• Title/Summary/Keyword: 단층선

Search Result 454, Processing Time 0.024 seconds

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

Case study on the lake-land combined seismic survey for underground LPG storage construction (LPG 지하저장기지 건설을 위한 수륙혼합 탄성파탐사 사례)

  • Cha Seong-Soo;Park Keun-Pil;Lee Ho-Young;Lee Hee-Il;Kim Ho-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.101-125
    • /
    • 2002
  • A lake seismic survey was carried out to investigate possible geohazards for construction of the underground LPG storage at Namyang Lake. The proposed survey site has a land-lake combined geography and furthermore water depth of the lake is shallow. Therefore, various seismic methods such as marine single channel high resolution seismic reflection survey, sonobuoy refraction survey, land refraction survey and land-lake combined refraction survey were applied. Total survey amounts are 34 line-km of high resolution lake seismic survey, 14 lines of sonobuoy refraction survey, 890 m of land refraction survey and 8 lines of land-lake combined refraction survey. During the reflection survey, there were severe water reverberations from the lake bottom obscured subsurface profiling. These strong multiple events appeared in most of the survey area except the northern and southern area near the embankment where seems to be accumulated mainly mud dominated depositions. The sonobuoy refraction profiles also showed the same Phenomena as those of reflection survey. Meanwhile the results of the land-lake combined refraction survey showed relatively better qualities. However, the land refraction survey did not so due to low velocity soil layer and electrical noise. Summarized results from the lake seismic survey are that acoustic basement with relatively flat pattern appeared 30m below water level and showed three types of bedrock such as fresh, moderately weathered and weathered type. According to the results of the combined refraction survey, a velocity distribution pattern of the lake bottom shows three types of seismic velocity zone such as >4.5 km/s, 4.5-4.0km/s and <4.0km/s. The major fault lineament in the area showed NW-SE trend which was different from the Landsat image interpretation. A drilling was confirmed estimated faults by seismic survey.

  • PDF

Solid Waste Disposal Site Selection in Rural Area: Youngyang-Gun, Kyungpook (농촌지역 쓰레기 매립장 입지선정에 관한 연구 -경상북도 영양군을 사례로-)

  • Park, Soon-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.1
    • /
    • pp.63-80
    • /
    • 1997
  • This study attempts to establish the criteria of site selection for establishing solid waste disposal facility, to determine optimal solid waste disposal sites with the criteria, and to examine the suitability of the selected sites. The Multi-Criteria Evaluation(MCE) module in Idrisi is used to determine optimal sites for solid waste disposal. The MCE combines the information from several criteria in interval and/or ratio scale to form a single index of evaluation without leveling down the data scale into ordinal scale. The summary of this study is as follows: First, the considerable criteria are selected through reviewing the literature and the availability of data: namely, percent of slope, fault lines, bedrock characteristics, major residential areas, reservoirs of water supply, rivers, inundated area, roads, and tourist resorts. Second, the criteria maps of nine factors have been developed. Each factor map is standardized and multiplies by its weight, and then the results are summed. After all of the factors have been incorporated, the resulting suitability map is multiplied by each of the constraint in turn to "zero out" unsuitable area. The unsuitable areas are discovered in urban district and its adjacencies, and mountain region as well as river, roads, resort area and their adjacency districts. Third, the potential sites for establishing waste disposal facilities are twenty five districts in Youngyang-gun. Five districts are located in Subi-myun Sinam-ri, nine districts in Chunggi-myun Haehwa-ri and Moojin-ri, and eleven districts in Sukbo-myun Posan-ri. The first highest score of suitability for waste disposal sites is shown at number eleven district in Chunggi-myun Moojin-ri and the second highest one is discovered at number twenty one district in Sukbo-myun Posan-ri that is followed by number nine district in Chunggi-myun Haehwa-ri, number seventeen and twenty three in Sukbo-myun Posan-ri, and number two in Subi-myun Sinam-ri. The first lowest score is found in number six district in Chunggi-myun Haehwa-ri, and the second lowest one is number five district in Subi-myun Sinam-ri. Finally, the Geographic Information System (GIS) helps to select optimal sites with more objectively and to minimize conflict in the determination of waste disposal sites. It is important to present several potential sites with objective criteria for establishing waste disposal facilities and to discover characteristics of each potential site as a result of that final sites of waste disposal are determined through considering thought of residents. This study has a limitation of criteria as a result of the restriction of availability of data such as underground water, soil texture and mineralogy, and thought of residents. To improve selection of optimal sites for a waste disposal facility, more wide rage of spatial and non-spatial data base should be constructed.

  • PDF

Clinical Analysis of Primary Malignant Lymphoma of the Lung (원발성 폐림프종의 임상 고찰)

  • Kim, Jae-Bum;Park, Nam-Hee;Kum, Dong-Yoon;Noh, Dong-Sub;Lee, Jae-Hoon;Han, Seung-Bum;Jung, Hye-Ra;Park, Chang-Kwon
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.435-440
    • /
    • 2007
  • Background: Primary malignant lymphoma of the lung is a very rare neoplasm. Although the prognosis of lymphoma is favorable, the clinical features, prognostic factors and management have not been clearly defined. Material and Method: We retrospectively reviewed the records of 8 patients we managed between 1994 and 2000. They all had malignant lymphoma on the pathologic examination of the lung wit no evidence of mediastinal adenopathy and extrathoracic disease, and no past history of lymphoma. Result: The study group consisted of 3 males and 5 female patients with a mean age of 53.9 years. Three patients were asymtomatic and 5 patients were seer with pulmonary or systemic symptoms. The diagnostic methods were 3 CT needle aspiration biopsies, 1 bronchoscopic biopsy and 4 surgical methods (wedge resection, lobectomy). There were 3 patients with MALT lymphoma, two with diffuse large B-cell lymphoma, two with small lymphocytic lymphom, and one with follicular lymphoma. The 8 patients were treated with a variety of modalities, including surgery, chemotherapy, radiotherapy and combination therapy. The 8 patients have survived for a median follow-up of 38 months. Conclusiian: Although this entity of lymphoma appears to have a good prognosis, further clinical experience and long-term follow-up are needed to identify its clinical features, prognostic factors and management.

EVALUATION OF CONDYLAR POSITION USING COMPUTED TOMOGRAPH FOLLOWING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY (전산화단층촬영법을 이용한 하악 전돌증 환자의 하악지 시상 골절단술후 하악과두 위치변화 분석)

  • Chol, Kang-Young;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.570-593
    • /
    • 1996
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after BSSRO in 20 patients(males 9, females 11) using computed tomogram that were taken in centric occlusion before, immediate, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period intermaxillary fixation, 24hour after removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.45{\pm}4.01mm$ and horizontal long axis of condylar angle was $11.89{\pm}5.19^{\circ}$on right, $11.65{\pm}2.09^{\circ}$on left side and condylar lateral poles were located about 12mm and medial poles about 7mm from reference line(AA') on the axial tomograph. Mean intercondylar distance was $84.43{\pm}3.96mm$ and vertical axis angle of condylar angle was $78.72{\pm}3.43^{\circ}$on right, $78.09{\pm}6.12^{\circ}$on left. 2. No statistical significance was found on the condylar change(T2C-T1C) but it had definitive increasing tendency. There was significant decreasing of the distance between both condylar pole and the AA'(p<0.05) during the long term(TLC-T2C). 3. On the lateral cephalogram, no statistical significance was found between immediate after surgery and 24 hours after the removing of intermaxillary fixation but only the lower incisor tip moved forward about 0.33mm(p<0.05). Considering individual relapse rate, mean relapse rate was 1.2% on L1, 5.0% on B, 2.0% on Pog, 9.1% on Gn, 10.3% on Me(p<0.05). 4. There was statistical significance on the influence of the mandibular set-back to the total mandibular relapse(p<0.05). 5. There was no statistical significance on the influence of the mandibular set-back(T2-T1) to the condylar change(T2C-T1C), the condylar change(T2C-T1C, TLC-T2C) to the mandibular total relapse, the pre-operative condylar position to the condylar change(T2C-T1C, TLC-T2C), the pre-operative mandibular posture to the condylar change(T2C-T1C, TLC-T2C)(p>0.05). 6. The result of multiple regression analysis on the influence of the pre-operative condylar position to the total mandibular relapse revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condyalr head long axis angle, the more increasing of mandibular horizontal relapse(L1,B,Pog,Gn,Me) on the right side condyle. The same result was founded in the case of horizontal relapse(L1,Me) on the left side condyle.(p<0.05). 7. The result of multiple regression analysis on the influence of the pre-operative condylar position to the pre-operative mandibular posture revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condylar head long axis angle, the more increasing of mandibular vertical length on the right side condyle. and increasing of vertical lengh & prognathism on the left side condyle(p<0.05). 8. The result of simple regression analysis on the influence of the pre-operative mandibular posture to the mandibular total relapse revealed that the more increasing of prognathism, the more increasing of mandibular total relapse in B and the more increasing of over-jet the more increasing of mandibular total relapse(p<0.05). Consequently, surgical mandibular repositioning was not significantly influenced to the change of condylar position with condylar reposition method.

  • PDF

Vessel Tracking Algorithm using Multiple Local Smooth Paths (지역적 다수의 경로를 이용한 혈관 추적 알고리즘)

  • Jeon, Byunghwan;Jang, Yeonggul;Han, Dongjin;Shim, Hackjoon;Park, Hyungbok;Chang, Hyuk-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.137-145
    • /
    • 2016
  • A novel tracking method is proposed to find coronary artery using high-order curve model in coronary CTA(Computed Tomography Angiography). The proposed method quickly generates numerous artificial trajectories represented by high-order curves, and each trajectory has its own cost. The only high-ranked trajectories, located in the target structure, are selected depending on their costs, and then an optimal curve as the centerline will be found. After tracking, each optimal curve segment is connected, where optimal curve segments share the same point, to a single curve and it is a piecewise smooth curve. We demonstrated the high-order curve is a proper model for classification of coronary artery. The experimental results on public data set sho that the proposed method is comparable at both accuracy and running time to the state-of-the-art methods.

Controlling the Work Functions of Graphene by Functionalizing the Surface of $SiO_2$ Substrates with Self-assembled Monolayers

  • Jo, Ju-Mi;Kim, Yu-Seok;Cha, Myeong-Jun;Lee, Su-Il;Jeong, Sang-Hui;Song, U-Seok;Kim, Seong-Hwan;Jeon, Seung-Han;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.400-401
    • /
    • 2012
  • 그래핀(Graphene)은 열 전도도가 높고 전자 이동도(200 000 cm2V-1s-1)가 우수한 전기적 특성을 가지고 있어 전계 효과 트랜지스터(Field effect transistor; FET), 유기 전자 소자(Organic electronic device)와 광전자 소자(Optoelectronic device) 같은 반도체 소자에 응용 가능하다. 그러나 에너지 밴드 갭이 없기 때문에 소자의 전기적 특성이 제한되는 단점이 있다. 최근에는 아크 방출(Arc discharge method), 화학적 기상 증착법(Chemical vapor deposition; CVD), 이온-조사법(Ion-irradiation) 등을 이용한 이종원자(Hetero atom)도핑과 화학적 처리를 이용한 기능화(Functionalization) 등의 방법으로 그래핀을 도핑 후 에너지 밴드 갭을 형성시키는 연구 결과들이 보고된 바 있다. 그러나 이러한 방법들은 표면이 균일하지 않고, 그래핀에 많은 결함들이 발생한다는 단점이 있다. 이러한 단점을 극복하기 위해 자가조립 단층막(Self-assembled monolayers; SAMs)을 이용하여 이산화규소(Silicon oxide; SiO2) 기판을 기능화한 후 그 위에 그래핀을 전사하면 그래핀의 일함수를 쉽게 조절하여 소자의 전기적 특성을 최적화할 수 있다. SAMs는 그래핀과 SiO2 사이에 부착된 매우 얇고 안정적인 층으로 사용된 물질의 특성에 따라 운반자 농도나 도핑 유형, 디락 점(Dirac point)으로부터의 페르미 에너지 준위(Fermi energy level)를 조절할 수 있다[1-3]. 본 연구에서는 SAMs한 기판을 이용하여 그래핀의 도핑 효과를 확인하였다. CVD를 이용하여 균일한 그래핀을 합성하였고, 기판을 3-Aminopropyltriethoxysilane (APTES)와 Borane-Ammonia(Borazane)을 이용하여 각각 아민 기(Amine group; -NH2)와 보론 나이트라이드(Boron Nitride; BN)로 기능화한 후, 그 위에 합성한 그래핀을 전사하였다. 기판 위에 NH2와 BN이 SAMs 형태로 존재하는 것을 접촉각 측정(Contact angle measurement)을 통해 확인하였고, 그 결과 NH2와 BN에 의해 그래핀에 도핑 효과가 나타난 것을 라만 분광법(Raman spectroscopy)과 X-선 광전자 분광법(X-ray photoelectron spectroscopy: XPS)을 이용하여 확인하였다. 본 연구 결과는 안정적이면서 패턴이 가능하기 때문에 그래핀을 기반으로 하는 반도체 소자에 적용 가능할 것이라 예상된다.

  • PDF