• Title/Summary/Keyword: 대기실

Search Result 186, Processing Time 0.038 seconds

Experimental Performance Validation of an Unmanned Surface Vessel System for Wide-Area Sensing and Monitoring of Hazardous and Noxious Substances (HNS 광역 탐지 및 모니터링을 위한 부유식 무인이동체 시스템의 실험적 성능 검증)

  • Jinwook Park;Jinsik Kim;Jinwhan Kim;Yongmyung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.11-17
    • /
    • 2022
  • In this study, we address the development of a floating platform system based on a unmanned surface vessel for wide-area sensing and monitoring of hazardous and noxious substances (HNSs). For long endurance, a movable floating platform with no mooring lines was used and modified for HNS sensing and monitoring. The floating platform was equipped with various sensors such as optical and thermal imaging cameras, marine radar, and sensors for detecting HNSs in water and air. Additionally, for experiment validation in real outdoor environments, a portable gas-exposure system (PGS) was built and installed on the monitoring system. The software for carrying out the mission was integrated with the Robot Operating System (ROS) framework. The practical feasibility of the developed system was verified through experimental tests conducted in inland water and real-sea environments.

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Proposal for Amendment of the Basic Environmental Policy Act ('BEPA') Article 31 (환경정책기본법 제31조 무과실책임규정의 개정방안)

  • Koh, Moon-Hyun
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.125-147
    • /
    • 2009
  • The Basic Environmental Policy Act (BEPA) (Law No. 4257 effective 1. August 1990) sets forth the basic policies and administrative framework for environmental preservation, leaving more detailed regulations, and emission controls to separate laws targeting air, water, and solid waste, etc. The BEPA Article 31 adopts an unprecedented strict liability standard for damages as an absolute liability. The BEPA Article 31 provides for liability as follows. If a company is alleged to have caused damage through pollution of the environment, it will be liable for damages unless it can show that the pollution did not cause damages, or that it did not actually cause pollution. If the company did cause pollution, and if the pollution is the cause for the damages in question, the company will be liable irrespective of whether it was negligent or otherwise at fault. If there are two or more companies involved in the pollution, but it is unclear which company caused the damages, all of the companies will be jointly and severally liable for the damages. In this paper, the author attempts to uncover the problems of BEPA Article 31 and then seeks desirable amendments by comparing it to the German Environmental Liability Act. First, it will be necessary to provide definitions of 'companies etc.'. Second, it will be necessary to enumerate the kinds of company facilities. Third, it will be necessary to provide exclusionary clauses on material damages. Fourth, it will be necessary to show 'presumption of cause and effect'. Fifth, it will be necessary to provide a clause on 'right to information'. Sixth, it will be necessary to provide a clause for force majeure. Seventh, it will be necessary to take measures to secure abundant liability for damages which can be caused by the owner of the facility, the potential polluter. Finally, it is appropriate that Korea now legislate an Environmental Liability Act akin to the German Environmental Liability Act.

  • PDF

A Study on the Hot Springs(Tangsil Building) of Temporary Palace(Onyanghaenggung) according to the <Oncheonhaenggungdo>(1795) (<온천행궁도(溫泉行宮圖)>(1795)의 온천(탕실) 건축 고찰)

  • LEE Jeongsoo;KIM Ilhwan;LEE Kyeongmi;JI Wonku;CHOI Jaeseong
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.110-123
    • /
    • 2024
  • Onyanghaenggung Palace(temporary palace at Onyang) is an important cultural heritage that can substantially confirm the king's visiting at hot springs based on literature records such as <Ongungyeonggoedae(溫宮靈槐臺)>, <Oncheonhaenggungdo(溫泉行宮圖)> of 『Ongungsasil(溫宮事實)』, <Younggoedaedo(靈槐臺圖)>, 『Younggoedaegi(靈槐臺記)』 and cultural properties such as Yeonggoedae(靈槐臺) and Shinjeong Monument(神井碑). Through a photo taken by Hermann Sander in 1906, it can be confirmed that the hot springs(Tangsil building) at Onyanghaenggung Palace during the Joseon Dynasty was maintained until the early Japanese colonial period. The purpose of this study is to estimate the compositions of the hot springs(Tangsil building) in Onyanghaenggung Palace based on literature records and <Oncheonhaenggungdo>(1795). To achieve these purposes, we firstly examined the changes in Onyanghaenggung Palace and the hot springs (Tangsil building); secondly, the bathing behaviors of kings were reviewed; thirdly, we organized the architectural composition of the hot springs (Tangsil building) according to "Ongung Repair" of 『Ongungsasil (溫宮事實)』; and fourthly, by comparing Sander's photo in the early days of Japanese colonial rule, the architectural composition of the hot springs (Tangsil building) in the late Joseon Dynasty was examined. The results of this study are as follows. First, the hot springs(Tangsil building) of Onyanghaenggung Palace were continuously connected to the Onjeongsil(溫井室) in the reign of King Hyeonjong and maintained until 『Hoseo-eupji』 (1871) in the late Joseon Dynasty. It matches the photograph taken by Hermann Sander(1906) and <1912 Onyang Hot Springs in Asan City>(1912) of Korea Copyright Commission during the early Japanese colonial period. Second, the various king's bathing methods during the Joseon Dynasty were adopted such as washing, spilling and bathing head while sitting on a bathing platform or chair, or exposing the steam of hot spring water, dipping feet into the water and a half-body soaking bath below the navel immersed in water. Third, the stone bathtubs of hot springs(Tangsil building) are composed of the upper bath which was hot spring water gushes out from the northwest, bends to the east, enters the middle bath, and bends to the south to come out to the outside to gather in the lower bath. Around the stone bathtubs, pebble stones brought in from Taean were laid on the floor of the hot springs(Tangsil building). From the above considerations, the compositions of the Tangsil building in Onyang Temporary Palace is based on the king's approach from the main royal building, the king's bathing method and bathing tools, the bathing behavior of enlisted medical officers and bathing assistants, and each rooms mentioned in "Ongung Repair". By comparing it with Hermann Sander's photo, the architectural compositions of the hot springs(Tangsil building) can be estimated.

Effects of Aromatherapy on Depression, Anxiety and the Autonomic Nervous System in Breast Cancer Patients Undergoing Adjuvant Radiotherapy (방사선 요법을 받는 유방암 환자에게 적용한 아로마 요법이 우울, 불안 및 자율신경계 반응에 미치는 효과)

  • Yun, Sun-Hee;Cha, Jung-Hee;Yoo, Yang-Sook;Kim, Yeong-In;Chung, Su-Mi;Jeong, Hea-Lim
    • Journal of Hospice and Palliative Care
    • /
    • v.15 no.2
    • /
    • pp.68-76
    • /
    • 2012
  • Purpose: The study was designed to verify effects of aromatherapy on depression, anxiety and the autonomic nervous system in breast cancer patients who are undergoing adjuvant radiotherapy. Methods: Data were collected from November 2006 through March 2007 at the C university hospital in Seoul. The study included 33 patients and they were assigned to three groups. Group I had aroma oil inhalation for 2 minutes per time, three times a day for six weeks whereas Group II and a control group inhaled aroma oil for 2 minutes per time, once a day for six weeks. For Groups I and II, a mixture of lemon, lavender, rosewood and rose essential oils were used while control group inhaled tea tree oil. Results: Depression was significantly decreased in patients in the experimental groups only. In Groups I and II patients, anxiety level was lower than that in control patients. Patients in Groups I and II also showed stronger physical resistance to stress than control group patients. Conclusion: Aromatherapy should be considered as a method that can significantly decrease depression in breast cancer patients who are undergoing adjuvant radiotherapy.

Psychosocial Impact of Chronic Orofacial Pain (만성 구강안면통증의 사회심리적 영향)

  • Yang, Dong-Hyo;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.397-407
    • /
    • 2009
  • The aim of the study was to evaluate psychosocial impact of non-dental chronic orofacial pain (OFP) on daily living using the graded chronic pain (GCP) scale. It is also investigated the clinical profile such as demographics, event related to initiation of OFP and prior treatments for patients. During previous 6 months since September 2008, 572 patients (M:F=1:1.5, mean age=34.7 years) with non-dental OFP attended university-based specialist orofacial pain clinic (Dankook University Dental Hospital, Cheonan) to seek care although 63% of them already experienced related treatment for their OFP problem. They visited the most frequently general dental practitioner and orthopedic doctors due to their pain problem and medication was the most commonly employed modality. Most of the patients (89.2%) had TMD and the most common related event to initiation of their pain was trauma, followed by dental treatment. Almost half of the patients (46%) suffered from chronic pain(${\geq}6\;M$) and 40% of them exhibited relatively high disability due to chronic OFP. GCP pain intensity and disability days were significantly different for age and diagnosis (p<0.05) but not for gender and duration. GCP grades were affected by all the factors including gender, age, pain duration and diagnosis.(p=0.000) Female gender, elders, and long lasting pain were closely related to high disability. The patients with neuropathic Pain and mixed OFP rather than TMD were graded as being highly disabled. Conclusively, a considerable percentage of chronic OFP patients reports high pain-related disability in their daily, social and work activity, which suggest a need for psychosocial support and importance of earlier referral for appropriate diagnosis and tailored management.

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Distribution and Diversity of Airborne Fungi in Wooden Cultural Heritages Located at Different Geographical Condition : Cases Studies on Seonamsa Temple, Suncheon and Bupjusa Temple, Boeun (입지조건에 따른 목조 문화재의 부유 진균의 분포 및 다양성에 관한 비교 연구: 보은 법주사와 순천 선암사)

  • Hong, Jin Young;Lee, Jeung Min;Kim, Young Hee;Kim, Soo Ji;Jo, Chang Wook;Park, Ji Hee
    • The Korean Journal of Mycology
    • /
    • v.47 no.2
    • /
    • pp.131-142
    • /
    • 2019
  • The Bupjusa and Seonamsa temples are located at places with geographically different condition, and therefore, differ with respect to building's structure and layout. In addition, evident difference can be appeared by the regional climate. For the 2 years, we studied the concentration and diversity of the seasonal airborne fungi inside and outside of the 2 temples. In Seonamsa temple, airborne fungi concentration in the indoor and outdoor air was higher and the species diversity in the indoor air was lower, whereas, concentration variation was larger than that of Bupjusa temple. A total of 173 fungal isolates (including 54 genera) and 162 isolated (including 49 genera) were obtained from the indoor air of Bupjusa and Seonamsa temple, respectively. Whereas, 80 fungal isolates (including 33 genera) and 74 isolates (including 39 genera) were collected form the outdoor air of Bupjusa and Seonamsa temple, respectively. However, more fungal varieties were observed to be distributed inside Bupjusa and outside Seonamsa temples. Amongst all the fungi identified, ascomycetes were more dominant (plus or minus 90% points), followed by basidiomycetes and zygomycetes; which more presented in outdoor air than in indoor air. The airborne fungi concentration in spring (month of April) and autumn was higher than in any other season, for Seonamsa and Bupjusa temples, repectively. Genus Cladosporium was isolated from each site and season, with its dramatic increase noted in autumn. In addition, the highest basidiospore(s) number was obtained after the rain. Consequently, the results suggest that Seonamsa temple was more susceptible to biological damage than Bupjusa temple was.

Investigation on a Way to Maximize the Productivity in Poultry Industry (양계산업에 있어서 생산성 향상방안에 대한 조사 연구)

  • 오세정
    • Korean Journal of Poultry Science
    • /
    • v.16 no.2
    • /
    • pp.105-127
    • /
    • 1989
  • Although poultry industry in Japan has been much developed in recent years, it still needs to be developed , compared with developed countries. Since the poultry market in Korea is expected to be opened in the near future it is necessary to maximize the Productivity to reduce the production costs and to develop the scientific, technologies and management organization systems for the improvement of the quality in poultry production. Followings ale the summary of poultry industry in Japan. 1. Poultry industry in Japan is almost specized and commercialized and its management system is : integrated, cooperative and developed to industrialized intensive style. Therefore, they have competitive power in the international poultry markets. 2. Average egg weight is 48-50g per day (Max. 54g) and feed requirement is 2. 1-2. 3. 3. The management organization system is specialized and farmers in small scale form complex and farmers in large scale are integrated.

  • PDF

The study on outpatient-clinic practice by shift system at a hospital in Taegu (대구지역 한 중소병원의 교대제 근무에 의한 외래진료에 관한 연구)

  • Song, Jung Hup;Kim, Jing Kyun;Ha, Young Ae;Yeh, Min Hae
    • Quality Improvement in Health Care
    • /
    • v.1 no.2
    • /
    • pp.44-59
    • /
    • 1994
  • Medical consumers(patients) want evening-clinic because of busy work. For patient's convenience and improving service, hospital should accept it. Considering payment system and patient's demand, personnel expenses, hospital can not accept. The practice of shift system to accept patient's demand and hospital's economic aspect was made. To analysis the effect of the system and probability to alternative to evening clinic this study was done. This study was composed of basal study, intervention, evaluation of effect. The basal study were composed of studying demand on evening clinic, the number of beds, doctors employee, the time table of practice and work, and the number of patients at arrival time. The intervention composed of changing of practice time, changing of working time by the number of patients at arrival time, increasing of employee. The evaluation of effect were composed of evaluating the number of patient at time, the effect of shift system, the comparison of the number of in and out patients and questionnairing the practice of shift system. In the practice time at 2 shift system First team works 7-15 hours and Second team 12-20 hours. there are no lunch and supper time. At 18-20 hours the number of patients were 25-30. The number of patient a depart were 6-7. The number of out-patient increase in 13% and inpatient increase in 10% before the system. Doctors(100%), employee(94.6%), and patients(86.4%) approved this system. The advantage of this system were utilization of surplus time, lengthen the practice time, even distribution of patients and shortening of waiting time, rapid treatment of emergent patients. The disadvantage of this system were shortage of manpower, not all depart practice, continuity of practice, no lunch and supper time, irregular rounding. At present because of small Demanding on evening clinic, this shift system was economical. To succeed this study more effectively all depart in hospital participate. But because of economical reason it is impossible for hospital to do it. If the government assist the economic loss that all depart participate in this system it is very helpful for hospital to succeed in implementing this system more early.

  • PDF