• Title/Summary/Keyword: 단위시멘트량

Search Result 157, Processing Time 0.025 seconds

Measurement of Cement Content on Concrete Using the Method of Hydrochloric Acid Melting Heat (염산용해열법을 이용한 콘크리트의 단위시멘트량 추정)

  • Kim, Sang-Min;Sin, Se-Jun;Hyun, Seung Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.102-103
    • /
    • 2020
  • In this study, the effect of the change in the cement contents on the basic properties of the concrete and the estimation of the cement contents of hardened concretes using the hydrochloric acid melting heat. As a result of the study, as the cement contents increased, the fluidity and compressive strength increased, and there was no significant difference in the air contents and the unit volume mass. In addition, it showed a high correlation when compared with the estimated cement contents derived using the hydrochloric acid melting and the cement contents at the time of mixing. Therefore, it is considered that the hydrochloric acid melting is possible as a method of estimating the cement contents of concrete.

  • PDF

A Study of Concrete Mix Proportioning Design for Blast-furnace Slag Cement (슬래그시멘트의 콘크리트 배합설계 연구)

  • 김진춘;공양식;김동석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.215-220
    • /
    • 1994
  • 본 연구의 목적은 당사 콘크리트 배합설계 프로그램인 쌍용배합설계시스템(Ssangyong Mix Proportioning Design System ; 이하 SMPD라 칭한다)을 기본으로해서 슬래그시멘트에 대한 콘크리트 배합설계(안)을 제안함으로써 콘크리트 현장에서 합리적으로 콘크리트를 제조할 수 있도록 하는데 있다. 연구 내용은 슬래그시멘트와 보통시멘트간의 콘크리트 물성차이를 실험실적으로 규명하기 위해서 슬래그 함유량 및 양생 온도별로 슬래그시멘트의 콘크리트 강도발현특성, 물시멘트비, 단위수량변화 및 응결특성 등을 검토하였으며 그 결과를 이용하여 슬래그시멘트의 콘크리트 배합설계를 시행, 표준배합과 현장배합표를 제시하였다.

  • PDF

Mechanical Behavior and Characteristics of Internal Temperature and Relative Humidity of Concrete at Early Age (초기재령 콘크리트의 역학적 특성 및 온·습도 거동 특성 분석)

  • Park, Cheol Woo;Lee, Bong Hak;Hong, Seung Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.184-194
    • /
    • 2011
  • This study is to analyze the internal temperature and relative humidity of concrete at early age, as well as the mechanical behavior. Three different levels of cement unit content were cosidered as an experimental variable. In order to measure internal temperature and relative humidity immediately after concrete placement, this study developed a unique measuring device, which provided reliable results. Different cement content did not significantly affected the strengths including compressive, tensile and flexural strength and after 7 days of curing, strengths did not increase noticeably. Internal temperature reached the maximum about 11 hours later the placement and decreased after removal of forms. The internal temperature varied depending on the location and the exposure condition. In addition, the internal relative humidity was more affected by the exposure condition rather than the cement content.

An Experimental Study on the Evaluation of Adiabatic Temperature Rise of Concrete (콘크리트의 단열온도 상승량의 정량화에 관한 실험적 연구)

  • 강석화;이용호;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.186-196
    • /
    • 1995
  • In this study, parameters such as unit cement weight and placing temperature which influence on temperature rise and temperature rise velocity are investigated through adiabatic tests for the domestic ordinary portland cement(0PC). Adiabatic temperature rise suggested by Korean Concrete Spec. are compared with that from this experimental results. As a result of this study, adiabatic temperature rise of OPC suggested spec. is overestimated. Also it is shown that 2-parameter equation suggested in the spec. overestimate heat evolution at early age and reasonable prediction of heat evolution can be obtained by using 3-parameter equation. Results of numerical analysis by using the input data from this test and the suggested values from spec. shows similar temperatures. However thermal stresses pridicted using input value from spec. may result 20% more than that from this test in case of externally restricted state.

An Experimental Study on the Permeability Measurement and Development of Ultra Low Permeable Concrete (콘크리트의 투수성 측정 및 초저투수성 콘크리트의 개발 연구)

  • 오병환;정원기;차수원;장봉석
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.189-200
    • /
    • 1996
  • The permeability of concrete influences the durability of concrete remarkably. The conventional test method for permeability is very difficult to apply to high strength concrete because of its very low permeability. The present study employs a resonable and realistic test method for permeability of concrete and proposes a very low permeability concrete. To this end, comprehensive tests have been conducted and major test variables include the types and amount of cement. the types and amount of admixtures, and the size of aggregates. The present test results indicate t h a t the permeability decrease with the increase of strength and that the concrete with certain mineral admixtures exhibits very low permeability. The permeability of those high performance concrete is about 1/100 of conventional normal concrete. The present study provides a firm base for the use of very low permeable and hence very durable concrete.

Compressive Strength Development Properties of Concrete using Sodium based Accelerating Admixtures (나트륨계 기반 조강형 혼화제를 사용한 콘크리트의 압축강도발현 특성)

  • Song, Yeong-Chan;Lee, Tae-Gyu;Kim, Yong-Ro;Seo, Chi-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.259-266
    • /
    • 2018
  • In recent years, the early strength of concrete is important in order to shorten the time of form removal at the construction site. The purpose of this study is to analyze the moment of form removal as investigating the amount of cement contents and the physical properties and strength of the concrete according to types of admixture in the curing temperature of $10^{\circ}C$ for concrete of 21 to 27 MPa. As a result, it was found that compressive strength of concrete could not be secured 5 MPa by 36 hours even if the amount of cement contents were increased to $360kg/m^3$ with plain admixture. Also, it was confirmed that the strength improvement rate was excellent when using the accelerating agent with polycarboxylic acid type, and the moment of compressive strength of 5 MPa was estimated at 30 hours.

Grouting Effects of Microfine Cement in the Rock-based Sites (시멘트계 주입재료의 암반그라우팅 효과)

  • Kong, Jinyoung;Kim, Chanki;Park, Jinhwan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.37-45
    • /
    • 2010
  • The particle size of microfine cement(MC) is so small that it can be injected into silt layer. But the more particle size is miniaturized, the more the cohesion increases. This phenomenon results in the decrease of the perviousness of MC. In this study, the grouting effects of microfine cement with superplasticizer to maintain cohesion low and that of normal cement were investigated in rock. To estimate the grouting effects, TCR/RQD test for rock quality, lugeon test, borehole loading test for coefficients of elastic and deformative stress, borehole shear test for shear stress, detection p~q~t(pressure~flow~time) chart tests were carried out. The results using MC show a better permeability, modulus of elasticity, deformation, charge per unit, and recover efficiency of grouting material than those of ordinary portland cement except shear stress.

Evaluation on Mix Characteristics of Concrete Using Fine Sand of Nakdong-River (낙동강 세사를 사용한 콘크리트의 배합특성 평가)

  • Bae, Su-Ho;Kim, Chang-Duk;Lee, Seung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1481-1488
    • /
    • 2013
  • The purpose of this experimental research is to suggest a base data to utilize the fine sand of Nakdong-River actively as an alternative aggregate for concrete. For this purpose, after the typical fine sand samples were collected at the mid stream and down stream of main stream of Nakdong-River, the physical properties of them and the mix characteristics of concrete using those were estimated. As a result, it was observed from the test result that mix characteristics between concrete using fine sand and concrete using well-graded reference sand made little differences since unit water content and unit cement content of concrete using fine sand increased only a little than those of concrete using reference sand for specified compressive strength.

Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance (고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향)

  • 김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 1992
  • It is generally known that the frost-resistance of concrete is much affected by the air content in concrete and by the air void system or air distribution. And also the frost-resistance is believed to vary with the stre¬ngth of concrete. This article is prepared to describe, based on experiment, the effect of the air content and the air void system, particularly the effect of the spacing factor, on the freeze-thaw resistance of the high strength conc¬rete. For this purpose, I first worked on Non-AE concrete to make its compressive strength set about 400 to 500 kg/em'. However, the freeze-thaw test on the Non-AE concrete resulted in low durability factor, I.e., 10-2~0%. Thus to enhance the durability, another supplementary step was needed. I used AE admixture. which enhanced durability by changing the air content from 2% to 12%. The frost-thaw test was then performed 500 cycles on the 20 kind of concrete mixtures which differ in unit cement content and in water-cement ratio. Keywords : frost -resistance, air content, air void system, air distribution, spacing factor, freeze-thaw test, dur ability factor. capillary cavity, Linear Traverse Method.