• Title/Summary/Keyword: 다중 제어밸브

Search Result 9, Processing Time 0.022 seconds

A study on the pressure controller design of multiple control valve structure (다중 제어밸브 구조의 압력제어기 설계에 관한 연구)

  • Shin, Suk-Shin;Park, Jong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.404-408
    • /
    • 2013
  • In this Study, another way to accomplish the goal of meeting large steam-flow requirements is the use of multiple valves. Multiple valves can provide better control in meeting the precision pressure controller requirements. Simulation demonstrates the effectiveness of the pressure controller. The key point of this study is to precisely control the position of the control valve on the outside of the electro-hydraulic system using a special PID controller. Simulation and experiments verify the performance of the controller.

Optimal Design of Multi-Fuzzy Controller and Its application to Air Conditioning System (다중 퍼지 제어기의 최적 설계와 에어컨 시스템으로의 적용)

  • Jang, Han-Jong;Choe, Jeong-Nae;O, Seong-Gwon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.313-316
    • /
    • 2008
  • 에어컨 시스템은 압축기(Compressor), 응축기(Condenser), 증발기(Evaporator)와 확장밸브(Expansion Valve)로 구성되며, 에어컨 시스템에서 과열도와 저압(증발기의 압력)은 시스템의 효율 증대 및 성능 개선과 안정성에 대하여 결정적인 영향을 미친다. 따라서, 과열도와 저압을 조절하기 위해, 각각의 압축기내의 인버터 주파수와 확장밸브의 개도 제어가 중요하며 선형과 비선형 시스템 모두에 대하여 견실한 성능을 나타내고, 외란에 대하여 강인한 성능을 보이는 퍼지 제어기를 설계한다. 본 논문에서는 과열도와 저압을 제어하기 위하여, 3대의 확장밸브와 1대의 압축기를 가진 에어컨 시스템에 대하여 다중 퍼지 제어기를 설계한다. 또한, 각 제어 플랜트에 대하여 최적의 퍼지 제어기를 설계하기 위하여 3가지 최적화 알고리즘을 사용한다. 즉, 직렬 유전자 알고리즘(Serial Genetic Algorithm; SGA)과 병렬 유전자 알고리즘인 계층적 공정 경쟁 유전자 알고리즘(Hierarchical Fair Competition Genetic Algorithm; HFCGA), 그리고 Particle Swarm Optimization(PSO)을 사용하여 다중 퍼지 제어기를 최적화하고 시뮬레이션의 결과를 비교한다.

  • PDF

Design of Optimized Multi-Fuzzy Controllers for Air-Conditioning System with Multi-Evaporators (다중 증발기를 갖는 에어컨시스템에 대한 최적화된 Multi-Fuzzy 제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Oh, Sung-Kwun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • In this paper, we introduce an approach to design multi-fuzzy controllers for the superheat and the low pressure that have an influence on energy efficiency and stabilization of aft conditioning system. Air conditioning system is composed of compressor, condenser several evaporators and several expansion valves. It is quite difficult to control the air conditioning system because the change of the refrigerant condition give an impact on the overall air conditioning system. In order to solve the drawback, we design multi-fuzzy controllers which control simultaneously both three expansion valve and one compressor for the superheat and the low pressure of air conditioning system. The proposed multi fuzzy controllers are given as two kinds of controller types such as a continuous simplified fuzzy inference type and a discrete fuzzy lookup_table type. Here the scaling factors of each fuzzy controller ate efficiently adjusted by veal coding type Genetic Algorithms. The values of performance index of the conventional type are compared with the simulation results of discrete lookup_table type and continuous simplified inference type.

Analysis on the Dynamic Characteristics of a DDV Actuation System of a FBW Aircraft (FBW 항공기의 DDV 구동장치에 대한 운동특성 해석)

  • Nam, Yun-Su;Park, Hae-Gyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.74-80
    • /
    • 2006
  • This paper deals with the control and fault monitoring of a DDV hydraulic actuation system. A hydraulic servo system has a nonlinear dynamics of an orifice flow through a valve spool. A full nonlinear model for a DDV actuation system is driven, and linearized to a simple model which is convenient for a control loop and fault monitor design. A top level requirement on the performance and safety for the actuation system is introduced. A control system and fault monitoring structure which can meet these requirements are discussed. A simulation package for a DDV actuation system which has a triplex redundant structure is developed.

Design of thermal system using 3-way valve and PTC to which a solar module (태양광 모듈이 부착된 PTC 집열기 및 3웨이 밸브를 이용한 온열 시스템 설계)

  • Song, Je-Ho;Lee, In-Sang;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.454-459
    • /
    • 2017
  • In this study, a thermal system was designed using a 3-way valve and PTC attached to a solar module. This design could help solve the problem of rising fossil fuel costs caused by limited reserves and environmental problems resulting from fossil fuel use. The thermal system is a hot-air and heating control system composed of a temperature sensor part, mode setting part (for hot air and heating modes), supply part, and thermal system control part. The temperature sensor part has piping and an indoor temperature display, and the temperature setting part has multiple monitoring functions. The mode setting part switches between hot air and heating modes and can be used to set the temperature. The thermal system control part performs functions such as PTC control and temperature setting, PTC day and night and time selection, hot air and heating control, and three-way valve selection. The results verify that the system operates with stable response speeds of $680{\mu}s$ in the temperature sensor part, $700{\mu}s$ in the mode setting part, and $610{\mu}s$ in the thermal system control part.

Digital Dilution Chip Based on Use of Selective Inter-well Valve Control (다중 밸브를 이용한 디지털 희석 소자)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.535-539
    • /
    • 2010
  • We present a digital dilution chip comprising a $2{\times}6$ array of wells; the chip can be employed to change the dilution ratio as well as to initiate reactions among diluted samples by using the inter-well valve around the well. In previous dilution devices, streams comprising sample and dilution solutions were merged and separated by a branched microchannel. Therefore, the dilution ratio could not be changed until the structure of the branched microchannel was changed. The present device merges and splits the wells filled with sample or dilution solution by controlling inter-well valves around the wells. Thus, it is possible to change the dilution ratio by changing the sequence in which merging and splitting sequence of each well filled with sample or dilution solution. In experiments, we found that the chip could be used to change linear or exponential dilution ratios within an error of 16.7% and to initiate reactions among the samples within a reaction error of 17.7%.

Development of a Walking-type Solar Panel Cleaning Robot Capable of Driving on Inclined Solar Panel (경사진 패널 위에서 주행이 가능한 보행형 태양광 패널 청소로봇 시스템 개발)

  • Park, Sunggwan;Jang, Woojin;Kim, Dong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.79-88
    • /
    • 2020
  • This paper propose the method to drive a solar panel cleaning robot efficiently on an inclined panel using vacuum pad pressure. In this method, the rubber pads using the vacuum pressure are used to attach robot body to the panel surface. By applying the linkage mechanism to the vacuum pads, it was possible to reduce robot weight and power consumption and to prevent slipping of the robot. In addition, the use of solenoid valves, proximity sensors, and encoders to detect movement of the robot body and the control of the pad pressure dedicate to the driving of the robot on an inclined panel. In order to move the robot forward, the operation sequence of multiple solenoid valves was completed, and the six vacuum pads mounted to both legs were accurately controlled to form vacuum and atmospheric pressure in right order so that the robot could move forward without slipping. At last, it was confirmed through experiments that straight-forward moving and rotational movement could be performed up to 36 degrees of inclination angle of solar panel.

Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring (Multi-measuring기법을 이용한 원전 제어밸브의 누설진단)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Bong-Ho;Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

A Study on the Control of Multi-Input Hydraulic System for Robot Leg using LQR Technique (LQR 기법을 이용한 로봇다리의 다중입력 유압시스템 제어에 관한 연구)

  • Yoo, Sam-Hyeon;Lim, Soo-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.540-547
    • /
    • 2009
  • In the near future, military robots are likely to be substituted for military personnel in the field of battle. The power system of a legged robot is considerably more complex than the one used for a land vehicle because of the coordination and stability issues due to the large number of degree of freedom. In this paper, a servovalve-piston combination system for a straight-line motion of robot leg is modeled as three degree of freedom based on double inputs and single output transfer function. The output is the displacement of piston from neutral. The inputs are valve displacement from neutral and arbitrary load force in this system. LQR(Linear Quadratic Regulator) technique is applied in order to achieve robust stability and fast responses of the system. The Kalman filter loop, rejection of disturbance and noise, riccati equation, filter gain matrix, and frequency domain equality are analyzed and designed.