• Title/Summary/Keyword: 단층선

Search Result 454, Processing Time 0.039 seconds

Development of PET Detector Module Measuring DOI using Multiple Reflectors (여러 반사체를 사용한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Kim, Neung Gyun;Kim, Gu;Kwak, Jong Hyeok;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.825-830
    • /
    • 2019
  • A detector module measuring a depth of interaction was developed using silicon photomultiplier (SiPM) and two layers of scintillation crystal array treated with multiple reflectors. When reconstructing an image based on a signal obtained by using different types of reflector of each layer, the interaction positions of scintillation pixels and gamma rays could be tracked by utilizing the feature that all scintillation pixels were recorded at different positions. The bottom layer uses a specular reflector, and the top layer uses a diffuse reflector to differently process the size of the signal obtained from the SiPM. The optical grease was used to recude the sharp refractive index change between the layers of scintillator and the SiPM. The signals obtained from the 16 SiPMs were reduced to four signals using the Anger equations, and the images were reconstructed using them. All the scintillation pixels composed of the two layers appeared in the reconstructed image, which distinguished the layer where the scintillation pixels and gamma rays interacted. If the detectors, which measure the interaction depth of two layers using different reflectors, will be applied to preclinical positron emission tomography, the degradation of spatial resolution appearing outside the field of interest could be solved.

Study on Constituent Minerals and Illitization Characteristics of Yeongdong Illite Ore (영동 일라이트 광체의 구성광물 및 일라이트화 특성 연구)

  • EunJi Baek;Yu Na Lee;Byeongyong Yu;Dongbok Shin;Youngseuk Keehm;Sun Young Park;Hyun Na Kim
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.1
    • /
    • pp.41-54
    • /
    • 2023
  • Illite is a common mineral that forms readily from feldspar and mica via hydrothermal alteration and exhibits various characteristics depending on the degree of hydrothermal alteration. To ensure continued mining of high-quality illite ore, it is crucial to understand the illitization. Thus, this study collected ores from two illite ore deposit and their surrounding alteration zones in Yeongdong-gun, Chungcheongbuk-do, a significant source of illite in the Republic of Korea, to determine the constituent mineral contents and textural characteristics. Polarized light microscopy analyses revealed that the illite ore deposit were highly illitized with little remaining textural characteristics of the parent mica schist, and only some quartz was present. The ore zone contained illite, muscovite, quartz, and feldspar, with illitization primarily occurring around feldspar and quartz. X-ray diffraction analyses identified that the content of illite/muscovite was approximately 50-75 wt.%, with a maximum of 75 wt.%. Additionally, X-ray fluorescence analyses indicated a linear increase in K2O content with increasing illite content, showing the highest correlation among the major components analyzed. It is suggested that the illite in the Yeongdong area results from feldspar and quartz alteration by hydrothermal fluids along the fault, with illitization of feldspar occurring before that of quartz. The results of this study are expected to contribute to the development of high-quality illite ore deposit in Yeongdong, Chungcheongbuk-do.

A Case of Canine Uterine Adenocarcinoma with Negative Estrogen and Progesterone Receptor Expression (개의 에스트로겐과 프로케스테론 수용체 발현이 되지 않은 자궁 선암종 증례)

  • Cho, Hyang-Mi;Kim, Hyun-Wook;Kim, Hye-Jin;Choi, Ji-Hye;Jang, Jae-Young;Choi, Ul-Soo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.303-306
    • /
    • 2011
  • A 12-year-old female mixed breed dog receiving a progesterone drug was referred for evaluation of an abdominal mass. Abdominal radiography and ultrasonography revealed a swollen uterus and an associated mass. Serum chemistry revealed hyperglobulinemia consistent with acute inflammation based on the results of serum protein electrophoresis. Fine needle aspiration of the mass guided by ultrasonography was performed for cytological evaluation. The cytological impression was consistent with adenocarcinoma. Exploratory laparotomy identified a uterine body mass, which was surgically removed for histopathology. Histology of the mass identified a uterine adenocarcinoma. Immunochemistry using anti-estrogen and progesterone receptor antibodies was performed and neoplastic cells were negative to both antibodies while some normal elements were reactive to both of them. Computer tomography demonstrated evidence of metastatic disease in the lung one week after the surgery and the dog died about 40 days after surgery.

A Surface Reconstruction Method from Contours Based on Dividing Virtual Belt (가상벨트 분할에 기반한 등고선으로부터의 표면재구성 방법)

  • Choi, Young-Kyu;Lee, Seung-Ha
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.413-422
    • /
    • 2007
  • This paper addresses a new technique for constructing surface model from a set of wire-frame contours. The most difficult problem of this technique, called contour triangulation, arises when there are many branches on the surface, and causes lots of ambiguities in surface definition process. In this paper, the branching problem is reduced as the surface reconstruction from a set of virtual belts and virtual canyons. To tile the virtual belts, a divide-and-conquer strategy based tiling technique, called the BPA algorithm, is adopted. The virtual canyons are covered naturally by an iterative convex removal algorithm with addition of a center vertex for each branching surface. Compared with most of the previous works reducing the multiple branching problem into a set of tiling problems between contours, our method can handle the problem more easily by transforming it into more simple topology, the virtual belt and the virtual canyon. Furthermore, the proposed method does not involve any set of complicated criteria, and provides a simple and robust algorithm for surface triangulation. The result shows that our method works well even though there are many complicated branches in the object.

Usefulness of Chest High-Resolution CT in Patients with Chronic Cough Below 2 Years of Age (2세 미만의 만성 기침 환아에서 흉부 고해상 전산화 단층 촬영의 유용성)

  • Kim, Myung Hyun;Kim, Jung Hee;Lim, Dae Hyun;Son, Byong Kwan;Lee, Kyung-Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.3
    • /
    • pp.339-345
    • /
    • 2002
  • Purpose : The purpose of this study was to evaluate the clinical usefulness of chest high-resolution computed tomography(HRCT) in patients with chronic coughs or persistent wheezing with normal chest X-ray finding. Methods : We reviewed the charts, chest X-rays, and HRCT findings of patients with chronic coughs or persistent wheezing of less than 2 years of age. The records were sourced from the Department of Pediatrics, Inha University Hospital covering the period from July, 1999 to June, 2000. Chronic cough was defined as a cough which was prolonged for more than 3 weeks. Results : The sample consisted of 24 patients(male 15 and female 9, mean age $4.7{\pm}3.8$ months old). Among them, 16 patients showed normal findings(66.7%) and 8 patients showed abnormal (33.3%) in simple chest X-rays. Among 16 patients who had the normal chest X-rays, 13 patients showed abnormal chest HRCT findings(81.3%) such as air space consolidation of the dependent portion(62.5%), bronchiolitis obliterans(12.5%), and bronchopulmonary dysplasia(6.3%). Conclusion : We suggest that the chest HRCT is a useful diagnostic tool in the evaluation of patients with chronic cough or persistent wheezing with normal chest X-ray, especially below 2 years of age.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Geophysical Studies on Major Faults in the Gyeonggi Massif : Gravity and Electrical Surveys In the Gongju Basin (경기육괴내 주요 단층대의 지구물리학적 연구: 공주분지의 중력 및 지전기 탐사)

  • Kwon Byung-Doo;Jung Gyung-Ja;Baag Chang-Eob
    • The Korean Journal of Petroleum Geology
    • /
    • v.2 no.2 s.3
    • /
    • pp.43-50
    • /
    • 1994
  • The geologic structure of Gongju Basin, which is a Cretaceous sedimentary basin located on the boundary of Gyeonggi Massif and Ogcheon Belt, is modeled by using gravity data and interpreted in relation with basin forming tectonism. The electrical survey with dipole-dipole array was also conducted to uncover the development of fractures in the two fault zones which form the boundaries of the basin. In the process of gravity data reduction, the terrain correction was performed by using the conic prism model, which showed better results specially for topography having a steep slope. The gravity model of the geologic structure of Gongju basin is obtained by forward modeling based on the surface geology and density inversion. It reveals that the width of the basin at its central part is about $4{\cal}km$ and about $2.5{\cal}km$ at the southern part. The depth of crystalline basement beneath sedimentary rocks of the basin is about $700{\~}400{\cal}m$ below the sea level and it is thinner in the center than in margin. The fault of the southeastern boundary appears more clearly than that of the northwestern boundary, and its fracture zone may extended to the depth of more than $1{\cal}km$. Therefore, it is thought that the tectonic movement along the fault in the southeastern boundary was much stronger. These results coincide with the appearance of broad low resistivity anomaly at the southeastern boundary of the basin in the resistivity section. The fracture zones having low density are also recognized inside the basin from the gravity model. The swelling feature of basement and the fractures in sedimentary rocks of the basin suggest that the compressional tectonic stress had also involved after the deposition of the Cretaceous sediments.

  • PDF

Geological Structures of the Taean Formation in the Gomseom Area, Southwestern Gyeonggi Massif (경기육괴 남서부 곰섬 일대 태안층의 지질구조)

  • Kim, Inho;Kim, Ae-Ji;Woo, Hayoung;Park, Seung-Ik
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.159-168
    • /
    • 2019
  • The western Gyeonggi Massif, where records evidence of Phanerozoic subduction/collision tectonics, is an important area to understand the crustal evolutionary history of the Korean Peninsula. This study presents geometric and kinematic characteristics of the geological structures of the Taean Formation in the Gomseom area, southwestern Gyeonggi Massif. We interpreted the geometric relationships between structural elements, and conducted stereographic and down-plunge projections for structural domains. As a result, at least three different deformational events ($D_1$, $D_2$ and $D_3$) are recognized in the study area. In the first deformational event ($D_1$), regional foliations being well defined by the preferred orientation of muscovite and biotite were formed. In the second deformational event ($D_2$), NNE-trending low-angle contractional faults and related crenulation lineations/cleavages were formed. The crenulation lineations shallowly plunge toward SSW~SSE or NNW~NNE. In the third deformational event ($D_3$), SE-plunging folds and NE-trending high-angle faults were formed as 'fault-related fold' and 'fold-accommodation fault', indicating that the $D_3$ folds and faults are genetically linked to each other. This contribution provides important insights into the structural evolution of the Taean Formation along western Gyeonggi Massif, where had evolved as subduction/collisional orogenic belts in the East Asia.

Chest CT findings and Clinical features in Mediastinal Tuberculous Lymphadenitis (종격동 결핵성 임파선염의 흉부전산화 단층촬영 소견과 임상 양상에 대한고찰)

  • Lee, Young-Sil;Kim, Kyeong-Ho;Kim, Chang-Sun;Cho, Dong-Ill;Rhu, Nam-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Background: Recently there has been a trend of an increasing incidence of mediastinal tuberculous lymphadenitis(MTL) in adults. MTL often cause bronchial stenosis or esophago-mediastinal fistula. In spite of effective treatment, it is difficult to cure. Moreover, relapse frequently occurs. Authors analyzed chest CT findings and clinical features of 29 cases with MTL Methods: 29 cases with MTL were retrospectively studied with the clinical and radiologic features from April 1990 to March 1995 Results: 1) A total of 29 cases were studied. 12 cases were male and 17 cases were female. The male to female ratio was 1:1.4 Mean age was 29 years old. The 3rd decade(45%) was the most prevalent age group 2) The most common presenting symptoms and signs were palpable neck masses(62%) followed by cough(59%) and sputum(38%) 3) Except in one case of MTL, all patients had coexisting pulmonary tuberculosis, cervical tuberculous lymphadenitis, endobronchial tuberculosis and tuberculous pleurisy. Among the coexisting tuberculous diseases, Pulmonary tuberculosis was the most common(76%) 4) On simple chest X-ray, mediastinal enlargement was noted in 21 cases(72%), but it was not noted in 8 cases(28%). The most frequently involving site was the paratracheal node in 16 cases(72%). Rt side predominence(73%) was noted 5) Patterns of node appearance on a postcontrast CT scan were classified into 3 types. There were 19 cases(30%) of the Homogenous type, 30 cases(47%) of the Central low density type and 15 cases(23%) of the Peripheral fat obliteration type. The most common type was the central low density type. The most common lymph node size was 1~2 cm(88%) 6) The most frequently involved site was the paratracheal node in 26 cases(89%) by chest CT. Rt side(63%) was predominant 7) 9 cases(43%) had complete therapy and most common treatment duration was 13 - 18 months. 12 cases(57%) had incomplete continuing antituberculous medication and half of the cases had been treated above 19 months. Conclusion: Chest CT findings of MTL showed central low density area and peripheral rim enhancement, so this characteristic findings could differentiate it from other mediastinal diseases and help a diagnosis of tuberculosis. In spite of effective antituberculous medication, it is difficult to cure. Moreover, relapse frequently occurs. Further studies will be needed of the clinical features and the treatment of MTL.

  • PDF

Pulmonary Paragonimiasis Misdiagnosed with Pulmonary Tuberculosis (객혈과 공동 폐병변으로 폐결핵으로 오인된 폐흡충증 1예)

  • Park, Su Eun;Song, Bokyung;Hwang, Jae-Yeon
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.3
    • /
    • pp.178-182
    • /
    • 2017
  • Paragonimiasis was one of the most common causes of cavitary lung lesions until the 1960s, but now it has become a very rare disease in Korea. A 16-year-old boy presented with hemoptysis and several days of cough. His plain chest radiograph showed nodular opacity with a cavity in the left upper lung region. Although his symptoms disappeared after taking antituberculous drugs, his plain chest radiograph and computed tomography images after completion of therapy showed a new nodule with a cavity in the left lung field. Through video-assisted thoracoscopic wedge resection, Paragonimus eggs were found in the lung tissues.