg. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 0.3 m/s which was the fastest. It has been found that $O_2$ and $CO_2$ concentration were reached steady state at about 100 minute. As the height of fluidized bed becomes higher, the concentration s of $SO_2$ and $NO_x$ mainly increased. The concentration of freeboard was the highest and emission concentration was diminished. Also, as anthracite fraction increased, the emission of $SO_x$ concentration was increased. But, it has been found that the variation of $NO_x$ concentration with anthracite fraction was negligible and the difference of emission concentration according to air flow rates was negligible, too. It has been found that $O_2$ concentration decreased and $CO_2$ concentration increased as the height of fluidized bed increased. As anthracite fraction increased, the mass of elutriation particles increased, and $CO_2$ concentration decreased. Also, as air velocity increased, $O_2$ concentration decreased and $CO_2$ concentration increased. Regardless-of anthracite fraction and flow rate, the combustible weight percentage in elutriation particles were high in the case of fine particles.

  • PDF

철도의 환경 친화성 분석에 대한 연구;대기오염물질 배출량 및 에너지 소비율 중심으로

  • Kim, Hui-Man
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.34-39
    • /
    • 2006
  • 1. 철도, 도로, 항공, 해운 등 교통수단별 현황을 조사한 결과, 현재까지의 교통정책이 도로교통 우선 위주였기 때문에 철도는 뛰어난 환경성 및 경제성을 가지고 있음에도 불구하고 수송분담율이 비교적 저조한 편이었다. 그러나, 향후 정부의 사회기반시설 구축에 있어서 국가 기간 철도망 확대와 대도시 지하철 및 경량전철 건설을 통한 도심철도망과 간선철도망의 연결 등을 통하여 철도의 이용이 훨씬 용이해질 것으로 보이며 이에 따라 철도의 이용률도 크게 상승할 것으로 예상된다. 2. 교통수단별 일반현황은 다음과 같다. 1) 철도교통은 여객수송량이 다소 증가하고 있는 추세였는데, 2004년 KTX의 개통으로 인하여 여객수송량이 급증하였으나, 화물수송은 약간 감소하는 추세이다. 2) 도로교통은 공로의 경우 이용량이 크게 감소하고 있으나, 자가용의 경우에는 승용차의 급증에 의하여 도로의 분담률이 증가하고 있다. 그러나, 도로망의 확충이 자동차의 증가량을 따르지 못하는 것과 자동차가 도시에 밀집됨에 따른 교통체증에 따라 자가용 차량의 1일 평균 주행거리가 짧아지는 등 수송량이 크게 증가하지는 않고 있다. 3. 각 교통수단별 환경경제성을 조사한 결과는 다음과 같았다. 1) 단위수송량당 에너지 소비율은 여객의 경우 철도가 75.97kcal/인 km에 불과한 반면에 버스는 415.43, 택시는 1,192.24kcal/인 km에 달하여 각각 철도의 5.5배 및 15.7배나 많은 에너지를 소비하는 것으로 나타났다. 화물의 경우에도 철도는 105.98kcal/톤 km에 불과한 반면에 도로는 1,674.21kcal/톤 km에 달하여 철도의 무려 15.8배의 에너지를 사용하는 것으로 나타나, 철도가 에너지 효율성 면에서 도로 교통수단보다 월등히 앞서는 친환경적이면서 경제적인 교통수단임을 알 수 있다. 2) 도로와 철도의 단위수송량 당 CO의 배출량은 도로가 1,531.2kg/백만인 km로 철도의 167.4kg/백만인 km에 비하여 9배나 되었다. 그러나, 탄화수소의 경우는 도로가 216.5kg/백만인 km으로 철도의 68.0kg/백만인 km의 3배를 넘는다. 미세먼지의 경우는 도로가 철도보다 약간 더 많은 수준이었으나, NOx와 $SO_2$는 오히려 철도가 오히려 약간 더 높게 나타났다.

  • PDF

Study of the cap-and-trade system against the air pollutants in the Seoul Metropolitan Area and suggestion for its enforcement throughout South Korea (수도권 대기오염물질 배출권거래제에 대한 고찰 및 총량제 확대 시행을 위한 제언)

  • Park, Min Ha;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.159-171
    • /
    • 2019
  • The cap-and-trade system against the air pollutants in the Seoul Metropolitan Area (SMA), Korea has been implemented since 2008 and will be implemented other areas in Korea on 2020. In this study, to identify the outcome and effectiveness of the cap-and-trade system in the SMA, (1) the rate of change for NOx and SOx emissions, (2) differences between the real emission and allocated amount, and (3) the status of trading are reviewed. It was found that the NOx and SOx emissions from the sources under the cap-and-trade system decreased in the SMA but the reduction was mainly due to the reduction of fuel usage not related to the system. It was found that the average percentage of annual emission in the SMA to the allocated amount between 2008 and 2018 was 66.9% for NOx and 69.3% for SOx, respectively. It suggests that there was over allocation of the emission amounts. The average trading prices in the SMA were 0.193 $/kg for NOx and 0.128 $/kg for SOx, far lower than those in RECLAIM, 131.942 $/kg and 81.677 $/kg, respectively. It was suggested that (1) the cap system for NOx and SOx emissions should be implemented only for the area with high emission ratio from large point sources, (2) the trade system is not suitable for the effective implementation of the cap system, and (3) Korean government should not allow over allocation in order to ensure sound market function without delaying the introduction of technology.