• Title/Summary/Keyword: 단열압축

Search Result 161, Processing Time 0.022 seconds

Development of Forms for Cold Weather Concrete by Combination of Insulation (단열재 조합에 의한 한중콘크리트용 거푸집 개발)

  • Han, Cheon-Goo;Oh, Seon-Kyo;Sin, Dong-An;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.392-399
    • /
    • 2003
  • This paper discusses the validities of insulating curing of cold weather concreting at early stage by applying insulation forms. Tests were carried out using modified insulating form combining existing insulating form and various other insulations in order to develop improved insulation form. Temperature history of concrete using various insulating forms and insulation was measured to determine most effective combination of insulting form. According to results, as for the wall form, under the curing temperature of $-10^{\circ}C$, the temperature of concrete using Euro form drops sharply before 24 hours and lasts below $0^{\circ}C$ for 7 hours. The temperature of concrete using the form combining Polypropylene panel, styrofoam and plywood panel keep above $0^{\circ}C$. And, it is confirmed that the form mentioned above has a favorable effects on enhancing strength development of concrete and the cost to make the forms shows more reasonable than that of existing forms. However, as for the combination methods of insulation form for slab, which is composed of insulating form at the bottom of slab and various surface curing materials at the top of slab, in case of exposed condition at the top of slab, temperature history of concrete goes below $0^{\circ}C$ after 10 hours. In case of the combination of vinyl sheet and curing blanket, it drops below $0^{\circ}C$ after 42 hours. However, in case of the combination of vinyl, styrofoam and curing blanket, it does not go below $0^{\circ}C$ until 55 hours. Accordingly, compared to the case of exposure and the combination of vinyl and curing blanket, it indicates that the combination mentioned above has more effective insulating performance.

Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor (정익 슈라우드 공기분사가 단단 천음속 축류압축기의 공력성능에 미치는 영향)

  • Dinh, Cong-Truong;Ma, Sang-Bum;Kim, Kwang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.9-19
    • /
    • 2017
  • In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

Effect of Concrete Containing the Biochar on Properties and Thermal Insulation Performance (바이오차를 혼입한 콘크리트의 물성 특성과 단열성능에 미치는 영향)

  • Kyoung-Chul, Kim;Kyung-Taek, Koh;Min-Su, Son;Gum-Sung, Ryu;Jae-Yoon, Kang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.428-434
    • /
    • 2022
  • This study intends to develop an eco-friendly concrete panel mixed with biochars. Experiments about mechanical and thermal properties were conducted on porous biochar concrete, which has insulation and carbon-capture performance. The concrete has a mixing ratio of 0, 5, 10, and 15 % for biochar and a water-binder ratio of 0.35. The unit weight, porosity, and permeability were measured to evaluate the mechanical characteristics. From the results, as the biochar mixing rate increased, the porosity and the permeability increased, but the unit weight decreased. Even though a decreased trend was observed in the compressive strength results, they satisfied the design standard. Since the thermal conductivity was decreased during the increase of contents, biochar could be considered an excellent material for insulation performance. In addition, regression analyses were conducted regarding the relationship of unit weight with porosity, compressive strength with thermal conductivity, and porous with thermal conductivity. From the regression, significant variables for expanding the scope of the application of biochar were presented.

Anatomical Comparison between Compression Wood and Opposite Wood in a Branch of Ginkgo biloba L. (은행나무 지재(枝材)의 압축이상재(壓縮異常材)와 대응재(對應材)에 관(關)한 해부학적(解剖學的) 특성(特性) 비교(比較))

  • Eom, Young-Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.77-85
    • /
    • 1991
  • 은행나무 지재(枝材)에 발달(發達)하여 있는 압축이상재(壓縮異常材)와 대응재(對應材)의 해부학적(解剖學的) 특성(特性) 차이(差異)를 조직(組織) 및 그 구성요소(構成要素)의 크기 면에서 서로 검토(檢討) 비교(比較)하였다. 조직적(組織的)인 특성(特性)으로는 압축이상재(壓縮異常材)가 연륜폭(年輪幅), 횡단면상(橫斷面上) 가도관(假導官) 형상(形狀) 및 방사조직(放射組織) 비례상태(比例狀態), 세포간극(細胞間隙), 가도관(假導官) 선단(先端)의 굴곡(屈曲), 나선열(螺旋裂) 및 접선단면상(接線斷面上)의 방사조직(放射組織) 형상(形狀) 면에서 대응재(對應材)와 차이(差異)를 나타냈으며 구성요소(構成要素)의 크기에 있어서는 가도관(假導官)의 벽후(壁厚) 및 접선직경(接線直徑), 단열(單列) 방사조직(放射組織)의 높이, 이열방사조직(二列放射組織)의 수(數) 및 방사조직(放射組織) 밀도(密度) 면에서 압축이상재(壓縮異常材)가 대응재(對應材)와 차이(差異)를 나타내는 것으로 여겨졌다.

  • PDF

Study on Adiabatic Performance of LNG Storage Tank for Vehicles (차량용 LNG연료용기의 단열성능에 관한 연구)

  • Han, Jeong-Ok;Lee, Young-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • Natural gas vehicles are being applied to city buses for improving air quality in metropolitan and have proved the effective way to reduce the pollutant emissions. Liquified Natural Gas(LNG) has also attempted a vehicle fuel in order to raise the fuel storage density that is a disadvantage of Compressed Natural Gas(CNG). This paper described insulation characteristic of a LNG storage tank. From the results, adiabatic coefficient of a tested tank was around $40J/h{\cdot}^{\circ}C{\cdot}m^2$ and it was the lower level than gas safety regulation limit. Two experimental methods were adopted to justify the evaluation results and they were revealed that the results were very similar to each other. Also, through testing relief valve operation characteristic it was investigated venting amount of boiled off gas.

  • PDF

Effect of Waste Glass Wool on Mechanical Properties of Concrete (폐글라스울이 콘크리트의 역학적 특성에 미치는 영향)

  • Kim, Jeong-Tae;Choi, Woo-Hyuk;Chung, Chul-Woo;Lee, Jae-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • Glass wool is a material that has been used as a heat insulator in various fields including construction industry. Since it is a nonflammable material, it does not generate toxic gases on fire, and thus public agencies recommend using glass wool as a heat insulator instead of other organic materials. However, repeated drying and wetting cycles can deteriorate thermal property of glass wool due to the shrinkage and reduction in pore size. For this reason, it needs to be replaced periodically, and waste materials are generated. This research aims to utilize waste glass wool as additives for increasing mechanical properties of concrete. According to the experimental results, it was found that glass wool has weak pozzolanic activity, and beneficial effect on both compressive and flexural strength. The optimum amount found in this experimental work was 0.5% volumetric addition to the concrete.

Insulation Effect of Double Layered Bubble Sheet Application in Cold Weather Concrete and Initial Quality Control by Wireless Sensor Network (한중시공에서 2중 버블시트 포설에 따른 단열 효과분석 및 무선센서 네트워크에 의한 초기 품질관리)

  • Han, Min-Cheol;Seo, Hang-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2021
  • The objective of this study is to evaluate the effect of the application of double layered bubble sheet on the curing of slab and wall concrete placed at the job site in cold weather and to offer a feasibility of Concrete IoT Management System(CIMS), which is wireless sensor network developed by the authors, to manage early age quality of the concrete in terms of temperature, maturity and strength development. Test results indicated that the application of bubble sheet enhances the insulation performance, which results in an increase of the temperature by around 1~20. 6℃. It is found that CIMS can gather the temperature, maturity and strength development data from the sensors embedded from 30 m far from CIMS successfully. Predicted compressive strengths by CIMS had good agreement with measured ones within 2 MPa error level until 7 days. It is thought that the combination of the bubble sheet application for cold weather protection and CIMS for quality management tool in cold weather concreting contributes to shorten the time for the form removal by one day.

Technical Papers : Performance Test of a Two Stage Axial Compressor of a Turboshaft Engine for Helicopters (기술논문 : 헬리콥터용 터보샤프트엔진 2 단 축류압축기 성능시험)

  • Kim, Chun-Taek;Kim, Jin-Han;Yang, Su-Seok;Lee, Dae-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.139-145
    • /
    • 2002
  • 이륙중량 4000kg, 10-12인승급 다목적 헬리콥터에 적용가능한 엔진 개량 개발을 목표로 기존 헬리콥터 엔진을 개량대상으로 선정하고 이러한 다목적 헬기의 요구조건에 부합하기 위해 기존 엔진의 요소부품을 재설계하였다. 첫 단계로 최소변경으로 720 hp에서 840 hp로 출력을 증강시키기 위하여 2단 축류압축기의 기존 입구 유도익을 제거하고 익현의 길이를 증가하여 유량 및 압축비를 증가시킴으로써 출력 증강을 얻도록 재설계를 수행하였다. 이러한 2단 축류압축기의 성능을 검증하기 위하여 두 번째 단 단독시험 및 전체 2단에 대한 성능시험이 수행되었으며 첫 번째 단의 성능은 이 결과로부터 도출되었다. 성능시험결과 전체 2단 압축기는 유량 3.088 kg/s에서 압력비 2.14, 단열효율 88%의 성능을 갖는 것으로 나타났으며 압축기 출구의 압력 및 온도 분포를 레이크를 이용하여 측정하였다.

A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (1) (수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (1))

  • Seo, Sung-Kwan;Chu, Yong-Sik;Lee, Jong-Kyu;Song, Hun;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.219-224
    • /
    • 2013
  • In this study, the inorganic insulating material was fabricated with quartzite, ordinary portland cement(OPC), lime and anhydrous gypsum. After characteristic analysis of slurry, the optimum mixing ratio was derived with different $CaO/SiO_2$ mole ratio. Based on derived mixing ratio, the inorganic insulating material was fabricated at different water content and hydrothermal synthesis conditions. Specific gravity was $0.26g/cm^3$, compressive strength was 0.4 MPa, and thermal conductivity was 0.064 W/mK. This properties were enhanced performance of conventional ALC (Autoclaved Lightweight Concrete). And it can replace organic insulation with harmless inorganic insulation through continues research and development.

Thermal Performance and Impact Resistance Evaluations of Composite Insulation Mat Reinforced Polyurethane Foam (복합 단열 매트 보강 폴리우레탄 폼의 열적 성능 및 내충격성 평가)

  • Hwang, Byeong-Kwan;Bae, Jin-Ho;Lee, Jae-Myung
    • Composites Research
    • /
    • v.32 no.5
    • /
    • pp.290-295
    • /
    • 2019
  • In the present study, composite insulation mat was reinforced over polyurethane foam (PUF) to improve the thermal performance and impact resistance of the PUF applied to the liquefied natural gas carrier insulation system. The composite insulation mat used Kevlar, aerogel, and cryogel composite mat that can be applied in a cryogenic environment. The thermal conductivity was measured at $20^{\circ}C$ to investigate the thermal performance, and the drop impact test was carried out under impact energy of 30 J at $20^{\circ}C$, $-163^{\circ}C$ to investigate the impact resistance. The measured thermal performance was compared with neat PUF through effective thermal conductivity theoretical value. The shock resistance was evaluated of contact force, contact time, and absorb energy. In experimental results, cryogel composite mat was the best performance in terms of thermal performance, and aerogel composite mat was the best performance in terms of impact resistance.