• Title/Summary/Keyword: 단부슬립

Search Result 8, Processing Time 0.021 seconds

Crash Worthiness of a Post with Clip-type Slip Base Subject to Side Impact (클립형 단부분리장치를 갖는 지주의 측면충돌 시 충격완화효과)

  • Ko, Man-Gi;Kim, Kee-Dong;Kim, Kyoung-Ju;Sung, Jung-Gon;Yun, Duk-Geun
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.175-186
    • /
    • 2010
  • When a rigid post is exposed to traffic, it is hazardous not only to head-on impacts but also to side impacts. Clip-type slip base is an effective measure to reduce the severity of head-on impacts and side impacts as well because of its multi-directional release mechanism. Side impact tests were conducted and the results were analysed to demonstrate the hazardousness of a rigid post to a side impact and the crash worthiness of a post having clip-type slip base. For that, side impact test standard was made adapting the NCHRP Report 350, and 820kg-50km/h side impact tests were made for posts of D101.6mm(t=4.2mm) with and without slip base. Additionally, 35km/h side impact to the same post with slip base was conducted to check whether the clip-type slip base release mechanism works properly to the low impact speed. The tests revealed that the rigidly connected post was very hazardous to side impact while the post with the clip-type slip base reduced the impact severity tremendously.

Interface Behavior of Concrete Infilled Steel Tube Subjected to Flexure (휨을 받는 콘크리트 충전 강관의 계면거동)

  • Lee, Ta;Jeong, Jong-Hyun;Kim, Hyeng-Ju;Lee, Yong-Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.9-17
    • /
    • 2015
  • Interface behavior of concrete-infilled steel tube (CFT) was investigated based on the experimental observations and numerical analyses. Laboratory tests were performed for twelve CFTs that consisted of two different cases of diameters where each diameter case was composed of three different cases of shear span length. Thereby, diameter and shear span parameters were considered to prove the question of whether there exists interface slip between steel tube and infilled-concrete. Confining effect of steel tube to infilled concrete was also investigated by measuring lateral strain as well as longitudinal strain. Based on the study, it was concluded that confining effect of steel tube to infilled-concrete is not influential under flexural loading and therefore, the sectional analysis is an effective way to estimate the flexural strength of CFT.

Evaluation on the Shear Performance of U-type Precast Prestressed Beams (U형 PSC보외 전단거동 평가)

  • Yu Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.10-17
    • /
    • 2004
  • Shear tests were performed on four ends of full scale U-type beams which were designed by optimum process for the depth with a live load of 4903Pa. The ratio of width to depth of full scale 10.5 m-span, composite U-type beams with topping concrete was greater than 2. Following conclusions were obtained from the evaluation on the shear performance of these precast prestressed beams. 1) Those composite U-type beams performed homogeneously up to the failure load, and conformed to ACI Strength design methods in shear and flexural behaviors. 2) The anchorage requirements on development length of strand In the ACI Provisions preyed to be a standard to determine a failure pattern within the limited test results of the shallow U-type beams. 3) Those all shear crackings developed from the end of the beams did not lead to anchorage failure. However, initiated strand slip may leads the bond failure by increasing the size of diagonal shear crackings. 4) The flexural mild reinforcement around the vertical center of beam section was effective for developments of a ductile failure.

Interface Behavior of Concrete Infilled Steel Tube Composite Beam (콘크리트충전 강관 합성보의 계면거동)

  • Lee, Yong-Hak;Lee, Ta;Jeong, Jong-Hyeon;Kim, Hyeong-Ju;Park, Kun-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.9-18
    • /
    • 2014
  • Interface behavior and confining effects of concrete-infilled steel tube (CFT) composite beam were investigate based on the experimental observations and numerical analyses. For this purpose, laboratory four-points bending tests were performed for the two test specimens of 1,000mm long CFT composite beams. The test beams were made of ${\phi}110mm$ and 4.5mm thick steel tube and 10mm thick steel web and bottom flange. Therefore, concrete infilled in steel tube was in compression through the entire cross section due to the web and bottom flange. Two end section conditions, with end section cap and without end section cap, were considered in experiments to monitor the relative slip displacement at ends and induce confining effects at center. In numerical aspects, finite element analysis considering steel-concrete interface behavior was performed and compared to the experimental results.

Finite Element Analysis of Transfer Length in Pretensioned Prestressed Concrete Members (프리텐션 PSC부재의 전달길이 해석 및 예측에 관한 연구)

  • Oh Byung-Hwan;Lim Si-Nae;Choi Young-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.293-302
    • /
    • 2004
  • The transfer of prestress force in pretensioned prestressed concrete (PSC) members is of great concern because it affects directly the distribution of stress around the transfer zone. The design provision of current design code on the transfer length considers only the prestress intensity and the diameter of prestressing steels. However, other factors such as concrete compressive strength and concrete cover may affect greatly the transfer length. The purpose of the present paper is to explore the various factors that affect the transfer length in pretensioned PSC members. The bond stress-slip relation between prestressing steel and concrete was modeled first from experimental data and then this model was incorporated into the interface element. The interface element was used to perform the finite element analysis for pretensioned PSC members. The results indicate that the compressive strength and concrete cover are also very important parameters which affect the transfer length greatly. This means that the current design code, which considers only the effective prestress and diameter of prestressing steel, must be improved to take into account the other important variables of compressive strength and concrete cover. The present study allows more realistic analysis and design of pretensioned PSC members.

Effect of Vanadium Addition on the Cavitation Erosion Resistance of Fe-Cr-Ni-Si-C Hardfacing Alloy (Fe-Cr-Ni-Si-C계 경면처리 합금의 Cavitation Erosion 저항성에 미치는 Vanadium 첨가의 영향)

  • 김경오;김준기;장세기;김선진;강성군
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.72-72
    • /
    • 1998
  • 원자력발전소 1차계통내 밸브의 경면처리(hardfa따1잉에 사용되는 재료는 $90~343^{\circ}C$의 고온과 높은 접촉응력 그리고 급격한 압력변화가 일어나는 환경에서 사용되기 때문에 내마모성과 내식성 그리고 cavitation erosion 저항성이 우수한 Co계 Stellite 합금이 현재 사용되어진다. 그러나 Co가 원력발전소 1차계통의 방사선장을 형성하는 주요 원소로 알려지면서 S Stellite 합금을 대체할 수 있는 Fe계 경면처리용 합금을 개발하려는 연구가 진행되고 있다. 현재 Fe계 경면처리용 합금의 개발은 적절환 팝금원소를 첨가하여 적충결함에너지를 낮춤 으로써 전위의 교차슬립을 억제하여 표면을 경화시키고, 소성변형을 억제하여 마모저항성을 향상시키려는 방법으로 연구가 진행되고 있다. 본 연구에서는 Fe-Cr-Ni-Si-C 합금에 Fe계 합금의 적충결함에너지를 감소시키는 것으로 알려진 vanadium을 0, 1, 2wt%첨가하여 첨가량의 변화가 cavitation erosion 저항성에 미치 는 영향을 조사하였다. Cavitation erosion 실험은 초음파를 이용하여 미세한 기포를 발생시키는 vibratory type으로 A ASTM G-32 규격에 따라 제작된 실험장치를 이용하여 $25{\pm}2^{\circ}C$의 온도의 증류수 속에 잠긴 상태에서 실시하였다. 시면은 지름 16mm, 두게 7mm의 버턴형태로 vanadium 첨가량을 변화시킨 조성을 아크 용융 방법을 이용하여 제작하였으며 hom끝단부에 부착하여 cavitation e erosion 저항성 살험을 하였다. 시편의 cavitation erosion 실험시간에 따른 무게감소량을 측 정하였으며 cavitation erosion 시킨 시편의 표면을 SEM으로 관찰하였다.겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$

  • PDF

Flexural Performance of PHC Piles with Infilled concrete and Longitudinal Reinforcing Bars (속채움 콘크리트 및 길이방향 철근으로 보강된 PHC 파일의 휨성능)

  • Han, Sun-Jin;Lee, Jungmin;Kim, Min-Seok;Kim, Jae-Hyun;Kim, Kang Su;Oh, Young-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.77-84
    • /
    • 2021
  • In this study, flexural tests of prestressed high strength spun concrete (PHC) piles reinforced with infilled concrete and longitudinal rebars were conducted, where the longitudinal rebar ratio and the presence of sludge formed on the inner surface of PHC pile were set as key test variables. A total of six PHC pile specimens were manufactured, and their flexural behaviors including failure mode, crack pattern, longitudinal strain distribution in a section and end slip between external PHC pile and infilled concrete were measured and discussed in detail. The test results revealed that the flexural stiffness and strength increased as the longitudinal rebar ratio became larger, and that the sludge formed on the inner surface of PHC pile did not show any detrimental effect on the flexural performance. In addition to the experimental approach, this study presents a nonlinear flexural analysis model considering compatibility conditions and strain and stress distributions of the PHC piles and infilled concrete. The rationality of the nonlinear flexural analysis model was verified by comparing it with test results, and it appeared that the proposed model well evaluated the flexural behavior of PHC piles reinforced with infilled concrete and longitudinal rebars with a good accuracy.