• Title/Summary/Keyword: 단광자방출전산화단층영상

Search Result 3, Processing Time 0.015 seconds

Prediction of Infarction in Acute Cerebral Ischemic Stroke by Using Perfusion MR Imaging and $^{99m}Tc-HMPAO$ SPECT (급성 허혈성 뇌졸중에서 관류 자기공명영상과 99mTC-HMPAO 단광자방출단층촬영술을 이용한 뇌경색의 예측)

  • Ho Cheol Choe;Sun Joo Lee;Jae Hyoung Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.55-63
    • /
    • 2002
  • Purpose : We investigated the predictive values of relative CBV measured with perfusion MR imaging, and relative CBF measured with SPECT for tissue outcome in acute ischemic stroke. Material and Methods : Thirteen patients, who had acute unilateral middle cerebral artery occlusion, underwent perfusion MR imaging, and $^{99m}Tc-HMPAO$ SPECT within 6 hours after the onset of symptoms. Lesion-to-contralateral ratios of perfusion parameters were measured, and best cut-off values of both parameter ratios with their accuracy to discriminate between regions with and without evolving infarction were calculated. Results : Mean relative CBV ratios in regions with evolving infarction and without evolving infarction were $0.58{\pm}0.27$ and $0.9{\pm}0.17$ (p < 0.001), and mean relative CBF ratios in those regions were $0.41{\pm}0.22$ and $0.71{\pm}0.14$ (p < 0.001). The best cutoff values to discriminate between regions with and without evolving infarction were estimated to be 0.80 for relative CBV ratio and 0.56 for relative CBF ratio. The sensitivity, specificity and efficiency of each cutoff value were 80.6, 87.5, 82.7% for relative CBV ratio, and 72.2, 75.0, 73.0% for relative CBF ratio (p > 0.05 between two parameters). Conclusion Measurement of relative CBV and relative CBE may be useful in predicting tissue outcome in acute ischemic stroke.

  • PDF

The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

Variation on Estimated Values of Radioactivity Concentration according to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.645-653
    • /
    • 2021
  • With the recent development of precision medicine(Theranostics), interest and utilization of the quantitative function of SPECT/CT are increasing. This study aims to investigate the effect on the radioactivity concentration estimate by the increase or decrease in the total time of SPECT/CT imaging conditions. A standard image was obtained by the conditions of a total acquisition time of 600 sec(10 sec/f × 120 frames) by diluting 99mTc 91.76 MBq in a cylindrical phantom filled with sterile water, and a comparative image was obtained by increasing the total acquisition time by -90%, -75%, -50%, -25%, +50%, +100%. The CNR, radioactive concentration estimate(cps/ml), and the variation rate(%) of the recovery coefficient(RC) were analyzed by measuring the overall coefficient of interest in each image. The results[CNR, Radiation Concentration, RC] by the change in the number of projections for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results[CNR, Radiation Concentration, RC] by the acquisition time change for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at -90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Image quality(CNR) showed a pattern of change in proportion to the increase or decrease in the total acquisition time of SPECT/CT, but the result at quantitative evaluation showed a change of less than 5% in all experimental conditions, maintaining quantitative accuracy(RC less than 0.05) without much influence.