• Title/Summary/Keyword: 다수정

Search Result 690, Processing Time 0.034 seconds

Test Application of Electrical Conductivity Measurement in Borehole for Determining Aquifer Properties (대수층의 수리특성 연구를 위한 시추공 전기전도도 측정기법의 현장 시험 적용)

  • Kim Yeong-Hwa;Kim Ji-Hoon;Hong Jeong-Pyo
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • As a trial to find an efficient technique for determining hydraulic conductivity, a test application of electrical conductivity measurement technique was made using a signal conditioning data acquisition system in borehole. The experiment was made in two test boreholes BM-2 and BM-3 which are located in the Experiment forests of Kangwon National University in Bongmyongri, Chunchon. We obtained series of electric conductivity variation curves after the beginning and completion of saline water injection using these two bore-holes as the pumping well and the observing well alternatively, The analysis of time series electrical conductivity data suggests kinds of valuable information about aquifer properties by holes and depths, and we could confirm the potential of this method as an efficient tool for in situ aquifer test.

A Preliminary Design for Hybrid Building System with Progressive Collapse Prevention Means (연속붕괴가 방지된 초고층 복합빌딩시스템의 예비설계)

  • Choi, Ki-Bong;Cho, Tae-Jun;Kim, Seong-Soo;Lee, Jin-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.48-54
    • /
    • 2015
  • In this study, we propose an innovative lateral force distribution building system between tall buildings by utilizing the difference of moment of inertia, resulting the reduction of lateral displacement and the lateral forces in terms of an alternative for the dense human and increased cost of lands in highly integrated city area. A successive collapse prevention means by providing additional bearing plate between connections is proposed. In addition to that, a more economical vibration reduction is expected due to the suggested tuned mass damper on the surface of spacial structure. In the considered verification examples, reduced drifts at the top location of the building systems are validated against static wind pressure loads and static earthquake loads. The suggested hybrid building system will improve the safety and reliability of the new or existing building system in terms of more than 30% reduced drift and vibration through the development of convergence of tall buildings and spatial structures.

Design and Implementation of Malicious Application Detection System Using Event Aggregation on Android based Mobile Devices (안드로이드 모바일 단말에서의 이벤트 수집을 통한 악성 앱 탐지 시스템 설계 및 구현)

  • Ham, You Joung;Lee, Hyung-Woo
    • Journal of Internet Computing and Services
    • /
    • v.14 no.3
    • /
    • pp.35-46
    • /
    • 2013
  • As mobile terminal environment gets matured, the use of Android platform based mobile terminals has been growing high. Recently, the number of attacks by malicious application is also increasing as Android platform is vulnerable to private information leakage in nature. Most of these malicious applications are easily distributed to general users through open market or internet and an attacker inserts malicious code into malicious app which could be harmful tool to steal private data and banking data such as SMS, contacts list, and public key certificate to a remote server. To cope with these security threats more actively, it is necessary to develop countermeasure system that enables to detect security vulnerability existing in mobile device and take an appropriate action to protect the system against malicious attacks. In this sense, this paper aggregates diverse system events from multiple mobile devices and also implements a system to detect attacks by malicious application.

Connection Scheduling for Improving the Response Time (응답시간 향상을 위한 커넥션 스케줄링 기법)

  • Bang, Ji-Ho;Ha, Rhan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.1_2
    • /
    • pp.69-78
    • /
    • 2006
  • The client request scheduling techniques for web server can classified into the scheduling techniques considering a document size to be requested and not. The scheduling techniques considering a document site to be requested provides a better average response time than another As the size-based SRPT(Shortest Remaining Processing Time first) is typical, and the most of scheduling techniques considering a web document size are based on SRPT. Most of existing researches, however, have not considered the feature of HTTP/1.1 which enable the clients to request concurrent multiple inlined-contents in a HTML document via each connection. In this paper we propose a connection scheduling technique with the scheduling window which provides a better response time in HTTP/1.1. The experimental results show that the performance with the proposed approach is improved about $10\%$ more than the connection scheduling with SRPT.

Mitochondrial Distribution and Methionine Uptake in Fragmented and Non-fragmented Embryos Derived from Multi-pronuclei Zygotes in Human In Vitro Fertilization (IVF) Program (사람 다수정난자의 체외배양시 Fragmented Embryo와 Non-fragmented Embryo에서의 Methionine 유입량 및 미토콘드리아 분포양상의 비교)

  • Do, B.R.;Chung, M.K.;Chang, M.K.;Lee, K.A.;Ko, J.J.;Yoon, T.K.;Cha, K.Y.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.22 no.3
    • /
    • pp.279-285
    • /
    • 1995
  • Despite the frequent incidence of embryo fragmentation in early human embryos, the reason of the embryo fragmentation has not been known yet. This study was conducted to investigate the histological difference(s) between fragmented (FR) and non-fragmented (NFR) human embryos focusing on comparison of mitochondrial distribution and protein synthesis. Multi-pronuclei zygotes (MPZ) such as three or more pronuclei containing in human in vitro fertilization and embryo transfer (IVF-ET) program were used for this study. MPZ were cultured in TCM-199 supplemented with 10% of human fetal cord serum (hFCS) in 5% $CO_2$ incubator at $37^{\circ}C$ for 24 hours. The cleaved embryos to 2-4 cells after 24 hours were grouped by their grade of fragmentation. Embryos were stained with Rhodamine123 (Rh123) and fluorescence was evaluated under the fluorescence microscope through PB 450-490 filter (Leitz). Regarding to protein synthesis during early human embryogenesis, there is no significant difference in the amount of synthetic proteins between FR and NFR embryos. Distribution of cytoplasmic organelles in embryos was evaluated by transmission electron microscope (TEM). The cytoplasmic distribution of mitochondria was different between FR and NFR embryos. The mitochondrial distribution was even in NFR, whereas severely aggregated in FR. It is not able to clarify in the present study whether this uneven mitochondrial distribution in FR embryo is the reason for embryo fragmentation or is the result from fragmentation. Physiological disparity related to the mitochondrial distribution may be one of the reasons for embryo fragmentation. Further studies should be addressed to investigate the physiological differences between FR and NFR embryos.

  • PDF

A Mycosis of Unidentified Fungi in Olive Flounder (Paralichthys olivaceus) (넙치의 미동정 진균 기생증)

  • Kim, Wi-Sik;Baik, Keun Sik;Kim, Duwoon;Seo, Joong-Kyeong;Oh, Myung-Joo;Kang, So Young
    • Korean Journal of Ichthyology
    • /
    • v.27 no.4
    • /
    • pp.306-309
    • /
    • 2015
  • In 2014, high mortality was observed in olive flounder (Paralichthys olivaceus) during experimental infection. Diseased fish did not show any outward clinical signs, but numerous fungal hyphae were detected in the gills. No parasites or bacteria were isolated from the diseased fish. A high mortality rate (100%) resulted when cohabitation with fungi-infected fish were applied to healthy fish. The affected fish exhibited sever fungi infection in the gills. Histopathological examination revealed numerous fungal hyphae and mycelium around gill filament, lamellar and racker. These results suggest that the fungi may be related with the mortality of olive flounder.

Evaluation of University Library Efficiency Using Data Envelopment Analysis (DEA를 적용한 대학도서관의 효율성 평가)

  • Jung, Young-Mi
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.22 no.4
    • /
    • pp.301-315
    • /
    • 2011
  • DEA(Data Envelopment Analysis) is useful to measure the relative efficiency of organizational units where the presence of multiple inputs and outputs. This study applied DEA-CCR and DEA-BCC to evaluate the technical, pure technical, and scale efficiency of 29 university libraries. The input variables were number of books, print edition expenses, building space, staff, number of seats. As output variables we estimated: reader visits, number of borrowed items, number of visitors. It was found out that number of libraries with 100% relative efficiency among 29 libraries were 13. Also the results shows that main reason of inefficiency was from scale rather than from pure technical. Many inefficient libraries were operations of increasing return to scale.

Bond between Reinforcing Bars and Recycled Coarse Aggregate Concrete with respect to Reinforcement Location (철근의 위치에 따른 이형철근과 순환굵은골재 콘크리트의 부착특성)

  • Yun, Hyun-Do;Lee, Min-Jung;Jang, Yong-Heon;Bae, Kee-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1093-1096
    • /
    • 2008
  • This study investigated the bond behavior between recycled coarse aggregate (RCA) concrete and deformed reinforcing bars. The position (i.e., vertical, horizontal) and the location (i.e., 375mm, 225mm and 75 mm) of deformed bar were considered as a main test parameter in this paper. From the test results, it was found that maximum bond strength of top reinforcement was decreased compared with that of bottom reinforcement. Also bar embedded horizontally 225mm above from base could not satisfy bond strength requirement provided in CEB-FIP code. It was caused by the fact that bonded area at the bottom of horizontal reinforcement was significantly reduced by the poring water and laitance. In this specimen, the bond strength provided by bearing stress and wedging action of concrete was not fully observed.

  • PDF

Behavior of concrete cylinders confined by jacketing with lateral confining stress (횡방향 구속응력에 의한 자켓팅-콘크리트 공시편 거동)

  • Cho, Sung-Chul;Choi, Eun-Soo;Chung, Young-Soo;Cho, Baik-Soon;Choi, Ji-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.157-160
    • /
    • 2008
  • The confined concrete subjected multi-axil stresses have been known as the strength of concrete increases significantly. Many researchers have studied in confining effect of concrete, and now are studying in many fields. Lap splices were located in the plastic hinge region of most bridge piers that were constructed before the adoption of the seismic design provision of Korea Highway Design Specification on 1992. But sudden brittle failure of lap splices may occur under loading. This study introduces a new method to retrofit RC bridge columns with lap splice which do not have enough ductility during an earthquake. The new method use mechanical external pressure and steel plates around RC columns. The jacketing built following the new method shows good results of increasing the compressive strength and ductility of concrete cylinders. The thicker steel jacket shows larger compressive strength, however, the ductility at failure depends on the welding quality of steel jackets. In this study, The effect of the new method is verified through comparing the results of the compressive tests and analysis results.

  • PDF

A Low Power Parking Management System for Intelligent Building (인텔리전트 빌딩을 위한 저 전력 주차관리 시스템)

  • Lee, Chang-Ki;Im, Hyung-Kyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1479-1485
    • /
    • 2012
  • The parking management system can increase driver's convenience with detailed parking information service in the parking lot. At the same time, parking management system consumes non-negligible electrical energy with large amount of sensors, displays and control modules. With the increase in the demand for green and sustainable building design all over the world, it becomes a meaningful issue for parking management system to reduce operating power. This paper presents the preliminary design and estimated results of a parking management system which is optimized to reduce the power consumption mainly on detectors and displays. The system design is based on pre-developed wireless parking detectors, Park Tile and Park Disk. The system has a number of parking space detectors, vehicle count detectors, information displays, guidance terminals and other control units. We have performed system architecture design, communication network design, parking information service scenario planning, battery life regulation and at last operating power estimation. The estimated operating power was 0.93KW per parking-slot, which is 20% of traditional systems. The estimated annual maintenance cost was 18% of traditional systems.