• 제목/요약/키워드: 단광

검색결과 17건 처리시간 0.022초

자기 환원성 TiO2 단광의 반응특성에 관한 연구 (Study on the Reaction Behavior of Self-reducing TiO2 Briquette)

  • 백상종;신동엽;민주원;최석우;윤덕재;유병돈
    • 소성∙가공
    • /
    • 제15권8호
    • /
    • pp.615-620
    • /
    • 2006
  • The reduction behavior of $TiO_{2}$ in Al and Al/CaSi containing self-reducing $TiO_{2}$ briquettes(SRTB) was investigated. The maximum yield of Ti was expected with the slag composition of 45-55%CaO in the $CaO-Al_{2}O_{3}$ system. When $CaCO_{3}$ was used as a flux, the oxidation loss of reducing agent by $CO_{2}$ should be compensated, and therefore it leads to excessive requirement of the reducing agent. By using Al and CaSi mixture as a reducing agent of $TiO_{2}$, the reaction products both oxide and metal could be liquefied, and separated effectively with each other. As a result, the yield of Ti increases remarkably. The optimum mixing ratio of CaSi to Al is 78%CaSi-22%Al.

Au-ZnO 나노복합체의 국부화된 플라즈몬 효과에 따른 유기발광소자의 효율 향상

  • 이용훈;김대훈;김태환
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.219-219
    • /
    • 2016
  • 유기발광소자는 저전력, 빠른 응답속도, 고휘도 및 자체발광 등의 장점들 때문에 고체 광원과 플렉서블 디스플레이로 연구가 진행되고 있다. 유기발광소자는 유기 발광층을 인광물질로 사용 함으로서 100 % 내부양자 효율을 이루고 있지만 공기와 유리기판의 계면과 유리 기판과 ITO 계면에서 발생하는 내부 전반사 효과와 유기물과 ITO 기판 사이에서 발생하는 웨이브 가이드 효과 등으로 인해 발광량의 약 20 %만을 외부로 추출 할 수 있다. 따라서 유기발광소자의 광 추출 효과를 증가시키기 위해서 소자외부에 아웃커플링 필름 또는 마이크로렌즈 어레이 필름을 부착시키는 방법, 금속 나노 입자를 유기발광소자 내에 삽입하여 표면 플라즈몬 효과로 인한 광추출 효율을 높이는 방법 등이 제시되고 있다. 본 연구에서는 Au-ZnO 나노복합체를 간단한 졸겔법을 이용하여 양극 버퍼층으로 사용하여 그에 따른 계면, 전기적 및 광학적 특성을 분석하였다. Au-ZnO 나노복합체를 포함한 tris(8-hydroxyquinolinato) aluminium (Alq3) 발광층에서 ZnO를 포함한 Alq3 발광층보다 엑시톤 수명이 빠르게 감소하는 것을 시간 관련 단광자 계산(Time-Correlated Single Photon Counting) 측정을 통해서 알 수 있었다. 이러한 결과는 Au 금속 나노입자의 플라즈몬 흡수 파장과 Alq3 발광층에서 생성되는 발광 파장이 겹쳐서 효과적인 공명 에너지 전달효과로 인해 Alq3 발광층의 발광성질이 향상된 것을 의미한다. Au-ZnO 나노복합체와 ZnO 나노입자를 가지는 유기발광소자의 전류 효율은 50 mA/cm2 에서 각각 2.27와 1.83 cd/A 가지는 것으로 확인 되었다. 또한 Au-ZnO 나노복합체와 ZnO 나노입자를 사용한 유기발광소자의 전압-전류밀도가 유사한 것을 확인 할 수 있는데 이는 Au 금속 나노입자가 ZnO 나노입자의 정공 주입능력을 저하시키지 않는 것을 의미한다.

  • PDF

액정성 고분자 블렌드의 편발광 (Polarized Light Emission of Liquid Crystalline Polymer Blends)

  • 김영철;조현남;김동영;홍재민;송남웅
    • 폴리머
    • /
    • 제24권2호
    • /
    • pp.211-219
    • /
    • 2000
  • 액정성을 가지는 플로렌계 발광고분자에 비버정성 플로렌계 발광고분자를 첨가한 블렌드를 제조하여 에너지전달 효과와 흡광 및 발광 이방성에 대하여 고찰하였다. 비액정성 고분자를 액정성 고분자에 0.5wt% 첨가하고 360nm로 여기한 결과, 420nm에서 관찰되었던 액정성 고분자의 발광피크는 거의 사라졌으며 대신 비액정성 고분자에 의한 480nm에서의 새로운 발광피크가 관찰되었다. 블렌드 시료의 480nm 발광은 비액정성 고분자가 2.0wt% 첨가되었을때 가장 강했으며, 발광강도는 블렌딩 이전의 각 고분자보다 13배 증자하였다. 블렌드내의 분자들을 마찰 폴리이미드 기판상에서 가열-냉각시켜 배향시키면 시료의 발광 이방성과 order parameter는 각각 2.0 및 0.25를 나타내었다. 시간 상관 단광자 계수법 (TCSPC)에 의해 고찰한 결과, 마찰 폴리이미드 기판상에서의 배향에 의해 두 발광고분자간의 에너지전달에 필요한 시간은 93 ps만큼 단축되며 에너지전달 효율은 9% 증가함을 알 수 있었다.

  • PDF

MEE 기법으로 성장한 InGaAs 양자점의 크기 변화에 따른 광발광 특성분석

  • 하승규;조남기;송진동;박재규;이동한;최원준;이정일
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.116-116
    • /
    • 2010
  • 단일 양자점의 특성 분석 및 이를 활용한 단광자 광원 등으로의 응용에 있어서 표면밀도 및 크기 등이 의도대로 조절된 양자점 성장이 필수적이며, 이와 관련하여 근적외선 파장 영역에서 발광 성분을 갖는 InGaAs/GaAs 양자점 시료를 MEE (Migration Enhanced Epitaxy) 기법으로 성장하였다. 이 때, 30 초 120 초 사이의 migration enhancing time 변화에 의하여 약 $350\;QDs/{\mu}m^2$에서 $3\;QDs/{\mu}m^2$ 사이의 범위로 양자점 표면 밀도가 조절되었으며 양자점의 크기도 변화하는 것을 확인하였다. 별도로 capping layer를 성장하지 않은 양자점 층에 대한 AFM 측정을 통하여 양자점의 크기를 예측하였으나, 실제 시료의 양자점 크기는 capping layer 성장시의 온도 및 압력에 따른 영향이나 물질 조성의 불균일성 등으로 인해 달라질 수 있으므로 비파괴 검사방법인 광발광 측정으로써 실제 양자점의 특성을 검증할 필요성이 존재한다. 먼저 양자점의 크기가 커짐에 따라 기저상태의 에너지 밴드갭 크기가 감소하는 경향이 있음을 확인하였다. 이는 양자점이 클수록 양자구속 효과가 작아지는 일반적인 경향과 일치한다. 또한, 양자점의 크기 차이에 따른 기저상태 및 고차 여기 상태의 에너지 밴드갭 차이의 변화 경향을 분석하였다. 일반적으로 양자점의 크기가 줄어들면 양자구속효과 또한 빠르게 증가하다가 결국에는 에너지 장벽(barrier)의 에너지 준위에서 포화상태에 도달하게 된다. 이러한 양자점 크기에 따른 양자구속효과 크기의 변화는 고차 여기 상태일수록 더욱 빠르며, 결국에는 양자 구속효과가 없어지는 상태(unbound exciton)에 이르기도 한다. 따라서 기저상태의 에너지 밴드갭은 양자점이 커짐에 따라 단조감소 경향을 보이나, 변화율의 차이 때문에 기저상태와 1차 여기상태의 에너지 차이인 level spacing 값은 단조감소 경향이 아닌 종 모양의 경향성을 보이며 측정 결과 또한 이와 일치하였다. 이와 같이 migration enhancing time의 조절로 광자와 상호작용하는 실질적인 양자점의 크기가 의도대로 조절되었음을 비파괴 광측정법으로 확인하였다.

  • PDF

SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화 (Variation on Estimated Values of Radioactivity Concentration according to the Change of the Acquisition Time of SPECT/CT)

  • 김지현;박훈희;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.645-653
    • /
    • 2021
  • With the recent development of precision medicine(Theranostics), interest and utilization of the quantitative function of SPECT/CT are increasing. This study aims to investigate the effect on the radioactivity concentration estimate by the increase or decrease in the total time of SPECT/CT imaging conditions. A standard image was obtained by the conditions of a total acquisition time of 600 sec(10 sec/f × 120 frames) by diluting 99mTc 91.76 MBq in a cylindrical phantom filled with sterile water, and a comparative image was obtained by increasing the total acquisition time by -90%, -75%, -50%, -25%, +50%, +100%. The CNR, radioactive concentration estimate(cps/ml), and the variation rate(%) of the recovery coefficient(RC) were analyzed by measuring the overall coefficient of interest in each image. The results[CNR, Radiation Concentration, RC] by the change in the number of projections for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results[CNR, Radiation Concentration, RC] by the acquisition time change for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at -90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Image quality(CNR) showed a pattern of change in proportion to the increase or decrease in the total acquisition time of SPECT/CT, but the result at quantitative evaluation showed a change of less than 5% in all experimental conditions, maintaining quantitative accuracy(RC less than 0.05) without much influence.

SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교 (The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images)

  • 김지현;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

골관절염을 가진 측두하악장애 환자의 치료 전, 후 골스캔과 SPECT의 평가 (The Evaluation of Bone Scan and SPECT Before and After Treatment of TMD Patients)

  • 김병수;안용우;고명연;박준상
    • Journal of Oral Medicine and Pain
    • /
    • 제30권1호
    • /
    • pp.57-67
    • /
    • 2005
  • 저자는 2000년 1월부터 2003년 12월까지 부산대학교병원 구강내과에 측두하악관절장애를 주소로 내원한 환자 중 임상검사와 방사선검사를 시행하여 측두하악관절의 골관절염으로 진단되어, 초진 시와 종결 시에 골스캔과 SPECT를 각각 촬영한 환자 27명을 대상으로 골스캔의 SUR 와 SPECT의 온점의 개수를 치료 전, 후로 비교하고 병력, 기여요인, 증상, 치료방법, 치료기간 등을 기준으로 골스캔의 SUR 과 SPECT의 온점의 개수를 비교 연구하여 다음과 같은 결과를 얻었다. 1. 골관절염에 이환된 관절군에서 치료 전 골스캔의 SUR 과 SPECT의 온점의 개수가 골관절염에 이환되지 않은 관절군에 비해 유의하게 높은 소견을 보였다(P<0.05). 2. 골관절염에 이환된 관절에서 치료 전 골스캔의 SUR 과 SPECT 온점의 개수가 보존적 치료 후에 유의하게 감소하였다(P<0.01). 3. 교합장치를 이용해서 치료한 군에서 골스캔의 SUR 과 SPECT 온점의 개수가 치료 후에 유의하게 감소하였다(P<0.01,P<0.05). 4. 만성군에서 치료 전 골스캔의 SUR 과 SPECT의 온점이 치료 후에 유의하게 감소하였다(P<0.05). 5. 관절음에 대한 불편감 정도가 낮은 환자군의 치료 전 골스캔의 SUR과 SPECT의 온점의 개수가 치료 후에 유의하게 감소하였다(P<0.01). 6. 외상 병력이 없고, 악습관이 있고, 정신사회적 배경이 없는 환자일수록 골스캔의 SUR과 SPECT의 온점의 개수가 치료전에 비해 치료후에 현저히 낮았다. 7. 초진 시 골스캔의 SUR과 SPECT의 온점의 개수가 높을수록 많은 치료기간이 필요하다.