• Title/Summary/Keyword: 니들

Search Result 133, Processing Time 0.024 seconds

A Study on the Category and Classification System of Lace (레이스의 범주와 분류체계에 관한 연구)

  • Kim, Hee-Sun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.4
    • /
    • pp.117-136
    • /
    • 2014
  • The purpose of this study is to present a classification system of the hand-made and machine-made lace according to the configuration method and re-make the category and definition of lace to consider the emergence and development of major laces techniques. The re-made category and definition of the lace is as follows. The lace usually consists of ground and motifs, however, the techniques of netting and sprang are suitable for making ground than motif, so I think it is appropriate to exclude them from the category of the lace. Many scholars are excluded openwork embroidery fabric from the category of the lace. But, an openwork embroidery fabric is the basis of a needle point lace called true lace and is consist of motif and ground. I think it is appropriate to include it in the category of the lace. I think it is also appropriate to include in the category of the lace that the eyelet embroidery fabric which mimics the openwork embroidery fabric in the machine. Lace is redefined that a fabric with openwork decoration consists of motif and ground, constructed by a variety of ways such as plaiting, twisting, looping, knotting of threads or embroidering by hand or machine. The classification of the lace is presented as follows. Hand-made lace is classified bobbin lace, needle point lace, embroidery lace, knotted lace, crochet lace, and knitting lace. Machine-made lace is classified raschel lace, leaver lace, torchon lace, and machine-made embroidery laces which include tool lace, eyelet embroidery lace, chemical lace, etc.

  • PDF

Assessment of Resistance to Application Environment of Geotextile Composites (복합형 지오텍스타일의 적용환경에 대한 저항성 평가)

  • Jeon, Han-Yong;Lyoo, Won-Seok;Ghim, Han-Do;Chung, Chin-Gyo;Cho, Bong-Gyun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.3
    • /
    • pp.25-38
    • /
    • 2003
  • Geotextile composites to improve the resistance to the application environment were manufactured of recycled polyester geotextile with carbon black as ultraviolet stabilizer and polypropylene geotextile by needle-punching method. Mechanical properties, ultraviolet resistance and chemical stability were evaluated. Retention ratio of tensile properties of polypropylene geotextiles were decreased about 50% with the exposed condition by ultraviolet but those of geotextile composites showed the slightly decrease. Geotextile composites which have larger weights of recycled polyester geotextile were more stable against ultraviolet. For chemical stability, the changes of tensile strength values of geotextile composites were in the range of -20~+10% at the various chemical conditions.

  • PDF

Fabrication of Anti-Moiré Filter Using Multi-Array Needle Coating for LED Screens (다중 배열 니들 코팅을 이용한 LED 스크린용 Anti-Moiré 필터 제작)

  • Jeon, Kyungjun;Lee, Jinyoung;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.77-82
    • /
    • 2021
  • Using a multi-array needle module developed for coating of high-density cylindrical microlens array (C-MLA), we have fabricated an anti-Moiré filter for LED screens. The Moiré phenomenon appears due to the interference between the array pattern of image sensors in a camera and the non-emission area (grid pattern) of a LED screen. To suppress it, we have employed poly(methyl methacrylate) (PMMA) and coated it on a glass substrate in the form of a grid and non-grid (parallel lines). We have rotated the needle module in order to increase the number of C-MLAs. With this scheme, we have fabricated the 150 mm × 150 mm anti-Moiré filters where 836 microlens lines are formed. They show the average width of 255.4 ㎛, the average distance between CMLs of 94.6 ㎛, and C-MLA width non-uniformity of 4.7%. We have shown that the Moiré patterns still appear in the presence of the parallel (non-grid)-type filter, whereas they disappeared completely by the grid-type filter. It is due to the fact that the Moiré patterns are diffused more effectively by the grid-type C-MLA.

Fabrication of Spherical Microlens Array Using Needle Coating for Light Extraction of OLEDs (니들 코팅을 이용한 OLED 광 추출용 구형 마이크로렌즈 어레이 제작)

  • Kim, Juan;Shin, Youngkyun;Kim, Gieun;Hong, Songeun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.25-31
    • /
    • 2022
  • By an aid of needle coating, we have fabricated a spherical microlens array using poly(methyl methacrylate) for potential applications in light extraction of organic light-emitting diodes. With an attempt to achieve high-density and high-aspect-ratio microlens arrays, we have investigated the coating behaviors by varying the material parameters such as the solute concentration and wettability of the poly(methyl methacrylate) solution and process parameters such as the dwell time of needle near the substrate, retract distance of needle from the substrate, and coating gap between the needle and substrate. Under the optimized coating conditions, it is demonstrated that high-aspect-ratio microlens arrays can be obtained using a coating solution with high solute concentration and a small amount of a hydrophobic solvent. It is found that the diameter and height of microlens array are decreased with increasing poly(methyl methacrylate) concentration, yet the overall aspect ratio is rather enhanced. By the addition of 5 wt% hexylamine in 35 wt% poly(methyl methacrylate) solution, we have achieved a spherical microlens with the height of 7.7 ㎛ and the width of 94.24 ㎛ (the aspect ratio of 0.082). To estimate the capability of light extraction by the microlens array, we have performed ray tracing simulations and demonstrated that the light extraction efficiency of organic light-emitting diode is expected to be enhanced up to 24%.

Recent Advances in 3D/4D Printed Electronics and Biomedical Applications (3D/4D 프린트된 전자기기 및 바이오메디컬 응용기술의 최근 발전)

  • Hyojun Lee;Daehoon Han
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.1-7
    • /
    • 2023
  • The ability of 3D/4D printing technology to create arbitrary 3D structures provides a greater degree of freedom in the design of printed structures. This capability has influenced the field of electronics and biomedical applications by enabling the trends of device miniaturization, customization, and personalization. Here, the current state-of-the-art knowledge of 3D printed electronics and biomedical applications with the unique and unusual properties enabled by 3D/4D printing is reviewed. Specifically, the review encompasses emerging areas involving recyclable and degradable electronics, metamaterial-based pressure sensor, fully printed portable photodetector, biocompatible and high-strength teeth, bioinspired microneedle, and transformable tube array for 3D cell culture and histology.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

A Study on the Compression Moldability for Continuous Fiber-Reinforced Polymeric Composites -Part II : Effect of Correlation Coefficient on Compression Moldability- (연속섬유강화 플라스틱 복합재료의 압축성형성에 관한 연구 -제II보 : 압축성형성에 미치는 상관계수의 영향-)

  • 오영준;김이곤
    • Composites Research
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • During the compression molding process of the continuous fiber-reinforced polymeric composites, two main problems such as fiber-matrix separation and fiber orientation are produced by the difference of flow velocity. Molded parts are lead to be nonhomogeneous and anisotropic. As the mechanical property of the products are dependent on the separation and orientation, it is important to research the fiber mat structure and molding condition. If the fiber mat structure is changed by the increment of needling, the separation decreases and after compression molding the orientation is easily aligned. As it were, the compression moldability is good. But the defects as tears, thin thickness are produced in the products. Therefore, it is important to clarify the moldability in relation to the usage of products and the expenses of produce on the actual process. Therefore we must make the measurement methods that can define the moldability of products. In this research, the effects of the fiber mat structure(NP = 0, 5, 10, 25, 50 punches/$cm^2$) and the mold geometry($r_p$ = 1, 25, 50 mm) on the moldability of products were discussed. We investigated the case of one-dimensional flow in order to obtain the degree of nonhomogeneity and the fiber orientation function. In result, we could gain the correlation coefficient of the continuous fiber-reinforced polymeric composites. Also we experimented on the cup-type compression molding which was appeared the wrinkle on the flange part by the complex stress condition in order to gain the degree of nonhomogeneity and area ratio. In result, the moldability of products was expressed as the correlation coefficient and area ratio.

  • PDF

Surface treatment of polysaccharide by flexible active species generator (플렉서블 활성종 발생기를 이용한 다당류 표면처리)

  • Lee, Yu-Ri;Lee, Seung-Hun;Kim, Do-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.39-39
    • /
    • 2018
  • 최근 플라즈마 의학이 발달하면서 제트, 펜, 니들, 토치 등의 다양한 형태의 플라즈마 발생기가 개발되었으며 내부의 가스라인으로 가스의 종류, 유속, 조성 등을 조절하여 생물학적 효과를 극대화 할 수 있고 안정적으로 플라즈마 방전상태를 유지할 수 있으나 처리 면적이 좁아 실제 생물학적 시스템 (세포, 조직, 그리고 박테리아) 적용에 있어 한계점이 존재한다. 이러한 한계점을 극복하기 위해서 유전체격벽방전 (Dielectric barrier discharge, DBD) 방식을 이용한 플렉서블 활성종 발생기를 제작하고 생물학적 시스템에 적용하기 위한 방전 특성 평가를 진행하였으며, 간단한 in vitro 모델인 한천 젤을 이용하여 플라즈마 처리에 따른 전달물질의 침투거리를 확인하였다. 플라즈마 방전 시 생성되는 수산화기 [OH], 과산화수소 [$H_2O_2$], 초산소음이온 [$O_2{^-}$], 오존 [$O_3$], 그리고 산화질소 [$NO_x$]와 같은 산소 및 질소 활성종 (Reactive oxygen and nitrogen species, RONS)은 세포벽 또는 세포막의 주요 구성성분인 다당류와 인지질의 과산화 반응을 통해 구조를 변화시키고 생물학적 시스템의 표면의 pH를 낮춘다. 이러한 RONS의 작용은 살균, 소독 뿐만 아니라 약물의 침투를 돕는다. 일반적으로 한천 겔은 농도에 따라 생체 내 뇌 조직과 물리적 특성이 유사하고, 미생물학 기질, 방사선학 연구를 위한 조직모델로 사용되기 때문에 본 연구에서는 3%와 5% 농도의 한천 젤을 사용하여 침투거리를 확인하였다. 한천 젤은 $2.5{\times}2.5{\times}2.5cm^3$의 크기로 준비되었고 대조군으로 염료가 포함된 에멀젼을 0.01 g 도포하고, 실온에서 30분간 보존 후 단면을 잘라 현미경으로 침투거리를 확인하였으며, 실험군으로 플라즈마 전처리 후 에멀젼을 도포한 시표와 에멀젼 도포 후 플라즈마 처리한 시료에 대해 에멀젼 침투거리의 변화를 확인하였다. 본 연구의 플렉서블 활성종 발생기는 인체에 부착하여 사용되기 때문에 화상, 홍반을 유발을 방지하기위해 $40^{\circ}C$의 온도에서 실험을 진행하였고 이때에 플라즈마 방전조건은 $0.065W/cm^2$ 수준의 전력을 소모하는 1.7 kV의 전압, 16 kHz의 주파수로 10분간 처리하였다. 그 결과 3%의 한천 젤의 경우 침투거리 0.779 mm에서 0.826 mm, 0.942 mm까지 침투거리가 증가하였고 5%의 한천 젤의 경우 0.859 mm, 0.949 mm로 증가하였다. 이러한 침투거리 증가는 젤 표면의 다당류를 구성하고 있는 단량체가 플라즈마 처리시 화확적 구조가 끊어져 결론적으로 약물 침투가 증가된 것으로 판단된다.

  • PDF

Survey of Knowledge on Hypertension among the Parents of Elementary School Students (초등학생 학부모의 고혈압 관련 지식에 관한 조사)

  • Kim, Jin-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.1
    • /
    • pp.29-38
    • /
    • 2005
  • Objectives: Hypertension is the most important risk factors for the cerebrovascular diseases, and also for coronary heart diseases, it is therefore very important that the people have a knowledge on nature of hypertension and it's high risk in order to prevent and detect the hypertension as early as possible. Methods: This study was done to find out the knowledge on hypertension of 434 parents of elementary school students from Kimjae city, Jonbuk province, they were parents in grade 4, 5 and 6 attending two elementary schools. The survey took 10 days from November 20 to November 30, 2003. Results: first, The highest correct answer(94.5%) was "obesity is risk factors for hypertension", followed by "hypertension is closely related with hereditary factors(91.0%) and "high sodium intake is associated with high blood pressure"(85.7%). The lowest correct answer(77.4%) was the classification of blood pressure level between normal and high. Second, Rate of blood pressure measurement for fathers was 53.7% and 54.8% in mothers. Awareness of own blood pressure by fathers was 84.1 %, while 91.1% by mothers. Third, According to blood pressure level reported by parents, fathers with normal blood pressure was 59.2%, high normal blood pressure was 12.2%, while hypertension was 28.6%. It revealed that prevalence of hypertension of fathers was higher than mother (normal: 74.5%, high normal: 7.7%, hypertension: 18.2%). Conclusions: From the results of this study, it is important to strengthen the health education about hypertension for community people and also school students.

  • PDF

A Study on the Droplet Formation of Liquid Metal in Water-Mercury System as a Surrogate of Molten Salt-Liquid Metal System at Room Temperature (용융염-액체금속 계의 대용물인 물-수은 계에서 액체금속 액적의 생성에 대한 연구)

  • Kim, Yong-il;Park, Byung Gi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.165-172
    • /
    • 2018
  • As an approach for estimation of the droplet size in the molten salt-liquid metal extraction process, a droplet formation experiment at room temperature was conducted to evaluate the applicability of the Scheele-Meister model with water-mercury system as a surrogate that is similar to the molten salt-liquid metal system. In the experiment, droplets were formed through the nozzle and the droplet size was measured using a digital camera and image analysis software. As nozzles, commercially available needles with inner diameters (ID) of 0.018 cm and 0.025 cm and self-fabricated nozzles with 3-holes (ID: 0.0135 cm), 4-holes (ID: 0.0135 cm), and 2-holes (ID: 0.0148 cm) were used. The mercury penetration lengths in the nozzles were 1.3 cm for the needles and 0.5 cm for the self-fabricated nozzles. The droplets formed from each nozzle maintained stable spherical shape up to 20 cm below the nozzle. The droplet size measurements were within a 10% error range when compared to the Scheele-Meister model estimates. The experimental results show that the Scheele-Meister model for droplet size estimation can be applied to nozzles that stably form droplets in a water-mercury system.