DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법 (Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop)

  • 이기옥;유병규;유권종;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

스마트 그리드 내 독립전원의 단독운전 방지를 위한 무선 센서 네트워크 기반의 원격 전력 감시 시스템 (Wireless Sensor Network based Remote Power Monitoring System for Anti Islanding application in Smart-Grid)

  • 김기민;이경중;문찬우;안현식;정구민
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.57-62
    • /
    • 2010
  • 최근, 산업현장의 전력분야에서는 신재생 에너지와 스마트 그리드에 관심이 모아지고 있다. 스마트 그리드는 기존 전력망에 정보통신기술을 접목하여 전력망의 신뢰성, 효율성, 안전성을 향상시키고, 전력의 생산 및 소비 정보를 양방향, 실시간으로 모니터링하면서 에너지 효율을 최적화하는 차세대 전력망 기술이다. 그러나 스마트 그리드 내의 원격 모니터링 시스템들은 대부분의 유선망을 이용하는데, 유선망은 소규모 발전기에는 설치하기 어려운 단점이 있다. 본 논문에서는 스마트 그리드 내에서의 통신거리 제약 등의 여러 가지 문제점을 해결하기 위하여 센서네트워크를 기반으로 하는 원격 전력 모니터링 시스템을 구현한다. 또한, 구현된 시스템을 이용하여 새로운 분산전원 단독운전 방지 기법을 제안하고 실험을 통하여 검증하고자 한다.

병렬연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법 (Anti-Islanding Scheme for a Number of Grid-connected Inverters under Parallel Operation)

  • 김동균;박관남;조상윤;이영권;유권종;송승호;최익;최주엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.351-352
    • /
    • 2016
  • Since anti-islanding scheme of grid-connected inverter is a key function of standards compliance, unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, existing anti-islanding schemes show poor power quality and non-detection zone issues. Besides, most of them have problems which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proposes a new anti-islanding scheme that has both negligible power quality degradation, no non-detection zone and precise islanding detection under parallel-operation. Finally, both simulation and experimental results validate the proposed scheme.

  • PDF

Goertzel 알고리즘을 이용한 새로운 단독운전 방지 기법 (A novel anti-islanding method using Goertzel Algorithm)

  • 원동조;김재형;김준구;원충연;이태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.299-301
    • /
    • 2009
  • In this paper, a novel anti-islanding method of DC-AC single phase inverter is proposed. The inverter injects a little harmonic current with the output current of a PCS(Power Conditioning System). When the islanding condition is occurred, the voltage harmonic components appear on the output voltage of the PCS due to the injection of a little harmonic current. So, the PCS detects the voltage harmonic components using the Goertzel algorithm, and then the PCS decides that the islanding condition is occurred. When the PCS recognizes the islanding condition, the PCS are stopped. The proposed a novel anti-islanding method is analyzed, and its validity is proven through simulation.

  • PDF

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법 (Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load)

  • 오형민;최세완;김태희;이기풍;이태원
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법 (A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System)

  • 강성욱;김경화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

분산전원 시스템의 주파수 변동을 통한 단독운전 방지기법 분석 (Analysis of Anti-Islanding Schemes using Frequency Drift in Distributed Generation System)

  • 조영민;조상윤;송승호;최익;최주엽;이영권
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.247-254
    • /
    • 2015
  • Unintentional islanding results in safety hazards, power quality degradation, and many other issues. Thus, islanding detection of grid-connected distributed generation system is a key function for standards compliance. Many anti-islanding schemes are currently being studied; however, existing anti-islanding schemes used in inverters have power quality degradation and non-detection zone issues. Therefore, this paper analyzes existing anti-islanding schemes by using frequency drift in accordance with both islanding detection performance and power quality. This paper also proposes a new anti-islanding scheme by using frequency drift. Both simulation and experimental results show that the proposed scheme has negligible power quality degradation and no non-detection zones compared with other existing schemes.

단일용량 120kW급 계통연계형 태양광 발전용 PCS 개발 (Development of Unitary 120kW PCS for Grid-Connected Photo-Voltaic Power Generation)

  • 신영찬;문준선;나병훈;김영록;김신섭;안교상;임희천
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.188-190
    • /
    • 2006
  • 본 논문에서는 국내최초로 개발에 성공한 단일용량의120kW급 계통연계형 태양광발전용 PCS에 관한 내용을 설명하고 있다. 120kW급 계통연계형 태양광발전시스템은 22.9kV의 특고압 계통전원에 연계되도록 설계되었으며, 삼상 380V를 22.9kV로 승압 연계하는 2단 절연방식을 채택하였다. 120kW급 PCS는 상용주파수 변압기 절연방식으로 3상4선식 380v 60H2 출력을 가지고 있으며, PCS 내부에 120kVA급 변압기와 리액터를 포함하고 있다. 최대출력점추종(MPPT)제어 기법으로 P&O 알고리즘을 적용하였으며, 3상 IGBT 인버터를 DSP로 제어하였다. 본 논문에서는 120kW급 단일용량 PC를 개발함에 있어, 계통연계 시험, 유,무효 전류제어 시험, 단독운전 검출 및 방지시험, 출력전류의 THD 측정 등의 결과를 보이고 있다.

  • PDF

200kW급 태양광발전용 계통연계형 인버터의 개발 (Development of 200kW Grid-Connected Photovoltaic Inverter)

  • 김영록;나병훈;문준선;손용훈;신영찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.527-529
    • /
    • 2007
  • 본 논문에서는 120kW급에 이어 단일용량 200kW급 태양광발전용 계통연계형 인버터의 개발에 관한 내용을 설명하고 있다. 200kW급 계통연계형 태양광발전시스템은 22.9kV의 특고압 계통전원에 연계되도록 설계되었으며, 삼상 380V를 22.9kV로 승압 연계하는 2단 절연방식을 채택하였다. 200kW급 인버터는 상용주파수 변압기 절연방식으로 3상4선식 380V 60Hz 출력을 가지고 있으며, 인버터 내부에 200kVA급 변압기와 리액터를 포함하고 있다. 최대 전력점 추종(Maximum Power Point Tracking, MPPT)제어 기법으로 P&O 알고리즘을 적용하였으며, 3상 IGBT 인버터를 DSP로 제어하였다. 본 논문에서는 200kW급 단일용량 인버터를 개발함에 있어, 계통연계 시험, 단독운전 검출 및 방지 시험, 발전량에 따른 효율과 THD 측정 등의 결과를 보이고 있다.

  • PDF

향상된 고조파 검출 능력을 갖는 계통연계 인버터의 하이브리드 단독운전 방지기법 (A Hybrid Anti-islanding Detection Scheme for Utility Interactive Inverter with Enhanced Harmonic Extraction Capability)

  • 강성욱;김경화
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.312-319
    • /
    • 2014
  • When distributed generation such as a wind power system is connected to the grid, it should meet grid requirements like IEEE Std. 1547, which regulates the anti-islanding method. Since the islanding may cause damage on electrical equipments or safety hazards for utility line worker, a distributed generation should detect it as soon as possible. This paper proposes a hybrid anti-islanding method coupled with the active and passive detection methods. To enhance the harmonic extraction capability for an active harmonic injection method, cascaded second-order band-pass filter and signal processing scheme are employed. Simulation and experiments are carried out under the islanding test condition specified in IEEE Std. 1547. Passive over/under voltage and over/under frequency methods are combined with the active method to improve the detection speed under certain condition. The simulation and experimental results are presented to verify that the proposed hybrid anti-islanding method can effectively detect the islanding.