• Title/Summary/Keyword: 능동형필터

Search Result 187, Processing Time 0.027 seconds

Active optical coupler using the side polished single mode fiber and thermo-optic polymer multimode planar waveguide (측면 연마된 단일모드 광섬유와 열 광학 다중모드 평면도파로를 이용한 능동형 광 결합기)

  • 김광택;유호종;김성국;이소영;송재원;이상재;김시홍;강신원
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.248-253
    • /
    • 1999
  • In this paper, we have investigated a fiber type active coupler which utilizes the mode coupling between the side polished single mode optical fiber and the active multimode planar waveguide. The proposed device can be used for not only tunable wavelength filter or optical intensity modulator but also a tool for measuring optical properties of guiding material such as refractive index, birefringence, electro-optic coefficient, and thermo-optic coefficient. We gave designed and optimized a coupler structure using the BPM and fabricated the device using thermo-optic polymer as active planar waveguide overlay. The device showed that insertion loss was less then 0.5 dB, extinction ratio was -13 dB at the resonance wavelength, and the wavelength tunablity due to thermo-optic effect was -1.5 nm/$^{\circ}C$. The active coupler using thermo-optic effect can be used as a wavelength tunable filer, an optical intensity modulator and an optical sensor. pulses that are subsequently compressed by a dispersive optical fiber. Experimental results show that $sech^2$ shape pulses with a pulse width of ~14 ps and a time bandwidth product of ~0.34 are successfully generated at 10 GHz repetition rate. In contrast to other methods, such as higher order soliton compression, this approach does not depend on the optical power and thus shows promise for application to low-power lasers.

  • PDF

Study on Improvement of Target Tracking Performance for RASIT(RAdar of Surveillance for Intermediate Terrain) Using Active Kalman filter (능동형 Kalman filter를 이용한 지상감시레이더의 표적탐지능력 향상에 관한 연구)

  • Myung, Sun-Yang;Chun, Soon-Yong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.52-58
    • /
    • 2009
  • If a moving target has a linear characteristics, the Kalman filter can estimate relatively accurate the location of a target, but this performance depends on how the dynamic status characteristics of the target is accurately modeled. In many practical problems of tracking a maneuvering target, a simple kinematic model can fairly accurately describe the target dynamics for a wide class of maneuvers. However, since the target can exhibit a wide range of dynamic characteristics, no fixed SKF(Simple Kalman filter) can be matched to estimate, to the required accuracy, the states of the target for every specific maneuver. In this paper, a new AKF(Active Kalman filter) is proposed to solve this problem The process noise covariance level of the Kalman filter is adjusted at each time step according to the study result which uses the neural network algorithm. It is demonstrated by means of a computer simulation that the tracking capability of the proposed AKF(Active Kalman filter) is better than that of the SKF(Simple Kalman Filter).

A Double Loop Control Model Using Leaky Delay LMS Algorithm for Active Noise Control (능동소음제어를 위한 망각형 지연 LMS 알고리듬을 이용한 이중루프제어 모델)

  • Kwon, Ki-Ryong;Park, Nam-Chun;Lee, Kuhn-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.28-36
    • /
    • 1995
  • In this paper, a double loop control model using leaky delay LMS algorithm are proposed for active noise control. The proposed double loop control model estimates the loudspeaker characteristic and the error path transfer function with on-line using only gain and acoustic time delay to reduce computation burden. The control of error signal through double loop control scheme makes the more robust cntrol system. The input signal of filter to estimate acoustic time delay is used difference between input signal of input microphone and adaptive filter output. And also, in nonstationary environments, the leaky delay LMS algorithm is employed to counteract parameter drift of delay LMS algorithm. For practical noise signal, the proposed double loop control model reduces noise level about 12.9 dB.

  • PDF

The Reverberation cancellation by using escalator algorithm in active sonar systems (능동 소오나 환경에서 에스컬레이터 알고리즘을 이용한 잔향음 제거)

  • 김수언;박경주;유경렬
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.779-782
    • /
    • 2000
  • 능동 소오나 시스템에서는 잔향음 제한 환경에서 표적 검출을 하기가 용이하지 못하다. 본 논문에서는 고정된 노치 필터로 제거할 수 없는 시 불변성의 잔향음을 효과적으로 제거할 수 있는 방법을 제안하였다. 제안된 알고리즘은 기존의 적응형 잡음 제거기가 갖고 있는 단점을 보완하기 위하여, Gram-Schmidt 직교화과정을 전처리 기법으로 사용하였다. 아울러, 제안된 잔향음 기법을 동해에서 실측한 자료에 적용함으로써 그 성능을 검증하였다.

  • PDF

Dynamic Passband Filter using Converging Wave in Volume Holographic Diffraction Grating (부피형 홀로그래픽 회절격자에서 수렴파를 이용한 능동 대역 필터)

  • An, Jun-Won;Nam, Ki-Won;Kim, Nam;Lee, Kwon-Yeon;Nam, Sang-Sig
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.35-42
    • /
    • 2000
  • A new dynamic passband filter enable to control the bandwidth using converging readout beam in photorefractive diffraction grating with high-efficiency is proposed and experimentally demonstrated. In this proposed scheme, the 3dB passband of a volume grating in crystal is theoretically predicted and the experimental results are obtained in consistent with our derivation that the bandwidth is controlled from 0.35nm to 3.3nm at the center wavelength of 670. 1nm.

  • PDF

Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method (직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법)

  • 김진선;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.213-221
    • /
    • 2004
  • In recent years, since more and more diode rectifiers with smoothing dc capacitor are used in electronic equipments, household appliances and ac drives, harmonics generated by these loads have become a major issue. In addition, 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. This systems show excessive currents in the neutral. These neutral currents are fundamentally third harmonic, and their presence is tied to wiring failure, elevating of neutral potentials, transformer overheating, etc. In response to the concerns, this paper proposes a series active power filter scheme based on direct compensating voltage extraction method and the advantage of this control algorithm is direct extraction of compensation voltage reference without multiplying gain. Therefore, the calculation of the compensation voltage reference will becom much simpler than other control algorithm. To verify the effectiveness of the proposed algorithm, a prototype active power filter is built and some experiments are carried out.

Analysis of Reduction Effect of Inter-Floor Noise Using Active Noise Control (ANC) Technique (능동소음제어 기술을 이용한 층간소음 저감효과 분석)

  • Hojin, Kim;Joong-Kwan Kim;Junhwan Kim;Hyunsuk Kim;Hyuk Wee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.45-56
    • /
    • 2023
  • In this study, the application of ANC (Active Noise Control) technology to address inter-floor noise was explored. To achieve this, an ANC system was developed to manage the heavy impact sound within the frequency range of 40 to 500 Hz. The ANC system utilized an adaptive filter employing a feedforward approach based on the Fx-LMS algorithm. To set up the ANC system, a comprehensive analysis of various variables within the system was performed using computational simulations. This process enabled the identification of optimal filter settings and system configuration arrangements. In addition, the ANC system was implemented in the inter-floor noise test room at the Korea Conformity Laboratories (KCL). Through a certified standard testing procedure, it was confirmed that the ANC system led to a 4 dB reduction in inter-floor noise when the system was activated compared to when it was turned off. The results of this study indicate that the developed ANC system has an effect significant enough to elevate the rating criteria by one level for heavy impact sound.

Design of Active Damping Filter for Stability Improvement of Grid Connected Photovoltaic Inverter with LCL Filter (LCL 필터를 가지는 태양광 인버터의 안정도 향상을 위한 Active Damping Filter 설계)

  • Park, Kwon-Sik;Choi, Hee-Chang;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.364-365
    • /
    • 2018
  • 본 논문에서는 LCL 필터를 가지는 계통연계형 태양광 인버터의 필터에 의한 공진을 억제하는 기법을 제시하였다. 기존의 L 필터보다 LCL 필터가 높은 고조파 저감 효과를 가지지만 LC 필터가 추가됨으로써 발생하는 공진으로 인해 시스템은 불안정해진다. 공진을 억제하기 위해 댐핑 기법이 함께 사용된다. 능동 댐핑은 수동 댐핑에 비해 실제 저항이 추가되지 않음으로써 회로의 손실을 저감하는 장점이 있다. 적절한 설계 기법을 통해 공진을 억제하고 시스템의 안정성을 높였으며 시뮬레이션을 통해 제안한 방식의 타당성을 검증하였다.

  • PDF

Design of Analog Filter for Cellular Phone Using CMOS DDA (CMOS DDA를 이용한 무선 휴대폰 시스템용 아날로그 필터 설계)

  • 윤창훈;최석우;안정철
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.8
    • /
    • pp.12-18
    • /
    • 1998
  • 본 논문에서는 개선된 elliptic 저역통과 함수를 제시하고, CMOS DDA 소자 및 DDA 응용회로를 이용하여 CDMA 무선 휴대폰용 아날로그 DDA 저역통과 필터를 설계하 였다. 개선된 elliptic 저역통과 필터 함수는 통과대역과 저지대역에서 점진적 감소 파상 특 성을 갖고, 우수 또는 기수 차수 모두에 대해서 ω=0에서는 통과대역의 최대값, ω=∞에서 는 영이 된다. 또한 극점-Q 값이 감소함에 따라 주파수 및 시간영역의 특성 등이 기존의 함수와 비교하여 향상되었다. 아날로그 능동 저역통과 필터는 수동 복종단 제자형 회로망의 저감도 특성이 유지되는 개구리 도약법으로 모의하고, 적분기등을 외부 소자와의 정합이 필 요 없는 DDA를 이용하여 설계하였다. 설계된 DDA 회로의 단위 이득 주파수는 1.32GHz이 고 이를 이용하여 DDA 저역통과 필터를 설계하여 HSPICE로 시뮬레이션한 결과 필터의 차단 주파수는 630KHz로 설계명세조건과 일치하였다.

  • PDF

A Low-Cost 50kVA Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System (3상 4선식 전력계통에서 중성선 전류 제거를 위한 50kVA급 저가형 능동전력필터)

  • Jang M.S.;Choi S.W.;Kang C.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.734-739
    • /
    • 2003
  • 최근 상업용 빌딩, 주거용 빌딩 및 공장등의 저전압 3상 4선식 배전계통에서 PC, UPS, 정류기기, 조명장치 및 사무용기기등 비선형 부하의 사용이 증가하고 있으며, 이로 인한 과도한 중성선 전류는 중성선의 고장, 변압기의 과열 및 중성선과 접지사이의 전압강하등 심각한 문제를 야기시키고 있다. 본 논문에서는 3상 4선식 배전계통에서 중성선 전류 저감을 위한 새로운 능동전력필터를 제안한다. 제안한 방식은 제어가 간단하고 부하용량대비 인버터등 장치의 용량이 작아 저가격으로 실현할 수 있다. 제안한 시스템은 이론적인 분석과 모의실험 및 실험에 의하여 그 타당성을 입증한다.

  • PDF