• Title/Summary/Keyword: 단면 검사

Search Result 210, Processing Time 0.021 seconds

Evaluation of Gastric Motility with Ultrasonography in Conscious Minipigs (초음파를 통한 미니돼지의 위 운동성 평가)

  • Oh, Sun-Kyoung;Chang, Jin-Hwa;Jung, Joo-Hyun;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.574-577
    • /
    • 2009
  • The purpose of this study is to evaluate gastric motility of conscious minipigs with ultrasonography from contraction number of the pyloric antrum and gastric emptying time (GET). Five-month-old, clinically healthy minipigs weighing 13.5-15 kg were used for this experiment. Assessment of gastric motility was performed using saline (10 ml/kg) in all five minipigs. Contraction number of the pyloric antrum for 3 minutes and gastric emptying time were calculated. Gastric emptying time was considered to be the time at which the antral area returned to the basal value. The mean value of contraction number of the pyloric antrum before feeding was 1.60${\pm}$2.30 (mean${\pm}$SD) for 3 min and the overall mean value after saline administration was 5.40${\pm}$3.62 for 3 min. The mean value of GET by area was 58.06${\pm}$5.23 min. This data can be used as basic database for evaluation of gastric motility in minipigs as normal and various experimental models.

The Objective Image Analysis for HCC and HH with a Axial Image of Liver CT Scan (Liver CT 단면영상에서 간세포암과 간혈관종의 객관적 영상분석)

  • Hwang, In-Gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.411-417
    • /
    • 2015
  • To distinguish between HCC and HH is one of the important test methods in determining the treatment method by determining the treatment method by distinguishing malignant growth and benign tumors in liver CT scan. Currently, the specialist is reading CT images by their subjective judgment. So, the purpose of this study is to treat reading the CT images even more objective way. The test times after injection contrast medium in this study are the before injection phase(Pre.), artery phase(35sec), portal phase(70sec) and delay phase(180sec). The general pattern change of HCC in change of contrast enhancement pattern shows 26.6% matching. And the case of HH shows 16.6% matching. In order to observe the change of HU value between HCC and HH, each average values and standard deviation was confirm and as a result, it shows the lagre difference between artery and portal phase in lesion.(HCC$19.76{\pm}23.52$, HH$60.23{\pm}29.43$). And it shows the 76.6% matching in HCC and 80.0% matching in HH. Thorough this study, to suggest a HU value as objective analysis method and if the anlaysis method was used in clinical will assist in the diagnosis.

A Study on the Measurement of Axial Cracks in the Magnetic Flux Leakage NDT System (자기누설 비파괴 검사 시스템에서 축방향 미소결함 측정에 관한 연구)

  • Kim, Hui-Min;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu;Koo, Sung-Ja
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • From among the NDT (Non-Destructive Testing) methods, the MFL (Magnetic Flux Leakage) PIG (Pipeline Inspection Gauge) is especially suitable for testing pipelines because the pipeline has high magnetic permeability. MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is difficult to detect the crack which occured by exterior-interior pressure difference in pipelines and the shape of crack is very long and narrow. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The CMFL (Circumferential MF) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). By Simulating and Measuring the magnetic leakage field, it is possible to detect of axial cracks in the pipeline.

Survey of Asbestos-Related Disease on Chest Radiograph of Workers Exposed to Asbestos in Ship Repair (조선수리업종 석면노출 근로자들의 흉부방사선상 석면관련 폐질환 소견의 발생양상)

  • Lee Hyun Jae;Hong Young Seoub;Son Ji Eun;Lee Young Ill;Kim Sang Hoon;Im Hyoung June;Kim Jung Man;Kim Joon Youn
    • Journal of Life Science
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2006
  • There was cross-sectional study on investigating the factors related asbestos-related disease on chest radiograph of workers exposed to asbestos in ship repair. According to Occupational Safety & Health Administration asbestos standard, medical surveillance, chest radiologic study, pulmonary function test and medical questionnaire are performed in 118 subjects exposed to asbestos for 10 years or more in ship repair. The sixteen out of 118 subjects $(13.6\%)$ were observed asbestos-related disease finding on chest radiography. Significant factors related to those finding on chest radiography were abnormal pulmonary function test, cough, sputum, past history of respiratory disease, work duration. Workers with Significant factors related asbestos-related disease finding on chest radiography should be managed on a strict program. Further, factors unrelated with asbestos-related disease finding on this study should be evaluated prospectively for medical surveillance program of workers exposed to asbestos.

Physicochemical Properties and Sensory Evaluation of Meat Analog Mixed With Different Liquid Materials as an Animal Fat Substitute (동물성 지방 대체재로 첨가된 액상 재료에 따른 식물성 고기의 이화학적 특성 및 관능검사)

  • Kim, Honggyun;Bae, Junhwan;Wi, Gihyun;Kim, Hyo Tae;Cho, Youngjae;Choi, Mi-Jung
    • Food Engineering Progress
    • /
    • v.23 no.1
    • /
    • pp.62-68
    • /
    • 2019
  • In this study, the physical and sensorial properties of the meat analog were studied for the purpose of improving sensory preference and mimicking animal meat. The meat analog was made with different types of liquid materials such as oil, water, lecithin, polysorbate 80, or the emulsion of these components. At the aspect of density, the sample mixed with oil was higher than the sample mixed with water. Cooking loss value was higher at the sample with water than the sample with oil and this was the result opposite to the liquid holding capacity analysis. Also, texture profile analysis result showed that the samples with medium chain triglycerides (MCT) oil only showed the highest values in all attributes except for adhesiveness. Principal component analysis was carried out to analyze sensorial properties and it showed that the overall acceptance was high when the juiciness and softness increased. This result was highly related with the addition of emulsion. Therefore, emulsion technology can be a good candidate for improving the quality of meat analog and for mimicking the taste of animal meat.

Development of Deterioration Diagnosis System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화진단시스템 개발)

  • 김성덕;이승호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • Design and experiments of a nondestructive testing system with a solenoid eddy current sensor to inspect deterioration of ASCR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wires) usually used in HV overhead distribution lines in domestic areas in presented in this paper. Through corrosion mechanisms and deterioration results for ACSR-OC conductors are examined, it is shown that corrosion may lead to the reduction of the effective cross section area of conductors is proposed. The measurement system consisting of a constant current source with a RF frequency, a signal processing unit and a motor driver/ controller is designed and implemented. This instrument has such capabilities as detecting the sensor output and estimating diameter change of the testing conductors, continuously. As a result, it was verified that such corrosion detector system with an eddy current sensor can be shown good effectiveness for estimating the serious faults due to deterioration in overhead distribution lines and giving an early warming before severe aged conductor may lead to fail.

  • PDF

Development of Infrared Imaging Measurement Device for Internal Red Ginseng Analysis. (홍삼 내부 분석을 위한 적외선 영상 측정기기 개발)

  • Park, Jaeyoung;Kim, Taehoon;Jung, Seokhoon;Kim, Donggeun;Cho, Se-Hyoung;Han, Chang Ho;Lee, Sangjoon;Lee, Ji Yeon;Ko, Kuk Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.573-576
    • /
    • 2017
  • 본 연구는 홍삼 등급판정 과정에서 내부 조직 치밀도 분석을 위해 의료 영상 분석 방법을 이용하여 적외선 영상 측정기기를 개발하였다. 기존 홍삼 내부분석방법은 수동으로 암실환경에서 강한 조명을 홍삼에 투과하여 사람 눈으로 직접 판별하는 과정을 거친다. 이러한 기존 검사 과정은 작업 비효율성과 불균일한 검사기준으로 제품 품질 신뢰도 저하의 단점을 가져온다. 이러한 문제점을 해결하기 위해 본 연구는 적외선 조명환경에서 자동 측정이 가능한 홍삼 내부 측정기기를 개발하였다. 개발된 장치는 홍삼의 빛 투과 특성을 응용한 920nm 파장대역의 적외선 조명기구, 조명 제어회로, 적외선 대역 촬영이 가능한 영상 측정 카메라 장치, $0.9^{\circ}$의 간격으로 $360^{\circ}$ 홍삼 영상취득이 가능한 회전 엑츄에이터로 구성이 된다. 본 연구에서 제안 하는 홍삼 단층 영상분석 방법은, 홍삼을 $0.9^{\circ}$ 간격으로 회전시키어 $360^{\circ}$ 홍삼 내부영상을 취득하여 라돈 변환(Radon transform)을 통해 사이노그램(Sinogram)으로 재구성 하였으며, 역 라돈 변환(Inverse Radon transform)을 통해 단층 영상복원(Back-projection)알고리즘을 구현하였다. 이 결과 홍삼을 절단하지 않고 홍삼 내부 단면영상 획득이 가능하였으며 내공(內空), 내백(內白)의 유무를 판단하고 직경을 파악할 수 있었다. 이를 토대로 등급 판별 공식을 산출하면 신뢰성 있는 홍삼 등급 자동화 측정기기를 개발할 수 있을 것으로 기대된다.

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Quantitative Evaluation of Fiber Dispersion of the Fiber-Reinforced Cement Composites Using an Image Processing Technique (이미지 프로세싱 기법을 이용한 섬유복합재료의 정량적인 섬유분산성 평가)

  • Kim, Yun-Yong;Lee, Bang-Yeon;Kim, Jeong-Su;Kim, Jin-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.148-156
    • /
    • 2007
  • The fiber dispersion in fiber-reinferced cementitious composites is a crucial factor with respect to achieving desired mechanical performance. However, evaluation of the fiber dispersion in the composite PVA-ECC (polyvinyl alcohol-engineered cementitious composite) is extremely challenging because of the low contrast of PVA fibers with the cement-based matrix. In the present work, a new evaluation method is developed and demonstrated. Using a fluorescence technique on the PVA-ECC, PVA fibers are observed as green dots in the cross-section of the composite. After capturing the fluorescence image with a charged couple device (CCD) camera through a microscope, the fiber dispersion is evaluated using an image processing technique and statistical tools. In this image processing technique, the fibers are more accurately detected by employing an enhanced algorithm developed based on a discriminant method and watershed segmentation. The influence of fiber orientation on the fiber dispersion evaluation was also investigated via shape analyses of fiber images.

Comparative Analysis of the Weight Functions for the Reconstruction of a Gamma-ray CT based on the EM Technique (EM기반의 감마 CT 영상복원을 위한 가중치 함수 비교분석)

  • Lee, Na-Young;Jung, Sung-Hee;Kim, Jong-Bum;Kim, Jin-Sup;Kim, Jae-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.449-458
    • /
    • 2007
  • In this paper, we reconstructed the cross-sectional images of two phantoms simulating a petrochemical process from gamma radiation measurements. Three different weight functions for EM image reconstruction algorithm were built and compared with histograms representing the variance of the homogeneity of the phantom material, The radiation source, $^{137}Cs$, collimated by a lead with 5 mm diameter aperture and the measurement was made with a lead shielded 1inch NaI detector. As a result, the method taking into account the beam area in each pixel for a weight function showed the best resolution among the three methods.