• Title/Summary/Keyword: 단열 시트

Search Result 43, Processing Time 0.033 seconds

Thermal Insulation Performance of Composite Waterproofing Method of Thermal Supplement Type (단열 보완형 복합방수공법의 단열성능에 관한 연구)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 2014
  • Insulation of rooftop is one of the major performance to energy-saving construction. Further, waterproofing performance is also important. For such a reason, it is need to develop waterproofing method containing thermal insulation property. This study was wanted to evaluate thermal insulation performance about the composite waterproofing method of thermal supplement type that is developed recently. As a result of waterproofing performance test, every test item was showed over the performance standards of KS (Korean (Industrial) Standards). And the result of thermal insulation performance test, the highest temperature in the styrofoam box was $25.91^{\circ}C$, the bubble sheet box was $17.28^{\circ}C$, the insulation sheet box was $15.47^{\circ}C$ and the waterproofing sheet box of thermal supplement type was $24.11^{\circ}C$. In observations of thermal bridges of sheet's joint, thermal bridges was not identified at the sheet's joint. As a result, composite waterproofing method of thermal supplement type is interpreted to have thermal insulation performance.

Experimental Study on Properties of Temperature History Using Heating Sheet and Insulation Form at Low Temperature (발열시트 및 단열재를 사용한 거푸집 내부 콘크리트의 저온환경하 온도이력 특성에 관한 실험적 연구)

  • Choi, Si-Hyun;Lee, Han-Seung;Choi, Hyun-Kuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.132-139
    • /
    • 2017
  • In this study, in order to prevent the frost damage of the concrete, the characteristics of the form using heating sheet utilizing the chemical reaction of quicklime and the insulation were evaluated through experiments at low temperature. In the case of form at $-10^{\circ}C$, the form with attached heating sheet showed a temperature history of more than $10^{\circ}C$ higher than that of wood form at the early of concreting due to heat of the quicklime in the heating sheet. In the case of the insulated form, the concrete was kept at a high temperature by preserving the hydration heat. When the heating sheet and the isopink(extruded polystyrene) were attached together on the form, the effect was the same as that of the vacuum insulation. The compressive strength of the form with vacuum insulation and form with isopink, heating sheet as measured about 5 MPa at age 3. The experimental in Mongolia, as with the pervious results, the form with the heating sheet and the insulation showed the highest temperature history over $25^{\circ}C$ for 48 hours. Therefore, it was confirmed that the heating sheet and insulation are attached to the form, which helps the concrete strength development at low temperature by heat generation and the insulation effect.

Temperature History of the Concrete Corresponding to Various Curing Sheets in the Low Temperature (저온환경에서의 양생시트 변화에 따른 콘크리트의 온도이력 특성)

  • Baek, Dae-Hyun;Hong, Seak-Min;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.781-784
    • /
    • 2008
  • In this paper, insulating effect and strength development of concrete under low temperature are reported varying curing sheets. According to test results, in temperature -5$^{\circ}$C concrete subject to exposure and air cap condition, result in a frost damage at early age by a fall of below zero temperature. Mean while, the combination of PE film and non-woven fabric maintained around 3 $^{\circ}$C within first 24 hours since placement. For double bubble sheets, concrete temperature maintained above 7$^{\circ}$C due to its excellent heat insulating capability. As a result of core strength test, strength of specimens cured with viny + non-woven fabric and double bubble sheets had higher strength than strength of other specimens due to good heat insulation effect at early age.

  • PDF

Effect of Water Presence in Double Layer Bubble Sheet on Heat Insulation Capability in Cold Weather (이중버블시트의 함수상태가 단열보온 효과에 미치는 영향에 대한 특성분석)

  • Baek, Dae-Hyun;Hong, Seak-Min;Son, Ho-Jung;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.445-446
    • /
    • 2010
  • Water existed inside of bubble sheet applied at the job site sometimes results in undesirable heat insulation capability of bubble sheet. Therefore, the objective of this paper is to examine experimentally the effect of water presence in bubble sheet on heat insulation capability and strength of the concrete cured with double bubble sheet.

  • PDF

Application of Insulation Curing Method with Double Bubble Sheets Subjected to Cold Weather (이중 버블시트를 이용한 단열양생공법의 한중시공 적용 사례)

  • Hong, Seak-Min;Lee, Chung-Sub;Kim, Jong;Jeon, Chung-Kun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1001-1004
    • /
    • 2008
  • This study reviewed the results of utilization of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double layer bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and $10^{\circ}C$ even in case outside temperature drops $10^{\circ}C$ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than $6^{\circ}C$, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Performance of Heat Insulation Capability of the Concrete Applying Light Heat Generating Sheet (광발열 단열시트를 적용한콘크리트의 특성 )

  • Lee, Hyeon-Jik;Baek, Sung-Jin;Lee, Seung-Min;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.169-170
    • /
    • 2023
  • In this study, light-heat generating materials were produced in two ways, and the performance of two light-generating insulation sheets was reviewed. As a result of the experiment, it was possible to confirm the improved heating performance of the light heating insulation sheet compared to the existing bubble sheet. The light heat insulation sheet (b) showed improved thermal properties compared to the existing bubble sheet, and it is believed that the temperature has increased due to the combined effect of initial hydration heat and heat generation after installation. In future studies additional experiments are needed to compensate for the insufficient insulation performance due to the single bubble sheet through the double bubble sheet and to adjust the amount of light-generating materials added as a consideration of the optimal heat-generating effect of the light-generating insulation sheet (b).

  • PDF

Insulation Effect of Double Layered Bubble Sheet Application in Cold Weather Concrete and Initial Quality Control by Wireless Sensor Network (한중시공에서 2중 버블시트 포설에 따른 단열 효과분석 및 무선센서 네트워크에 의한 초기 품질관리)

  • Han, Min-Cheol;Seo, Hang-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2021
  • The objective of this study is to evaluate the effect of the application of double layered bubble sheet on the curing of slab and wall concrete placed at the job site in cold weather and to offer a feasibility of Concrete IoT Management System(CIMS), which is wireless sensor network developed by the authors, to manage early age quality of the concrete in terms of temperature, maturity and strength development. Test results indicated that the application of bubble sheet enhances the insulation performance, which results in an increase of the temperature by around 1~20. 6℃. It is found that CIMS can gather the temperature, maturity and strength development data from the sensors embedded from 30 m far from CIMS successfully. Predicted compressive strengths by CIMS had good agreement with measured ones within 2 MPa error level until 7 days. It is thought that the combination of the bubble sheet application for cold weather protection and CIMS for quality management tool in cold weather concreting contributes to shorten the time for the form removal by one day.

Analysis on the Heat Insulation Performance of Cold Weather Concrete according to Change of Laid Construction Conditions of Double Bubble Sheets (이중버블시트의 포설 시공조건 변화에 따른 한중 콘크리트의 단열보온 성능 분석)

  • Han, Cheon-Goo;Han, Min-Cheol;Baek, Dae-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.121-128
    • /
    • 2010
  • The present research examined heat insulation performance according to change of various laid construction conditions of double bubble sheet being used as material for heat insulation & curing construction of cold weather concrete, and its results are as follows. First, the change in a laid period of bubble sheet within 4 hours and the change in water content inside bubble sheet overall showed similar temperature history and maturity without a big difference in terms of the temperature history of concrete according to construction factors, but it could be confirmed that when a structure was thin or several bubble sheets are laid, requisites unfavorable for initial curing of concrete can occur if a lagger distance between sheets is generated. In terms of the compressive strength of concrete core specimens, it appeared that the initial compressive strength is declined when conditions unfavorable for concrete curing such as delay of a laid period of bubble sheets, induction of large distance between sheets, increase of water content inside bubble sheets and thinness of a structure of placing concrete, etc. were applied, but it appeared that as its age passes, the difference becomes small.

Finite Element Anmllysis of Adiabatic Shear Band (단열 전단 밴드의 유한요소 해석)

  • 유요한;전기영;정동택
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1519-1529
    • /
    • 1992
  • A stepped specimen which is subjected to step loading is modeled to study the initiation and growth of adiabatic shear band using explicit time integration finite element code. The material model for specimen includes effects of thermal softening, strain hardening and strain rate hardening. Various mesh sizes are tested to check whether they are small enough to model highly localized discontinuous phenomena reasonably well. It is shown that the number of adiabatic shear band depends on impact velocity and it is also shown that the initiation and growth of adiabatic shear band inversely depends on prescribed velocity at the top of specimen.