• Title/Summary/Keyword: 다량치환

Search Result 162, Processing Time 0.026 seconds

Compressive Strength Properties of Steam-cured High Volume GGBFS Cement Concrete (증기양생한 고로슬래그 다량치환 시멘트 콘크리트의 압축강도 특성)

  • Hong, Seong-Hyun;Kim, Hyung-Suk;Choi, Seul-Woo;Lee, Kwang-Myong;Choi, Se-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Recently, lots of researches on concrete with high volume mineral admixture such as ground granulated blast furnace slag (GGBFS) have been carried out to reduce $CO_2$. It is known that the precast concrete has an advantage of high strength at early age due to steam curing, even if concrete has high replacement level of mineral admixture. However it demands the investigation of compressive strength properties according to steam curing regimens. In this study, concretes with water-binder ratio of 32, 35% and water content of 135, 150, $165kg/m^3$ were produced to investigate compressive strength properties of high volume (60% by mass) GGBFS cement concrete according to steam curing regimens. Then steam curing was implemented with the maximum temperature of 50, $60^{\circ}C$ and steaming time of 5, 6, 7 hours. From the test results, it was found that steam curing was effective to raise early strength of high volume GGBFS cement concrete, but 28 day compressive strengths of steam cured specimens were lower than those of water cured specimens. Thus, a further study would be needed for the optimum steam curing regimens to satisfy target demolded strength and specified strength for the application of high volume GGBFS cement concrete to precast concrete members.

Effects of Micropores on the Freezing-Thawing Resistance of High Volume Slag Concrete (슬래그를 다량 치환한 콘크리트의 동결융해 저항성능에 미치는 미세공극의 영향)

  • Kim, Rae-Hwan;Kim, Gyu-Yong;Lee, Bo-Kyeong;Shin, Kyoung-Su;Song, Gwon-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, effects of micropores on the freezing-thawing resistance of high volume slag concrete are reviewed. Concrete was made with slag which contains the ground granulated blast furnace slag(GGBS) and the pig iron preliminary treatment slag(PS) by replacing 0, 40, 70 %, then compressive strength, freezing-thawing resistance, micropores were reviewed. Also, specified design strength, target air contents were set. Deterioration was induced by using 14-day-age specimen which has low compressive strength for evaluating deterioration by freeze-thawing action. As results of the experiment, despite of specified design strength which has been set similarly and ensured target air contents, the pore size distribution of the concrete showed different results. Micropores in GGBS70 specimen have small amount of water which is likely to freeze because there is small amount of pore volume of 10~100 nm size at 0 cycle which has not been influenced by freezing-thawing. For these reasons, it was confirmed that the freezing-thawing resistance performance of GGBS70 is significantly superior than other specimens because relatively small expansion pressure is generated compared to the other specimens.

The Application of High Volume Fly-Ash Concrete on Construction Site (플라이애쉬 다량 치환 콘크리트 현장 적용)

  • Park, Chan-Kyu;Lee, Hoi-Keun;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.271-272
    • /
    • 2009
  • In this study, the application results of high volume fly ash concrete(HVFAC) on the construction site were reported. The structures were the mat foundations of 3m and 2m thickness with design strength of 40MPa. The replacement ratio of fly ash was 50%, and the pre-mix type binder was used. As a result, it appeared that the temperature increases of concrete foundations were about $39^{\circ}$C for 3m thickness and $36^{\circ}$C for 2m thickness.

  • PDF

Effect of Waste Cooking Oil on Durability of High Volume Mineral Admixture Concrete (폐유지류가 혼화재 다량 치환 콘크리트의 내구성에 미치는 영향)

  • Han, Min-Cheol;Woo, Dae-Hoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.173-180
    • /
    • 2013
  • This paper is to investigate an effect of waste cooking oil(WCO) on the engineering properties and durability of high volume admixture concrete. Fly ash with 30% and blast furnace slag with 60% were incorporated in OPC to fabricate high volume admixture concrete with 0.5 of W/B. Emulsified refining cooking oil(ERCO) was made by mixing WCO and emulsifying agent to improve fluidity. ERCO was replaced by cement from 0.25 to 1.0%. As results, the increase of ERCO resulted in decrease of slump and air contents. For compressive strength, the use of ERCO led to decrease the compressive strength at 28 days, while it had similar strength or much higher strength than plain concrete at 180 days. Resistance to carbonation and chloride penetration was improved with the increase of ERCO contents due to decreased pore distribution by saponification between ERCO and concrete, while freeze-thaw resistance was degraded due to air loss.

Strength Properties by Curing Temperature of High Volume Fly-Ash Concrete (플라이애쉬를 다량 치환한 콘크리트의 양생온도에 따른 강도성상)

  • 이동하;정근호;백민수;김성식;임남기;정상진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.63-66
    • /
    • 2002
  • In this study, it does a high volume flyash substituted concrete experiments in two curing temperature circumstances - 35$^{\circ}C$, 2$0^{\circ}C$. High volume flyash concrete is tested in fresh concrete properties and hardeded concrete properties. In the fresh concrete test items, there is slump, air contents, concrete setting tests. 3, 7, and 28 days water curing compressive strength is measured in the hardened concrete test. The purpose of this study is to submit a various flyash concrete data for application to field. The result of this study is that the best strength is developed at the plain concrete cured 2$0^{\circ}C$ and Mixing F43 shows the best strength among specimens which cured at 35$^{\circ}C$

  • PDF

Mechanical Properties of Concrete Containing Blast Furnace Slag according to CBS Dust Replacement Ratio (CBS Dust 치환율에 따른 고로슬래그 다량치환 콘크리트의 역학적 특성)

  • Sin, Se-Jun;Han, Jun-Hui;Lee, Young-Jun;Lee, Dong-Joo;Lee, Jun-Seok;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.38-39
    • /
    • 2019
  • Mechanical properties of concrete containing furnace slag according to the CBS Dust Replacement Ratio were analyzed. The experimental study found that the compressive strength was excellent in the early age when the CBS Dust was replaced, and the drying shrinkage was excellent, and the replacement of CBS Dust 5% on the concrete containing the furnace slag would have a positive effect.

  • PDF

Effect of Micro Bubble on the High-Voiume Slag Concrete Mixed with Emulsified Refined Cooking Oil (마이크로버블이 유화처리 정제유지류(ERCO)혼입 고로슬래그 다량 치환 콘크리트의 특성에 미치는 영향)

  • Kim, Min-Yoyng;Park, Young-Jun;Baek, Doo-Hwan;Baek, Byung-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.44-45
    • /
    • 2015
  • Although the carbonation problem of high-volume slag concrete has been solved by the mixed use of emulsified refine cooling oil as the pilot study, there was an instance of securing air quantity and frost resistance followed by the use of Expancel due to the problem of having vulnerability in frost resistance in result as the air quantity has not been secured. But due to the problem of Expancel not being economical, air quantity and frost resistance of high-volume slag concrete mixed with ERCO are attempted to be secured using micro bubble that can remain in the water for a long time as a relatively economical and very microscopic bubble.

  • PDF

Simulation of Magneto-optic characteristic of One Dimensional Magneto-Photonic Crystal with an Active Layer of a Highly Bi-Substituted Iron Garnet (Bi가 다량 치환된 가네트 박막을 이용한 1차원 자성 포토닉 결정의 자기광학 특성의 시뮬레이션)

  • 류선열;박재혁;이종백;조재경
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.184-185
    • /
    • 2000
  • 1 차원 자성 포토닉 결정은 원하는 파장에서 큰 페러데이 회전각과 투과율을 얻을 수 있기에 아주 흥미롭다. 두 종류의 유전체 층(S: $SiO_2$, T:T $a_2$ $O_{5}$)을 주기적으로 적층한 구조에, Bi를 다량 치환한 가네트 박막(M:B $i_{1.07}$ $Y_{1.93}$F $e_{5}$ $O_{12}$)을 결함층으로 삽입한 (A/B)$_{k}$ M/(B/A)$_{k}$ 의 구조를 갖는 1차원 자성 포토닉 결정의 자기 광학 특성을 수치해석하였다. 가시광과 적외선 영역에서 1차원 자성 포토닉 결정의 자성체 층의 두께( $d_{M}$ )와 유전체 층의 적층수(k)를 변화시키며, 투과율(T)과 페러데이 회전각($ heta$$_{F}$ ) 및 성능지수(Q)를 조사하였다. (중략). (중략)(중략)

  • PDF

The Mechanical Properties of Concrete Usinga Large Amount of Fly Ash for Replacement Method (치환방법에 따른 플라이애쉬를 다량 치환한 콘크리트의 공학적 특성)

  • Kim, Tae-Wan;Kim, Tae-Sik;Jin, Chi-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.105-113
    • /
    • 2006
  • This paper presents the results of an experimental investigation carried out to evaluate the mechanical properties of concrete mixtures in which fine(S) and coarse(G) aggregate was fully replaced with fly ash(FA). And flowability reduction problem in a large amount of fly ash concrete settled addition water($W_f$) in concrete mixture. In the test, water-cement ratio($W_c/C$) was 0.35, 0.45, and water-fly ash ratio($W_f/FA$) was 0.35, 0.45. The fly ash replacement is two different method of P and Q. The P method is mix property that the fly ash and addition water($W_f$) weight is equal to the aggregate weight [ $FA+W_f$ = G (or S)]. The Q method is mix property that fly ash is equal to aggregate weight, and added addition water($W_f$) [$FA+W_f$ > G (or S)]. Test were performed for properties of fresh concrete and compressive strength were determined at 3, 7, 28 and 91 days. The result, compressive strength was improvement that $W_c/C=0.35$, $W_f/FA=0.35$ and fine aggregate replacement in P method series than others. The flowability at Q method was improvement result than P method, but compressive strength was not. Test results indicate significant improvement in the strength properties and flowability of plain concrete by the inclusion of fly ash as fully replacement of fine and coarse aggregate, and can be effectively the fly ash replacement method.

Quality Improvement of High Volume Fly Ash Concrete due to Early Strength Gain Admixture (조강형 혼화제에 의한 플라이애시 다량 치환 콘크리트의 품질 향상)

  • Han, Cheon-Goo;Park, Jong-Ho;Lee, Joung-Ah
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.117-124
    • /
    • 2009
  • The purpose of the study was to improve quality of high volume fly ash concrete. The study evaluated on the possibility of early quality improvement of high volume fly ash concrete with early strength gain admixture ('GA' below) developed by the preceding research. The study regarded applying naphthalene admixture ('NA' below) to mix proportion substituting FA 15 % to be plain. In the event of substituting FA 20, 25 and 30 %, the study compared engineering properties of concrete with plain by applying GA. Because of features of fresh concrete, fluidity falls down when GA is applied. Therefore, its use amount shall be increased. Only, in W/B 60 %, it was beneficial since slump loss was reduced about 35~70 mm than plain. The study could see that AE use should be increased proportionally since air content was reduced by coming from AE absorption operation of unburned coal content included in FA according to an increase in the amount of FA use. Reduction effect of bleeding could be anticipated since the amount of bleeding appeared at least in FA 20 %. Because of hardened concrete, time of setting appeared in the same level as plain when GA was applied. Therefore, it is judged that delay of setting can be reduced. In compressive strength, the study could check the same strength development as plain when GA was applied, having nothing to do with W/B and curing temperature. However, it is thought that we shall pay attention to GA use in the event of FA 30 % substitution. Freezing and melting resistance had less early value than plain. However, it is judged that there will be no problem of frost resistance since there is no a large difference between freezing and melting resistance and plain in overall. In accelerated neutralization, it was analyzed that a problem of weakening in neutralization appointed as a demerit when FA was applied in mass in proportion with GA use could be settled to some extent.

  • PDF