• Title/Summary/Keyword: 단부보강 철골보

Search Result 17, Processing Time 0.026 seconds

Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-girder) (단부 보강한 합성보(에코거더)시스템의 구조성능에 관한 실험적 연구)

  • Chae, Heung-Suk;Ryoo, Jae-Yong;Chung, Kyung-Soo;Moon, Young-Min;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.533-541
    • /
    • 2010
  • H-shaped beams, which are constructed between columns, are used widely as slaves in steel structures. The bending moments that occur on both ends of an H-shaped beam, however, are about twice the bending moment that occurs at the center of the H-shaped beam. Because such beam is designed with maximum bending moment, it is deeper and has smaller spaces. To improve these features, if both ends of an H-shaped beam that have maximum bending moments are merely reinforced, the beams could be designed by the bending moment at the center of the H-shaped beam. To analyze the structural performance of the proposed end-reinforced beams (eco-girders). Four specimens were prepared with the following parameters: end-reinforced steel plate, reinforced bars, and reinforced studs and experimental tests of the specimens were performed.

An Analytical Study on Hysteresis Behavior of End-reinforced Steel-beam system(Eco-girder) (단부 보강한 합성보(Eco-girder)의 이력거동에 대한 수치해석적 연구)

  • Chae, Heung-Suk;Ryoo, Jae-Yong;Chung, Kyung-Soo;Moon, Young-Min;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.543-551
    • /
    • 2010
  • The end-reinforced composite-beam (eco-girder) system was developed that has characteristics of the existing composite beams such as reduced floor height and increased strength. With it, less use of steel is expected. In the eco-girder system, only both ends of the steel-frame beam, which are vulnerable to the ultimate moment, are reinforced with steel plates so that the steel frame beam design will be based on the moment at the beam center. This study used fiber element analysis, which is a simple representation and numerical integration of the principles of the detailed Finite Element Method(FEM), to predict the hysteretic behavior of reinforced composite beams under cyclic loading. The validity of the numerical method was verified by comparing the results of this study with those of previous studies. In addition, the hysteretic behavior of the eco-girder was compared with that of the existing composite beams.

Seismic Design of Steel Moment Connections with Welded Straight Haunch (용접 수평헌치로 보강된 철골 모멘튼 접합부의 내진설계)

  • 이철호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.73-81
    • /
    • 2000
  • 본 연구에서는 용접 수평헌치로 보강된 철골 모멘트 접합부의 내진설계법을 제시하고자 한다. 최근의 실험결과에 의하면 보의 하부를 수평헌치로 용접하는 방안은 취약한 내진성능이 드러나 기존 철골 모멘트 접합부의 내진보강이나 내진성능이 뛰어난 건물의 구축에 매우 효과적임을 알 수 있다. 용점 삼각헌치로 보강된 접합부의 설계법은 최근에 미국의 연구자들에 의해 제시된 바가 있다. 그러나 이 설계법은 응력 전달 메커니즘이 상이한 수평헌티 접합부의 설계에는 적용될수 없다. 본 논문에서는 우선 수평헌치와 보의 상호작용 및 변형의 적합 조건을 고려하여 도출된 단순화된 해석적 응력전달 모형을 간략히 기술한다. 이를 기초로 수평헌치 접합부의 단계별 내진 설계절차를 제안한다. 아울러 헌티단부의 응력집중을 줄이는데 매우 효과적인 디테일도 제시하고자 한다.

  • PDF

Analytical Study on Strength Resistance of Steel Beams with Stiffened Ends by Reinforced Concrete -difference of behavior with fixing plate- (복합보의 내력성능에 관한 연구 -정착판의 설치에 의한 거동의 차이-)

  • Kim, Seong Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.681-690
    • /
    • 2000
  • Recently, a long span is often required for the spacious building. Therefore the increase of stiffness is necessary to prevent floor vibration and control deformation of the building under earthquake and wind loads. For this purpose, steel beams with stiffened ends by reinforced concrete are effective. To realize such an effective reinforcement method, the smoothening of bending and shear stress transmission at the boundaries between middle-part of the steel beam and both end-parts of the steel beam with stiffened ends by reinforced concrete is required. Therefore, the fixed plate was installed at the boundary with the view of transferring the stress smoothly. This paper evaluates the method of effective transmission of bending and shear stress through the numerical analysis that is based on advanced experimental tests.

  • PDF

An Experimental Study on the Behavior of Hybrid Beam Composed of End Reinforced Concrete-Center Steel (단부 철근콘크리트-중앙부 철골로 구성된 복합(複合)보의 거동(擧動)에 관한 실험적 연구)

  • Kang, Byung Su;Kim, Seong Eun;Choi, Hyun Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.3
    • /
    • pp.413-421
    • /
    • 2002
  • This study sought to understand the mechanical behavior according to the shape of the connecting part of the hybrid beam. This part is composed of central steel. with the end reinforced by concrete in the experiment of cyclic loading. The experimental result was compared and verified with the ultimate strength formula. Likewise, the composite effect and the effectiveness of seismic capacity and stress transmission were examined. The types of each setup were as follows: main bars by welding type, reinforcing by end-plate type, reinforcing by shear connector type, and shear connector type. Results showed that the reinforcing by end-plate type and the shear connector type had excellent strength and seismic capacity as well as better stress transmission. This was due to the unity between reinforced concrete and the steel's connecting part. However, the experimental result was somehow different from the previously established ultimate strength formula. Thus, a definite ultimate strength formula is required.

An Experimental Study of Cyclic Seismic Behavior of Steel Moment Connections Reinforced with Ribs (리브로 보강된 철골 모멘트 접합부의 내진거동에 관한 실험적 연구)

  • Lee, Cheol Ho;Lee, Jae Kwang;Jung, Jong Hyun;Oh, Myeong Ho;Koo, Eun Sook
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.499-508
    • /
    • 2002
  • A simple design method for rib-reinforced seismic steel moment connections has been recently proposed based on the equivalent strut model. An experimental program was implemented to verify the proposed design method, as well as develop the schemes that will prevent cracking at the rib tip where stress concentration was evident. All specimens designed using the proposed method were able to develop a satisfactory connection plastic rotation of 0.04 radian. In addition to rib reinforcement, slight beam flange trimming pushed the plastic hinging and local buckling of the beam away from the rip tip and effectively reduced cracking potential at the rib tip. Using strain gage readings, the strut action of the rib and resulting reverse shear in the beam web were also experimentally identified.

Cyclic Seismic Testing of Steel Moment Connections Reinforced with Welded Straight Haunch (용접 수평헌치로 보강된 철골 모멘트 접합부의 반복재하 내진실험)

  • 이철호;권근배;정종현;오명호;구은숙
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.31-37
    • /
    • 2002
  • Recently a simplified design procedure as well as load transfer model for seismic steel moment connections with welded straight haunch have been proposed by Lee and Uang. Cyclic seismic testing was conducted to verify the proposed design procedure and to develop the details that will prevent the cracking at the haunch tip, where stress concentration was the highest. All the specimens thus designed effectively pushed plastic hinging away from the haunch tip and were able to develop satisfactory plastic rotation capacity of 0.04 radian with no fracture. A sloped edge combined with drilling a hole near the haunch tip or a pair of stiffeners(partially or fully) extended from the beam web successfully prevented the crack initiation at the haunch tip. The strut action of the haunch web, which had been predicted from the previous analytical study, was also experimentally identified through the strain gage readings.

Capacity Evaluation of Composite Beams Composed of End-Reinforced Concrete and Center-Steel (단부 RC조 중앙부 S조로 이루어진 합성보의 내력 평가)

  • Lee, Seung Jo;Park, Jung Min;Kim, Ki Wook;Kim, Wha Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.2 s.75
    • /
    • pp.151-159
    • /
    • 2005
  • This study investigated the capacity evaluation of composite beam of the end-reinforced concrete, the center steel with attached main-bar of stud-bolt welting and flange with main parameter, such as shear span depth ratio (a/d=1.5, 2.5, 3.5), reinforcing method, reinforcing length, and steel main-bar ratio. The test results are summarized as follows: As the RC section becomes longer, the capacity ratio of Vsrc, test/Vsrc, the gradually decreased, with the tendency of decrease being remarkably more than a/d=3.5. The reinforcing method showed superior result both vertically and horizontally. And, capacity increase ratio displayed tendency that main-bar fixing length is obvious in 0.15L, and underestimate experimental value usually in Vsrc, Eq(3)~(5) equation. The capacity estimation was proposed equation by regression analysis with change of shear span depth ratio and main-bar fixing, steel main-bar ratio.

Deformation Capacity of Existing Moment Connections retrofitted with Horizontal Stiffeners (수평스티프너로 보강된 모멘트 접합부의 변형능력)

  • Oh, Sang-Hoon;Kim, Young-Ju;Moon, Tae-Sup
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.220-227
    • /
    • 2005
  • 최근에 수행된 철골모멘트 접합부의 실험 및 해석결과에 의하면, 기둥으로 각형강관을 가진 접합부가 H형강을 기둥으로 사용하는 접합부에 실험체에 비해서 조기에 스캘럽 단부에서 취성파단이 발생하는 열등한 변형능력을 나타냈다. 이는 각형강관 기둥의 면외변형에 따른 보 웨브의 모멘트 전달효율의 저하, 스캘럽이 가지는 노치효과 및 합성보의 구속효과가 주요원인으로 밝혀졌다. 실험결과는 또한 개선된 수평스티프너로 하부 플랜지를 보강한 실험체는 우수한 변형능력을 가짐을 보였다. 본 연구에서는 이러한 영향을 고려하여, 다양한 수평스티프너로 보강된 접합부에 관한 유한요소해석을 실시하였다. 해석결과를 바탕으로 파일럿 테스트를 실시한 결과, 수평스티프너로 보강된 RBS 접합부 (SR)와 연장된 수평스티프너를 가진 접합부(LH)는 우수한 변형능력을 보였다.

  • PDF