• Title/Summary/Keyword: 단일 광경로

Search Result 22, Processing Time 0.018 seconds

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Electro-optic characteristics of novel biased vertical alignment device using the polymerized reactive mesogen (광경화성 단분자를 이용한 새로운 수직배향 액정 디바이스의 전기 광학적 특성연구)

  • Kim, Dae-Hyun;Kim, Sung-Min;Cho, In-Young;Kim, Woo-Il;Kwon, Dong-Won;Son, Jong-Ho;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.269-270
    • /
    • 2009
  • The biased vertical alignment (BVA) liquid crystal (LC) mode shows a has a distinct advantage of lower manufacture cost due to the elimination of a lithographic process step to form either ITO-patterning or protrusions on the color-filter substrates. However, those devices have complex voltage conditions which is the respective induce voltage on common electrode, pixel electrode and bias electrode when positive and negative frame. In order to overcome the complex voltage condition, the pretilt angles is controlled by photo polymerization of the UV-curable reactive mesogen (RM). According to our studies, voltages to the cell are critical to achieve an optimized surface-modified quality BVA (Q-BVA) mode which provides the well defined reorientation of the LCs with respect to an electric field.

  • PDF