• Title/Summary/Keyword: 단부실험

Search Result 279, Processing Time 0.033 seconds

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Karyotype Studies on Three Species of the Family Muridae (Mammalia; Rodentia) in Korea (한국산 쥐과 3종의 핵형에 관한 연구)

  • Kang, Yung-Sun;Koh, Hung-Sun
    • The Korean Journal of Zoology
    • /
    • v.19 no.3
    • /
    • pp.101-112
    • /
    • 1976
  • 1. It has been found in the karyotype of Apodemus agrarius coreae that No. 1 chromosome pair is subtelocentric and this is the new chromosome type in comparison with acro-telocentric No. 1 pair of the other subpecies. 2. It was reported in the Karyotype of Microtus fortis from USSR that the autosome consisted of 2 submetacentric, 10 metacentric and 38 acrocentric chromosomes, and that X is acrocentric and Y is small acrocentric one. In the present study, however, the autosome of M. fortis pelliceus in Korea is composed of three groups; 4 subtelocentric, 10 meta-submetacenric, and 36 acrocentric one. And X is the largest metacentric chromosome of the complement. Y is smaller acrocentric one. Thus, it has been found that the karyotype of M. fortis in Korea differs from that of the same species in USSR. In the karyotype of this red vole, two pairs of heteromorohic chromosome with respect to the size of their secondary constrictions have been shown in the acrocentric group. 3. The diploid number of Cricetulus triton nestor was found to be 28, and its chromosome size ranges from 7.5 $\\mu$ to 1.5 $\\mu$. Autosomes contains 11 large acrocentric pairs and two pairs of very small metacentric ones. This feature is simillar to that of Tscherskia triton found USSR.

  • PDF

THE EFFECTS OF THE PLATELET-DERIVED GROWTH FACTOR-BB ON THE PERIODONTAL TISSUE REGENERATION OF THE FURCATION INVOLVEMENT OF DOGS (혈소판유래성장인자-BB가 성견 치근이개부병변의 조직재생에 미치는 효과)

  • Cho, Moo-Hyun;Park, Kwang-Beom;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.535-563
    • /
    • 1993
  • New techniques for regenerating the destructed periodontal tissue have been studied for many years. Current acceptable methods of promoting periodontal regeneration alre basis of removal of diseased soft tissue, root treatment, guided tissue regeneration, graft materials, biological mediators. Platelet-derived growth factor (PDGF) is one of polypeptide growth factor. PDGF have been reported as a biological mediator which regulate activities of wound healing progress including cell proliferation, migration, and metabolism. The purposes of this study is to evaluate the possibility of using the PDGF as a regeneration promoting agent for furcation involvement defect. Eight adult mongrel dogs were used in this experiment. The dogs were anesthetized with Pentobarbital Sodium (25-30 mg/kg of body weight, Tokyo chemical Co., Japan) and conventional periodontal prophylaxis were performed with ultrasonic scaler. With intrasulcular and crestal incision, mucoperiosteal flap was elevated. Following decortication with 1/2 high speed round bur, degree III furcation defect was made on mandibular second(P2) and fourth(P4) premolar. For the basic treatment of root surface, fully saturated citric acid was applied on the exposed root surface for 3 minutes. On the right P4 20ug of human recombinant PDGF-BB dissolved in acetic acid was applied with polypropylene autopipette. On the left P2 and right P2 PDGF-BB was applied after insertion of ${\beta}-Tricalcium$ phosphate(TCP) and collagen (Collatape) respectively. Left mandibular P4 was used as control. Systemic antibiotics (Penicillin-G benzathine and penicillin-G procaine, 1 ml per 10-25 1bs body weight) were administrated intramuscular for 2 weeks after surgery. Irrigation with 0.1% Chlorhexidine Gluconate around operated sites was performed during the whole experimental period except one day immediate after surgery. Soft diets were fed through the whole experiment period. After 2, 4, 8, 12 weeks, the animals were sacrificed by perfusion technique. Tissue block was excised including the tooth and prepared for light microscope with H-E staining. At 2 weeks after surgery, therer were rapid osteogenesis phenomenon on the defected area of the PDGF only treated group and early trabeculation pattern was made with new osteoid tissue produced by activated osteoblast. Bone formation was almost completed to the fornix of furcation by 8 weeks after surgery. New cementum fromation was observed from 2 weeks after surgery, and the thickness was increased until 8 weeks with typical Sharpey’s fibers reembedded into new bone and cementum. In both PDGF-BB with TCP group and PDGF-BB with Collagen group, regeneration process including new bone and new cementum formation and the group especially in the early weeks. It might be thought that the migration of actively proliferating cells was prohibited by the graft materials. In conclusion, platelet-derived growth factor can promote rapid osteogenesis during early stage of periodontal tissue regeneration.

  • PDF

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement (하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구)

  • Lim, Ju-Eun;Lim, Won-Hee;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.397-406
    • /
    • 2008
  • Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.

IN VITRO EVALUATION OF ACCURACY AND CONSISTENCY OF FOUR DIFFERENT ELECTRONIC APEX LOCATORS (4종 전자근관장측정기의 정확성과 일관성에 관한 in vitro 연구)

  • Cho, Jae-Hyun;Kum, Kee-Yeon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.390-397
    • /
    • 2006
  • The purpose of this study was to evaluate the accuracy and the consistency of four different electronic apex locators in an in vitro model. Fourty extracted premolars were used for the study. Four electronic apex locators (EAL) were Root ZX, Smarpex, Elements Diagnostic Unit (EDU), and E-Magic Finder Deluxe (EMF). After access preparation, the teeth were embedded in an alginate model and the length measurements were carried out at '0.5' and 'Apex' mark using four EALs. The file was cemented at the location of the manufacturers' instruction (Root ZX, EDU, EMF: 0.5 mark, SmarPex: Apex mark). The apical 4mm of the apex was exposed and the distance from the file tip to the major foramen was measured by Image ProPlus (${\times}100$). The distance from the file tip to the major foramen was calculated at 0.5 and Apex mark and the consistency of 0.5 and Apex mark was compared by SD and Quartile of Box plots. In this study, Root ZX and EMF located the apical constriction accurately within ${\pm}0.5 mm$ in 100%, whereas SmarPex and EDU located in 90% and in 70% respectively. For Root ZX and EMF, there was no significant difference between the consistency of 0.5 and Apex mark. However, for the EDU and SmarPex, Apex mark was more consistent than 0.5 mark. From the evaluation of the consistency in this study, for Root ZX and EMF, both 0.5 and Apex mark can be used as a standard mark. And for EDU and SmarPex, the Apex mark can be recommended to be used as a standard mark.

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

Relative efficacy of three Ni-Ti file systems used by undergraduates (학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교)

  • Kim, Hyeon-Cheol;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.38-48
    • /
    • 2005
  • The purpose of this study was to compare and evaluate the shaping ability of the three different Ni-Ti file systems used by undergraduate students. Fifty undergraduate students prepared 150 simulated curved root canals in resin blocks with three Ni-Ti file systems - $ProFile^{(R)}$ (PF), Manual $ProTaper^{(R)}$ (MPT), Rotary $ProTaper^{(R)}$ (RPT). Every student prepared 3 simulated root canals with each system respectively. After root canal preparation, the Ni-Ti files were evaluated for distortion or breakage Assessments were made according to the presence of various types of canal aberrations. The pre- and post-instrumented canal images were attained and superimposed. The instrumented root canal width were measured and calculated for the net transportation (deviation) and the centering ratio. Under the condition of this study, both $ProTaper^{(R)}$ systems allowed significantly more removal of root canal wall than the $ProFile^{(R)}$ system. In the important other aspects such as the centering ratio, there was no significant differences between the systems. Novice dental students were able to prepare curved root canals with any kinds of Ni-Ti file systems with little aberration and great conservation of tooth structure. Students want to learn effective methods and at the same time simple rotary procedures. The rotary $ProTaper^{(R)}$ systems were one of the most compatible to these students from the point of view of cutting ability The $ProFile^{(R)}$ system was also compatible in safe and gentle shaping.