• Title/Summary/Keyword: 눈의 불편감

Search Result 16, Processing Time 0.016 seconds

Measurement of Level of Stereoscopic Visual Fatigue for User Discomfort Improvement (사용자 불편함 개선을 위한 입체 영상 피로도 지수 측정)

  • Kim, Jong-Hak;Kim, Jueng-Hun;Ham, Hun-Ho;Cho, Jun-Dong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.20-24
    • /
    • 2011
  • As various 3D contents have been developed recently, number of users who use 3D glasses in the cinema or their house has increased. However, since a stereoscopic image causes visual fatigue, developers also advise children and pregnant against watching it for hours. In this paper, we proposed measurement of level of visual fatigue degree by analyzing histogram obtained from a disparity-map. We used binocular disparity approach which is a fundamental factor occurred by a stereoscopic image. This research can be used as an user discomfort improvement method by referring to a stereoscopic image producing and compensation. To obtain a disparity-map, our proposed method used a census algorithm which is suitable for real-time processing.

A study of Polarization Modulator to Single-cell type in Polarized Glasses 3D Display System Using Binocular Parallax

  • Kong, Kyung-Bae;Kwon, Jung-Jang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.71-78
    • /
    • 2019
  • Most 3D displays that are currently in the market adopt the binocular disparity method creating a different image for the left and right eye for a 3 dimensional effect. However, commercialized 3D image output devices lack in performance making it uncomfortable for the viewer and restrict the viewer to certain positions. In this paper, we propose a single-cell polarized lens type stereoscopic system which has a smaller viewing angle and reduced crosstalk, with improved light penetration compared to existing double-cell structures; and analyzed the single-cell polarized lens type stereoscopic system properties, and conducted an effect analysis of performance improvement compared to the dual-cell type. Results showed that the single-cell type had a 25% improved performance, and the 3D crosstalk index which is an important index for quality characteristics of stereoscopic systems, increased over about 37%, compared to the dual-cell type.

The differences of tear film for young Korean of a day indoor space (실내 공간 내에서 한국인 청년의 하루 중 눈물층 변화)

  • Oh, Hyun Jin;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.535-540
    • /
    • 2012
  • This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

Comparison of the Clinical Effect after Wearing Conventional and 2-Weeks Cosmetic Tinted Contact Lens (일반 미용 칼라 콘택트렌즈와 2주 교체용 미용 칼라 콘택트렌즈 착용에 따른 임상성능 비교)

  • Kim, Chang Jin;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2009
  • Purpose: To compare and analyze the ocular changes after wearing conventional and 2-weeks cosmetic tinted contact lens, which were made of different material and fabrication method. Methods: Thirty five university students, age of twenties, participated in this study. With daily wearing schedule, they had worn temporary cosmetic tinted lens for 2 weeks and conventional tinted lens for two month in their right and left eye, respectively. Subjective symptoms and objective signs were graded by using CCLRU scales and corneal thickness were measured after 1 day and 2 months wearing, and under or over 5 hours wearing in a day, respectively. Results: Major subjective symptoms found in the student wearing cosmetic tinted contact lens for a 1 day and 2 months were dryness, redness, foreign body sensation and itchiness. It was also found that those symptoms were more severe in left eye (conventional cosmetic tinted contact lens) than right eye (2-weeks cosmetic tinted contact lens). However, symptoms of redness in both eyes showed statistically significant difference in the case of 1 day and 2 months wearing and under or over 5 hours wearing in a day (p=0.000). After 2 months wearing, left eye with conventional cosmetic tinted contact lens showed limbal redness (p=0.000) and bulbar conjunctival redness (p=0.012) with statistically significance, whereas there was no significant difference in both eyes before lens wear. Left eye showed statistically significant changes in all objective signs, but right eye showed palpebral conjunctival redness, corneal staining and conjunctival staining. Therefore, it was concluded that conventional cosmetic tinted contact lens may be more effective on ocular changes after wearing of lens. A statistically significant changes in both eyes after wearing lens were found that corneal thickness increased about $5{\mu}m$ (p=0.001) in right eye whereas $7{\mu}m$ (p=0.004) in left eye. Conclusions: A statistically significant number of participants in this study preferred to wearing of high Dk/t temporary cosmetic tinted contact lens made by sandwich method which resulted in less ocular changes and may give more healthy and safe ocular conditions.

  • PDF

The Associated Factors with Xerostomia in Adults Aged 30 Years and Over (일부 만 30세 이상 성인에서 구강건조증 관련요인 분석)

  • Han, Hae-Seong;Kwon, Da-Ae;Kim, Ri-Na;Kim, Yu-Na;Lee, Gyeol-Hui;Lee, Na-Ram;Lee, Da-Jeong;Lee, Seung-Hui;Choi, Jun-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.1
    • /
    • pp.62-70
    • /
    • 2013
  • The aim of this study was to analyze factors related to xerostomia in adults aged 30 years and over. The data were analyzed using the t-test, one-way ANOVA and multiple linear regression analysis in the SPSS version 12.0 program. The results were as follow. 1. The respondents who were older than 51 years old, unemployed and had less than 3 million won of average monthly income were more aware of xerostomia (p<0.05). 2. The respondents who answered poor and moderate for their general and oral health and the group with duplicate medication and comorbidity were more aware of xerostomia (p<0.05). 3. The respondents that had problems in chewing, communication, ordinary activities and complained of pain discomfort and suffered from anxiety depression were more aware of xerostomia (p<0.001). 4. The respondents that answered frequent dryness on their skin, eyes, lips, and nasal mucosa were more aware of xerostomia (p<0.001). 5. Xerostomia showed highest correlation with quality of life ($\beta$=0.436) followed by the number of medications ($\beta$=0.239), sense of entire body dryness ($\beta$=0.200), feeling of hopelessness ($\beta$=0.160) and number of oral mucosa disease symptoms ($\beta$=0.099) (p<0.05). According to the results of the study, xerostomia may cause deterioration in quality of life. Thus, it is advised to improve the patient management system among dental professions to prevent various complications caused by xerostomia and conduct regular health education on the cause and management method of xerostomia.