• Title/Summary/Keyword: 단층선

Search Result 454, Processing Time 0.027 seconds

Cenozoic Geological Structures and Tectonic Evolution of the Southern Ulleung Basin, East Sea(Sea of Japan) (동해 울릉분지 남부해역의 신생대 지질구조 및 지구조 진화)

  • Choi Dong-Lim;Oh Jae-Kyung;Mikio SATOH
    • The Korean Journal of Petroleum Geology
    • /
    • v.2 no.2 s.3
    • /
    • pp.59-70
    • /
    • 1994
  • The Cenozoic geological structures and the tectonic evolution of the southern Ulleung Basin were studied with seismic profiles and exploration well data. Basement structure of the Korea Strait is distinctly characterized by normal faults trending northeast to southwest. The normal faults of the basement are most likely related to the initial liking and extensional tectonics of Ulleung Basin. Tsushima fault along the west coast of Tsushima islands runs northeastward to the central Ulleung Basin. The Middle Miocene and older sequences in the Tsushima Strait show folds and faults mostly trending northeast to southwest. These folds and faults may be interpreted as a result of compressional tectonics. The Late Miocene to Qauternary sequences are not much deformed, but numerous faults mostly N-S trending are dominated in the Tsushima Strait. The Ulleung Basin was in intial rifting during Oligocene, and then active extension and subsidence from Early to early Middle Miocene. Therefore SW Japan separated from Korea Peninsula and drifted toward southeast, and Ulleung Basin was formed as a pull-apart basin under dextral transtensional tectonic regime. During rifting and extensional stage, Tsushima fault as a main tectonic line separating SW Japan block from the Korean Peninsula acted as a normal faulting with right-lateral strike-slip motion as SW Japan drifted southeastward. During middle Middle Miocene to early Late Miocene, the opening of Ulleung basin stopped and uplifted due to compressional tectonics. The southwest Japan block converging on the Korean Peninsula caused compressional stress to the southern margin of Ulleung Basin, resulting in strong deformation under sinistral transpressional tectonic regime. Tsushima fault acted as thrust fault with left-lateral strike-slip motion. From middle Late Miocene to Quaternary, the southern margin of Ulleung Basin has been controlled by compressional motion. Thus the Tsushima fault still appears to be an active thrust fault by compressional tectonic regime.

  • PDF

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

The Automatic Detection of Inner Boundary on EBCT Images for Airway (기도에 대한 EBCT 영상에서의 내벽 윤곽선 자동검출)

  • 김명남;조진호
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.6
    • /
    • pp.991-999
    • /
    • 2003
  • In this paper, we proposed image acquisition techniques that can reflect anatomical airway information lot breath change by EBCT Also, we proposed new method to detect automatically boundary of inner airway for acquired slice images using this image acquisition technology. We confirmed that new method detects boundary of inner airway effectively through computer simulation that apply image data about each slice position of airway. And, we could see change for cross section area of inner airway by time change. Therefore, we think that proposed method can utilize on quantitative analysis in clinical field.

  • PDF

Evaluating Properties for Bi-layer PZT thin film Fabricated by RF-Magnetron Sputtering System (RF-마그네트론 스퍼터링법으로 제작한 이층형 PZT의 특성평가)

  • Lim, Sil-Mook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.222-227
    • /
    • 2020
  • Pb(Zr,Ti)O3(denoted as PZT) in the perovskite phase is used as a dielectric, piezoelectric, and super appetizer material owing to its ferroelectric properties. A PZT film was formed by an RF magnetron sputtering process by preparing a target composed of Pb1.3(Zr0.52Ti0.48)O3. The PZT film was formed by dividing the material into a mono-layer PZT produced continuously with the same sputtering power and a bi-layer PZT produced with two-stage sputtering power. The bi-layer PZT consisted of a lower layer produced under low-power sputtering conditions and an upper layer produced under the same conditions as the mono-layer PZT. XRD revealed small amounts of pyrochlore phase in the mono-layer PZT, but only the perovskite phase was detected in the bi-layer PZT. SEM and AFM revealed the upper part of the bi-layer PZT to be more compact and smooth. Moreover, the bi-layered PZT showed superior symmetry polarization and a significantly reduced leakage current of less than 1×10-5 A/cm2. This phenomenon observed in bi-layer PZT was attributed to the induction of growth into a pure perovskite phase by suppressing the formation of a pyrochlore phase in the upper PZT layer where the densely formed lower PZT layer was produced sequentially.

3D Fusion Imaging based on Spectral Computed Tomography Using K-edge Images (K-각 영상을 이용한 스펙트럼 전산화단층촬영 기반 3차원 융합진단영상화에 관한 연구)

  • Kim, Burnyoung;Lee, Seungwan;Yim, Dobin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.523-530
    • /
    • 2019
  • The purpose of this study was to obtain the K-edge images using a spectral CT system based on a photon-counting detector and implement the 3D fusion imaging using the conventional and spectral CT images. Also, we evaluated the clinical feasibility of the 3D fusion images though the quantitative analysis of image quality. A spectral CT system based on a CdTe photon-counting detector was used to obtain K-edge images. A pork phantom was manufactured with the six tubes including diluted iodine and gadolinium solutions. The K-edge images were obtained by the low-energy thresholds of 35 and 52 keV for iodine and gadolinium imaging with the X-ray spectrum, which was generated at a tube voltage of 100 kVp with a tube current of $500{\mu}A$. We implemented 3D fusion imaging by combining the iodine and gadolinium K-edge images with the conventional CT images. The results showed that the CNRs of the 3D fusion images were 6.76-14.9 times higher than those of the conventional CT images. Also, the 3D fusion images was able to provide the maps of target materials. Therefore, the technique proposed in this study can improve the quality of CT images and the diagnostic efficiency through the additional information of target materials.

A Study on the Difference of Scattered Rays with or Without Gonadal Shielding During Chest Computed Tomography (흉부 전산화 단층 촬영 검사 시 발생하는 생식선 차폐 유무에 따른 산란 선량 차이에 관한 연구)

  • Kwak, Jong Hyeok;Kim, Gyeong Rip;Sung, Hyun Chul;Kim, Seung Won;Song, Geun Sung;Choi, Min Gyeong;Lee, Sang Weon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2021
  • This study is a study on the difference in dose according to the presence or absence of gonadal shielding of scattered rays generated during chest computed tomography examination, and the scattered dose of the examination site was measured by placing the RadEye G-10 device in the center of the phantom. When the gonads are not shielded, the scattering lines of the whole, both sides, posterior and gonads are measured and Xenolite nolead Apron (0.35 mm PB), Xenolite nolead Apron (front 0.35 mm PB Mix back 0.25 mm PB, Skirt overlap), Half Apron After shielding with (0.5 mm PB), each scattered dose was measured. During chest computed tomography, the scattered dose of the test site was measured at 272 μSv, and when not shielded with Apron, the average total was 43 μSv, left 81 μSv, right part 82 μSv, posterior part 38.8 μSv, and Gonad part 16 μSv. Became. Xenolite nolead Apron shielded only the upper part and measured all 11.2 μSv, left part 43.1 μSv, right part 45.3 μSv, posterior part 12 μSv and Gonad part 5.2 μSv. Xenolite nolead Apron (Skirt overlap) covered the Pelvis area 360° and the dose was measured to be 5.6 μSv in the whole, 22.4 μSv in the left, 15.7 μSv in the right side, 6 μSv in the posterior part, and 3.2 μSv in the Gonad part. Xenolite nolead Apron (Skirt overlap) covered the Pelvis area 360° and the dose was measured to be 5.6 μSv in the whole, 22.4 μSv in the left, 15.7 μSv in the right side, 6 μSv in the posterior part, and 3.2 μSv in the Gonad part. When measuring only the upper part with Half Apron, the total measurement was 10.7 μSv, the left part 42.6 μSv, the right part 40.6 μSv, the posterior part 11.3 μSv, and the Gonad part 4.7 μSv. The method of 360° shielding of the pelvic area showed a dose reduction of more than 80%, and a dose reduction effect of more than 70% was shown when all shielding was performed. In all computerized tomography examinations, research to reduce the exposure dose and various shielding devices were used. It is believed that continuous research on the technique is needed.

Frture mapping and deep-seated ground water exploration in the crystalline rocks by integrated geophysical techniques (종합적 물리탐사에 의한 파쇄대 및 심부 지하수 탐사)

  • 정승환;김정호;조인기;전정수
    • The Journal of Engineering Geology
    • /
    • v.2 no.2
    • /
    • pp.113-130
    • /
    • 1992
  • Groundwater in crystalline basement is controlled primarily by tectonic fractures. It is evident that the delineation of the heavily faulted area and/or fractures deeply developped should be considerable value in deep-seated low enthalphy geothermal water. Electrical and electromagnetic methods have effectively been employed to map hydraulic faults and shear zones for groundwater exploration. In this study VLi; dipoledipole resistivity, controlled source audio~frequency magneto-telluric(CSAMT) and magnetic methods were applied in the Bomun resort area, adjacent to Kyongju city, southeastern part of Korea. The integrated geophysical tools employed in this experiment can be manifested themselves as: 1. Magnetic high for granite intrusions which is more favorable for geothermal gradient increase in depth. 2. VLF cross-over trends for mapping linear shallow conductive fractures and shear zones. 3. Dipole-dipole resistivity distributions for the deep-seated(less than 500m in depth) fractures and shear zones. The dipole-dipole resistivity field data were inverted to the true resistivity distribution with two-dimensional automatic inversion program based on the finite-difference method. 4. CSAMT provides an efficient way of delineating fractures and fault zones if the depth is greater than about 500m.

  • PDF

Development of an MCNP-Based Cone-Beam CT Simulator (MCNP 기반의 CBCT 전산모사 시스템 개발)

  • Lim, Chang-Hwy;Cho, Min-Kook;Han, Jong-Chul;Youn, Han-Bean;Yun, Seung-Man;Cheong, Min-Ho;Kim, Ho-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.351-359
    • /
    • 2009
  • We have developed a computer simulator fur cone-beam computed tomography (CBCT) based on the commercial Monte Carlo code, MCNP. All the functions to generate input files, run MCNP, convert output files to image data, reconstruct tomographs were realized in graphical user-interface form. The performance of the simulator was demonstrated by comparing with the experimental data. Although some discrepancies were observed due to the ignorance of the detailed physics in the simulation, such as scattered X-rays and noise in image sensors, the overall tendency was well agreed between the measured and simulated data. The developed simulator will be very useful for understanding the operation and the better design of CT systems.

Neuroblastoma : Computed Tomographic Finding (신경아세포종의 전산화단층촬영 소견)

  • Kim, Jae-Woon;Choi, Jong-Oh;Cho, Jae-Ho;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.134-140
    • /
    • 1996
  • Recently many studies have shown the usefulness of computed tomogram in diagnosing abdominal mass when clinical and conventional radiologic examinations fail to reveal the nature of abdominal mass or the cause of abdominal distension. To evaluate the usefulness of CT in diagnosing neuroblastoma, we retrospectively analyzed computed tomographic findings of 16 neuroblastoma patients, who pathologically proved in Yeungnam University Hospital from 1986 to 1995. The age range of the patients studied were from 8months to 18years. The most frequent sith of origin was adrenal gland and the next was retroperitioneum. The presenting symptoms were palpable mass, abdominal distension, and abdominal pain. The viewpoints of this analysis were turnoral calcifications, midline cross, shape, margin, internal structure, contrast enhancement patterns, major vessel involvement, and lymph node involvement. Characteristic CT findings were as follows: Fine dense curvillinear calcification within the tumor(56%), midline cross(50%), lobulation(75%), well-circumscribed margin(56%), cystic degeneration(56%), heterogeneous contrast enhancement(69%). encasement of major vessels such as aorta, IVC and celiac trunk(50%), and paraaortic lymphadenopathy(87%). We conclude that these CT findings were very common and could be helpful in diagnosting and differentiation neuroblastoma in infant and children.

  • PDF

First-principles Calculations on Magnetism of 1H/1T Boundary in Monolayer MoS2 (제일원리계산에 의한 단층 MoS2의 1H/1T 경계 자성)

  • Jekal, Soyoung;Hong, Soon Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.71-75
    • /
    • 2016
  • Monolayer $MoS_2$ is energetically most stable when it has a 1H phase, but 1H to 1T phase transition ($1H{\rightarrow}1T$) is easily realized by various ways. Even though magnetic moment is not observed during $1H{\rightarrow}1T$, $0.049{\mu}_B/MoS_2$ is obtained in local 1T phase; 75% 2H and 25% 1T phases are mixed in ($2{\times}2$) supercell. Most magnetic moment is originated from the 1T phase Mo atom in the supercell, while the magnetic moments of other atoms are negligible. As a result, magnetic/non-magnetic boundary is created in the monolayered $MoS_2$. Our result suggests that $MoS_2$ can be applied for spintronics such as a spin transistor.