• 제목/요약/키워드: 다중벽 탄소 나노튜브 나노유체

검색결과 17건 처리시간 0.019초

열교환기 표면상태와 CHF의 상관관계에 대한 연구 (A Study on the Relationship between Surface Condition and Critical Heat Flux in Heat Exchanger)

  • 김우중;김남진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권2호
    • /
    • pp.1-6
    • /
    • 2020
  • This work experimentally explored the influence of nano-fouling on CHF, flow boiling heat transfer coefficient, contact angle, and surface roughness. In this study, the flow velocity conditions are established at 0.5, 1.0, and 1.5 m/s. Also, the nanoparticles of oxidized MWCNT were deposited on a heat transfer surface for 0, 120, 180, and 240 sec. As the results, it was found that CHF and superheated temperature were increased in case of nano fouling on the heat transfer surface in oxidized MWCNT fluid. Also, the contact angle and surface roughness decreased when flow velocity and nano coating increased.

경계조건에 따른 다중벽 탄소나노튜브의 유체유발 불안정성 변화 (Flow-induced Instability of Multi-wall Carbon Nanotubes for Various Boundary Conditions)

  • 윤경재;송오섭
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.805-815
    • /
    • 2010
  • This paper studies the influence of internal moving fluid and flow-induced structural instability of multi-wall carbon nanotubes conveying fluid. Detailed results are demonstrated for the variation of natural frequencies with flow velocity, and the flow-induced divergence and flutter instability characteristics of multi-wall carbon nanotubes conveying fluid and modelled as a thin-walled beam are investigated. Effects of various boundary conditions, Van der Waals forces, and non-classical transverse shear and rotary inertia are incorporated in this study. The governing equations and three different boundary conditions are derived through Hamilton's principle. Numerical analysis is performed by using extended Galerkin's method which enables us to obtain more exact solutions compared with conventional Galerkin's method. This paper also presents the comparison between the characteristics of single-wall and multi-wall carbon nanotubes considering the effect of van der Waals forces. Variations of critical flow velocity for different boundary conditions of two-wall carbon nanotubes are investigated and pertinent conclusion is outlined.

PVP가 첨가된 탄소나노유체의 특성에 대한 연구 (Characteristics of Carbon Nano Fluid Added PVP)

  • 서향민;박성식;김남진
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.289-295
    • /
    • 2010
  • In this study, the enhancement of the thermal conductivity of water in the presence of multi-walled carbon nanotubes, MWCNT, was investigated. Sodium Dodecyl Sulfate, SDS, and Polyvinylpyrrolidone, PVP, were employed as the dispersant. SDS or PVP was added in pure water. And then, MWCNT of 0.0005, 0.001, 0.002, 0.003, 0.004, 0.005, 0.01, and 0.02 vol% was dispersed respectively. The thermal conductivity and the viscosity were measured with a transient hot-wire instrument built for this study and the DV II+ Pro viscometer. The results showed that PVP had good thermal conductivity at 300 wt% and this was better than that of SDS 100 wt%, also, the viscosity of nano fluid added PVP rapidly increased until 0.02 vol%.

물 기반 탄소나노튜브 나노유체 히트파이프의 열적 특성에 관한 실험적 해석 (Experimental Investigation on Thermal Characteristics of Heat Pipes Using Water-based MWCNT Nanofluids)

  • 하효준;공유찬;도규형;장석필
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.528-534
    • /
    • 2011
  • In this paper, thermal characteristics of cylindrical grooved wick heat pipes with water-based MWCNT nanofluids as working medium are experimentally investigated. Volume fractions of nanoparticles are varied with 0.1% to 0.5%. Transient hot wire method developed in house is used to measure the thermal conductivity of nanofluids. It is enhanced by up to 29% compared to that of DI water. The thermal resistances and temperature distributions at the surface of the heat pipes are measured at the same evaporation temperature. The experimental results show that the thermal resistance of the heat pipes with water-based MWCNT nanofluids as working fluid is reduced up to 35.2% compared with that of heat pipe using DI water. The reduction rate of thermal resistance is greater than the enhancement rate of thermal conductivity. Finally, based on the experimental results, we present the reduction of the thermal resistances of the heat pipes compared with conventional heat pipes cannot be explained by only the thermal conductivity of water-based MWCNT nanofluids.

히트파이프 작동유체 개발을 위한 에탄올-탄소나노튜브 나노유체의 열전도도 및 점도 특성 연구 (Study on the Thermal Conductivity and Viscosity of Ethanol with Carbon Nanotubes for the Development of a Heat Pipe Working Fluid)

  • 안응진;박성식;박윤철;김종윤;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.9-16
    • /
    • 2012
  • Nanofluids using Carbon Nanotubes have a excellent thermal characteristic. In this study, for increasing the efficiency of solar collector, the thermal conductivity and viscosity of Ethanol-Oxidized Multi-walled Carbon Nanofluids were measured. Nanofluids were manufactured by ultra-sonic dispersing Oxidized Multi-walled Carbon Nanotubes(OMWCNTs) in ethanol at the rates of 0.0005 ~ 0.1 vol%. The thermal conductivity and viscosity of manufactured nanofluids were measured at the low temperature($10^{\circ}C$), the room temperature($25^{\circ}C$) and the high temperature($70^{\circ}C$). For measuring thermal conductivity and viscosity, we used transient hot-wire method and rotational digital viscometer, respectively. As a result, under given temperature conditions, thermal conductivity of the 0.1 vol% nanofluids improved 33.74% ($10^{\circ}C$), 33.14% ($25^{\circ}C$) and 32.36% ($70^{\circ}C$), and its viscosity increased by 37.93% ($10^{\circ}C$), 31.92% ($25^{\circ}C$) and 29.42% ($70^{\circ}C$) than the base fluids.

순수 물과 에탄올 산화 탄소나노유체의 열전도도 및 점도 특성 비교 연구 (A Comparative Study on the Thermal Conductivities and Viscosities of the Pure Water and Ethanol Carbon Nanofluids)

  • 안응진;박성식;천원기;박윤철;전용한;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.213-219
    • /
    • 2012
  • Nanofluids are advanced concept fluid that solid particles of nanometer size are stably dispersed in fluid likes water, ethylene glycol and others. They have higher thermal conductivities than base fluids. If using this characteristic, efficiencies of heat exchangers can be increased. Therefore in this study, we measured thermal conductivity and viscosity of carbon nanofluids. They were made to ultra sonic dispersed oxidized multi-walled carbon nanotubes(OMWCNTs) in distilled water and ethanol, respectively. The mixture ratios of OMWCNTs were from 0.0005 vol% ~ 0.1 vol%. Thermal conductivity and viscosity was measured by transient hot-wire method and rotational viscometer. The results of an experiment are as in the following: thermal conductivity of the 0.1 vol% pure-water nanofluid improved 7.98% ($10^{\circ}C$), 8.34% ($25^{\circ}C$), and 9.14% ($70^{\circ}C$), and its viscosity increased by 37.08% ($10^{\circ}C$), 33.96% ($25^{\circ}C$) and 21.64% ($70^{\circ}C$) than the base fluids. Thermal conductivity of the 0.1 vol% ethanol nanofluids improved 33.72% ($10^{\circ}C$), 33.14% ($25^{\circ}C$), and 32.25% ($70^{\circ}C$), and its viscosity increased by 35.12% ($10^{\circ}C$), 32.01% ($25^{\circ}C$) and 19.12% ($70^{\circ}C$) than the base fluids.

태양열 집열기 적용을 위한 순수 물과 에탄올 탄소나노유체의 특성 비교 연구 (A Comparative Study on the Characteristics of the Pure water and Ethanol Carbon Nanofluids for Applying Solar Collector)

  • 안응진;박성식;천원기;박윤철;김남진
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.194-199
    • /
    • 2012
  • In this study, for increasing the efficiency of solar collector, the thermal conductivities and viscosities of the pure water and ethanol oxidized multi-walled carbon nanofluids were measured. Nanofluids were manufactured by ultra-sonic dispersing oxidized multi-walled carbon nanotubes(OMWCNTs) in the pure-water and ethanol at the rates of 0.0005 ~ 0.1 vol%. the Thermal conductivities and viscosities of manufactured nanofluids were measured at the low temperature($10^{\circ}C$), the room temperature($25^{\circ}C$) and the high temperature($70^{\circ}C$). For measuring thermal conductivity and viscosity, we used Transient Hot-wire Method and Rotational Digital Viscometer, respectively. As a result, under given temperature conditions, thermal conductivity of the 0.1 vol% pure-water nanofluid improved 7.98% ($10^{\circ}C$), 8.34% ($25^{\circ}C$), and 9.14% ($70^{\circ}C$), and its viscosity increased by 37.08% ($10^{\circ}C$), 33.96% ($25^{\circ}C$) and 21.64% ($70^{\circ}C$) than the base fluids. Thermal conductivity of the 0.1 vol% ethanol nanofluids improved 33.72% ($10^{\circ}C$), 33.14% ($25^{\circ}C$), and 32.36% ($70^{\circ}C$), and its viscosity increased by 37.93% ($10^{\circ}C$), 31.92% ($25^{\circ}C$) and 29.42% ($70^{\circ}C$) than the base fluids.

  • PDF