• Title/Summary/Keyword: 단상 유동

Search Result 55, Processing Time 0.025 seconds

Analysis on condensation heat transfer and pressure drop to develop design program for plate heat exchangers (판형열교환기 설계프로그램 개발을 위한 응축열전달 및 압력강하 분석)

  • Ko, Jea-Hyun;Song, Young-Ho;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.376-382
    • /
    • 2014
  • The purpose of this study is to get the formulas of condensation heat transfer coefficient and pressure drop about the water to develop design program for plate type heat exchangers. The single phase flow of cold side was calculated with the correlation of Ko. Condensation heat transfer coefficient model proposed by Annaiev was used and Lockhart model was used to analyze the pressure drop. The calculation algorithm was proposed to calculate heat transfer rate and pressure drop simultaneously. The prediction errors remained within 20% compared to the commercial code in the working range of the plate heat exchangers.

Numerical Investigation of Thermal Characteristics and Geometrical Optimization in circular tubes with micro fins (원형 단면관 내 미세 휜의 형상 변화에 따른 열.유동 특성 및 최적 형상 개발에 관한 수치 해석)

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1113-1118
    • /
    • 2006
  • A numerical investigation of single phase heat and flow characteristics in circular tubes with a single set of spiral micro fins was performed with varying geometrical parameters like fin height, spiral angle, and number of fins. The properties of $40^{\circ}C$ water was used as a working fluid to simulate a condenser and the RNG $k-{\epsilon}$ turbulence model was adopted. Calculation results were obtained in fully developed turbulent flow with constant surface heat flux boundary condition. Relative terms were introduced to investigate the substitution effect of conventional smooth tubes. The dimensionless terms were the heat transfer enhancement factor, the pressure drop penalty factor, and the efficiency index. Additionally, a numerical optimization was carried out to maximize thermal performance with the concept of the robust design. A statistical analysis showed that fin height interacts with number of fins and spiral angle.

  • PDF

Natural Convection in a Water Tank with a Heated Horizontal Plate Facing Downward (아래로 향한 수평가열판이 있는 수조에서의 자연대류)

  • Yang, Sun-Kyu;Chung, Moon-Ki;Helmut Hoffmann
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.301-316
    • /
    • 1995
  • experimental and computational studies ore carried out to investigate the natural convection of the single phase flow in a tank with a heated horizontal plate facing downward. This is a simplified model for investigations of the influence of a core melt at the bottom of a reactor vessel on the thermal hydraulic behavior in a oater filled cavity surrounding the vessel. In this case the vessel is simulated by a hexahedron insulated box with a heated plate Horizontally mounted at the bottom of the box. The box with the heated plate is installed in a water filled hexahedron tank. Coolers are immersed in the U-type water volume between the box and the tank. Although the multicomponent flows exist more probably below the heated plate in reality, present study concentrates on the single phase flow in a first step prior to investigating the complicated multicomponent thermal hydraulic phenomena. In the present study, in order to get a better understanding for the natural convection characteristics below the heated plate, the velocity and temperature are measured by LDA(Laser Doppler Anemometry) and thermocouples, respectively. And How fields are visualized by taking pictures of the How region with suspended particles. The results show the occurrence of a very effective circulation of the fluid in the whole How area as the heater and coolers are put into operation. In the remote region below the heated plate the new is nearly stagnant, and a remarkable temperature stratification can be observed with very thin thermal boundary. Analytical predictions using the FLUTAN code show a reasonable matching of the measured velocity fields.

  • PDF

Heat transfer coefficients for single-Phase flow in a micro-fin tube (마이크로휜 관내의 단상유동 열전달계수)

  • 권정태;김무환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.423-430
    • /
    • 1998
  • Single phase heat transfer coefficients were measured for turbulent water flow in a micro-fin tube by using Wilson plot technique. An experiment for counterflow heat exchange between the micro-fin tube and its outer annulus passage was performed. The annulus side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a micro-fin tube were obtained by Wilson plot technique. Nusselt numbers based on the real heat transfer area and the nominal area were about 35% and 50% larger than those for smooth tube respectively Also, single-phase heat transfer correlations based on real heat transfer area and nominal area have been proposed for a micro-fin tube.

  • PDF

Experimental Study on Heat Transfer and Pressure Drop Characteristics for Single-Phase Flow in Plate and Shell Heat Exchangers. (Plate and Shell 열교환기의 단상유동 열전달 및 압력강하 특성에 관한 실험적 연구)

  • 서무교;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.422-429
    • /
    • 2000
  • Plate and shell heat exchanger(P&SHE) is widely applied as evaporators or condensers in the refrigeration and air conditioning systems for their high efficiency and compactness. In order to set up the database for the design of the P&SHE, heat transfer and pressure drop characteristics for single phase flow of water in a plate & shell heat exchanger are experimentally investigated in this study. Single phase heat transfer coefficients were measured for turbulent water flow in a plate and shell heat exchangers by Wilson plot method. The shell side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a plate side were obtained by Wilson plot method. Single-phase heat transfer correlations based on projected heat transfer area and friction factor correlations have been proposed for single phase flow in a plate and shell heat exchanger.

  • PDF

Experimental Study on Heat Transfer Characteristics for Single-phase Flow in Plate & Shell Heat Exchangers by Using Wilson Plot Method (Wilson plot법을 이용한 Plate & Shell 열교환기의 단상유동 열전달 특성에 관한 실험적 연구)

  • Seo, M.K.;Kim, Y.S.;Lee, S.K.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.22-27
    • /
    • 1999
  • Single phase heat transfer coefficients were measured for turbulent water flow in a plate & shell heat exchangers by using Wilson plot method. An experiment for counterflow heat exchange between the plate and shell was performed. The shell side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a plate side were obtained by Wilson plot method. Single-phase heat transfer correlations based on projected heat transfer area have been proposed for a plate & shell heat exchanger.

  • PDF

The Study of Single Phase Source Stability consider for The DSC Cell's Operation Character by controlled Peed-back Circuit (DSC동작 특성에 따른 피드백제어를 통한 단상 전원의 안정화에 관한 연구)

  • Kim, Jin-Young;Park, Sung-June;Jung, Jong-Jin;Yoo, Dong-Wook;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.677-679
    • /
    • 2005
  • 최근 나노입자를 이용하는 광전 화학전지(PEC, Photoelectrochemical)인 염료감응형 태양전지(DSC)의 효율이 증가함에 따라 DSC 태양광 발전 시스템의 성능 개선 또한 요구되어진다. 본 연구에서는 Fly-Back DC-DC 컨버터(변화비율1:10)를 이용하여 DSC셀의 전압을 DC 300V로 승압시켰다. 또한 풀브릿지 인버터를 사용하여 AC 220V, 60Hz의 출력전압을 얻었다. 연구에서 제안한 회로는 높은 효율의 동작특성과 간단한 제작, 낮은 제조비용, 그리고 안정성을 추구한다. 또 다른 주요점은 부하단에서 Feed back을 받아 동작을 컨트롤하는 것이다. 부하단의 출력 전압과 전류를 Feed back 받아서 DSP320LF2406을 A/D기능을 사용하여 실시간으로 부하의 변화에 대처하여 컨버터와 인버터의 동작을 제어한다.

  • PDF

A Core Loss Calculation Method for AC Filter Inductor in PWM DC-AC Inverter (PWM DC-AC 인버터에서의 출력 AC 필터 인덕터 코아 손실 계산 방법)

  • Lee, Kyoung-Jun;Cha, Honnyong;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.38-39
    • /
    • 2011
  • 본 논문은 PWM DC-AC 인버터에서의 AC 필터 인덕터 코아 손실 계산을 위한 간단한 방법을 제시한다. 코아 손실 분석을 위해서 AC 필터 인덕터로 아몰퍼스 C-Core (AMCC-320)를 선택하였다. 단상하프브릿지 전압형 인버터와 간이 열량계를 이용하여 코아 손실을 측정하고 제시한 방법을 검증하였다. 기본적으로 인버터 스위칭은 SPWM 방법을 사용하였으며, 스위칭 주파수와 모듈레이션 인덱스를 가변하면서 실제 제작한 간이 열량계로 코아 손실을 측정하였다.

  • PDF

Boost Converter with Low-Loss Snubber Circuit (저손실 스너버 회로를 적용한 승압형 컨버터)

  • Ryu M. H.;Baek J. W.;Kim J. H.;Yoo D. W.;Min B. D.;Rim G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.700-703
    • /
    • 2004
  • 본 논문에서는 승압형 컨버터의 온/오프 스위칭 손실을 줄이기 위한 새로운 저손실 스너버 회로를 제안한다 제안하는 회로는 인덕터의 보조 권선을 통해 회로를 구성하며 부가되는 소자의 수가 작은 장점을 갖는다 제안하는 회로는 턴온 때에는 인덕터 보조 권선에 의해 스위치로 흐르는 전류의 상승을 제한하는 효과가 나타나므로 다이오드 역회복 전류에 의한 스위치 손실을 줄여준다. 동시에 턴오프시에는 스너버 회로를 통한 스위치 전압의 상승을 완만히 해주므로 역시 손실을 줄여준다. 본 논문에서는 1kW급의 단상 역률보상회로에 제안하는 회로를 구성하여 이의 동작을 검증하였다.

  • PDF

Experimental and Numerical Analysis for Single-phase Flow Pressure Drop in Parallel Micro-channels (병렬 채널에서의 단상 유동 압력 강하 특성에 관한 실험 및 수치해석)

  • Choi, Yong-Seok;Lim, Tae-Woo;You, Sam-Sang;Choe, Hyeong-Sik;Kim, Hwan-Seong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.5
    • /
    • pp.1090-1095
    • /
    • 2014
  • The experimental and numerical studies of the single-phase flow pressure drop in parallel micro-channels were performed. The parallel micro-channels consisted of 15 channels with depth 0.2mm, width 0.45mm and length 60mm. The FC-72 was used as the working fluid and the mass fluxes ranged from 62.8 to $1371.6kg/m^2s$. The numerical analysis was performed iterative calculations to solve governing equations and finds the appropriate value. The experimental data was compared with the numerical data, the results showed good agreement with the numerical data.