• Title/Summary/Keyword: 단안시

Search Result 7, Processing Time 0.024 seconds

Real-time Monocular Camera Pose Estimation using a Particle Filiter Intergrated with UKF (UKF와 연동된 입자필터를 이용한 실시간 단안시 카메라 추적 기법)

  • Seok-Han Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.315-324
    • /
    • 2023
  • In this paper, we propose a real-time pose estimation method for a monocular camera using a particle filter integrated with UKF (unscented Kalman filter). While conventional camera tracking techniques combine camera images with data from additional devices such as gyroscopes and accelerometers, the proposed method aims to use only two-dimensional visual information from the camera without additional sensors. This leads to a significant simplification in the hardware configuration. The proposed approach is based on a particle filter integrated with UKF. The pose of the camera is estimated using UKF, which is defined individually for each particle. Statistics regarding the camera state are derived from all particles of the particle filter, from which the real-time camera pose information is computed. The proposed method demonstrates robust tracking, even in the case of rapid camera shakes and severe scene occlusions. The experiments show that our method remains robust even when most of the feature points in the image are obscured. In addition, we verify that when the number of particles is 35, the processing time per frame is approximately 25ms, which confirms that there are no issues with real-time processing.

Ultrastructural Study of Drosophila Ocellar Visual System by Osmium Impregnation (오스뮴침착법에 의한 초파리 단안시각계의 미세구조)

  • Yoon, Chun-Sik
    • Applied Microscopy
    • /
    • v.29 no.4
    • /
    • pp.451-457
    • /
    • 1999
  • Ultrastructure of adult Drosophila ocellus was compared with conventional electron microscopic method and osmium impregnation. When osmium impregnation was applied, some organelles of cells were strongly stained. Especially, subrhabdomeric cisternae (SRC) were strongly stained and showed network-iike structure as in compound eye. Other organelles including SSC, ER, nuclear envelope, pigment granules and mitochondria were also strongly stained. These organelles are known as a general calcium ion reservoir. In conclusion, the strong effect of light and shade by osmium impregnation was regarded as a result of strong binding between calcium ion and osmium tetroxide. Thus, we agree to the opinion that osmium impregnation is very useful methods to the comparative morphology of cell organelles.

  • PDF

Biomimetic approach object detection sensors using multiple imaging (다중 영상을 이용한 생체모방형 물체 접근 감지 센서)

  • Choi, Myoung Hoon;Kim, Min;Jeong, Jae-Hoon;Park, Won-Hyeon;Lee, Dong Heon;Byun, Gi-Sik;Kim, Gwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.91-93
    • /
    • 2016
  • From the 2-D image extracting three-dimensional information as the latter is in the bilateral sibeop using two camera method and when using a monocular camera as a very important step generally as "stereo vision". There in today's CCTV and automatic object tracking system used in many medium much to know the site conditions or work developed more clearly by using a stereo camera that mimics the eyes of humans to maximize the efficiency of avoidance / control start and multiple jobs can do. Object tracking system of the existing 2D image will have but can not recognize the distance to the transition could not be recognized by the observer display using a parallax of a stereo image, and the object can be more effectively controlled.

  • PDF

Effects of visual information on Y-Balance Test (시각정보가 Y-Balance Test에 미치는 영향)

  • Byung-Hoon Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.977-987
    • /
    • 2023
  • The purpose of this study was to investigate the effect of visual information on the dynamic balance on Y-balance Test(YBT). The subjects of the study were 18 male and female adults in their 20s and 30s (age: 23.17±1.72 years, height: 172.46±9.84 cm, weight: 73.39±11.44 kg, leg length: 88.89±5.69 cm) who participated in the study. To measure dynamic balance between binocular and monocular use, absolute reach distance, composite score, and COP variables were measured on left and right feet through YBT and results were derived. As a result of the study, monocular block(left and right eye block) showed higher absolute reach and composite scores than binocular use in posterolateral, posteromedial, and composite scores during YBT. As a result of COP, there was no difference in anterior and posteromedial reach. When reaching posterolateral, AP COP velocity of left foot in monocular block appeared slower than that in binocular vision, and in COP velocity, COP velocity of left foot in monocular block appeared slower than binocular vision.

The Effects of Visual acuity increase in mono vision by the P-VEP study using Netspeg lens (Netspag Lens를 이용한 Mono vision에서 시력개선 효과에 대한 P-VEP 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.241-246
    • /
    • 2005
  • The aim of the study was performed the wave analysis of P-VEP on the development of visual function using Netspeg lens in monocular of refraction error subjects. The P-VEP of three channels were recorded by the Bausch Lomb system. Ten adults (five males, five females, mean=22 years, range=19 to 23) subjects were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, ocular disease, and so on. Visual acuity and refraction test were performed for each subject with mono vision by using the Netspeg lens. Also subjects viewed the P-VEP stimulus with mono vision through the corrected visual acuity with Netspeg lens during VEP test. The results of study suggest that the mono vision using Netspeg lens is better than with non-Netspeg lens on the visual acuity and image symptom. On the other hand, the analysis of P-VEP suggest that the amplitude of wave is larger when the eye using Netspeg lens receives the P-VEP stimulus compared with the non Netspeg lens. Also, on the wave style of P-VEP, the eye of Netspeg lens was more stable compared with the naked eye. However, on latency period of P-VEP, the eye of non Netspeg lens was more longer than the eye of Netspeg lens. But, on the other hand, the right and left eye have similar results. In conclusion, this study indicated that the visual acuity and visual function of eye of Netspeg lens used have a better than the eye of non-Netspeg lens in Mono Vision.

  • PDF

Effect of the Polaroid Lens in Binocular Vision (양안시에서 편광렌즈의 영향)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.135-151
    • /
    • 2003
  • This study compared the effect of Polaroid$^{(R)}$ lenses on binocular vision by assessing visual acuity, stereopsis, and visual evoked potential(VEP), through Polaroid$^{(R)}$, CR 39 and sunglass lenses. The spectral absorptions of Polaroid$^{(R)}$, CR 39 and sunglass lenses were measured using a spectrophotometer (Hitachi. U-3501). The VEP were recorded by the Nicolet system. Thirty normal adult(fifteen males, fifteen females, mean=21.9 years, range=20 to 25) subjects were recorded. The subjects were provided a history including : general health, family health, medication, genetics, allergy and disease. All had normal or corrected to normal acuity with no history of visual disorders. Corrected visual acuity, colour vision and stereopsis were recorded for each subject monocularly and binocularly. Each test was repealed through the sunglass, CR 39, and Polaroid$^{(R)}$ lenses. Subjects viewed the VEP stimulus both monocularly and binocularly through the test lenses while the VEPs were recorded. The results suggest that the binocular visual acuity and stereoacuity is better than with monocular vision. On other hand, the analysis of VEP suggests that the amplitude of wave is smaller when the monocular eye receives the VEP stimulus compared with that when the binocular eye is stimulated by the VEP target with the sunglass, CR 39, and Polaroid$^{(R)}$ lens. But, the latency period of each eye was similar to results between the dominant eye and the non-dominant eye by the CR 39, sunglass, and polaroid lens. In conclusion, this study indicates that the binocular vision appears to be better through the brown Polaroid$^{(R)}$ lens than through the other test lenses.

  • PDF

The Analysis of the P-VEP on the Normal Monocular Vision and Amblyopia in Binocular (앙안에서 정상 단안시와 약시안의 P-VEP 분석)

  • Kim, Douk-Hoon;Kim, Gyu-Su;Sung, A-Young;Park, Won-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • The aim of the study was performed the wave analysis of P-VEP on the normal monocular vision and amblyopia in binocular. The P-VEP of three channels were recorded by the Nicolet system. Five adults (three males, two females, mean=22 years, range=19 to 24) subjects were recorded The subjects were researched the history including the systemic health, medication, genetics, allergy and ocular disease. Visual acuity and stereopsis were recorded for each subject monocularly and binocularly. Also subjects viewed the P-VEP stimulus both monocularly and binocularly through the corrected visual acuity during the VEP were recorded. The results of study suggest that the visual acuity of binocularly is better than with monocularly and the stereopsis was about over 140 sec. On the other hand, the analysis of P-VEP suggest that the amplitude of wave is larger when the monocular eye receives the P-VEP stimulus compared with the binocular eye. However the amplitude of wave in amblyopia had more smaller than the normal monocular The latency period of P-VEP was similar to results between the normal eye and binocular vision. But the amblyopia was a long period compared with the normal monocular and binocular vision. In conclusion, this study indicated that the visual acuity of binocularly have a better than the normal monocular vision, But in the P-VEP test, the amplitude of wave on normal monocularly vision appears to be better through the binocularly. But the amblyopia appeared the low amplitude wave of P-VEP and decreased the visual acuity.

  • PDF