• Title/Summary/Keyword: 누출음

Search Result 15, Processing Time 0.017 seconds

CWT-Based Method for Identifying the Location of the Impact Source in Buried Pipes (연속웨이브렛 변환을 이용한 충격음 위치 규명)

  • Kim, Eui-Youl;Kim, Min-Su;Lee, Sang-Kwon;Koh, Jae-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1555-1565
    • /
    • 2010
  • This paper presents a new method for indentifying the location of impact source in a buried duct. In a gas pipeline, the problem of leakage occurs due to the mechanical load exerted by construction equipment. Such leakage can cause catastrophic disasters in gas supply industries. Generally, the cross-correlation method has been used for indentifying the location of impact source in a pipeline. Since this method involves the use of the dispersive acoustic wave, it derives an amount of error in process of estimating the time delay between acoustic sensors. The object of this paper is to estimate the time delay in the arrival of the direct wave by using the wavelet transform instead of the dispersive wave. The wavelet transform based method gives more accurate estimates of the impact location than the cross-correlation method does. This method is successfully used to identify the location of impact force in an actual buried gas duct.

Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration (막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리)

  • Lee, Eun-Young;Kim, Hyung-Kuk;Giang, Luu Thi Thuy;Bae, Jae-Ho;Bae, Young-Shin;Won, Jong-Choul;Lee, Jae-Hoon;Park, Seung-Kyun;Cho, Yong-Wan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.997-1006
    • /
    • 2009
  • Organic removal efficiency and methane production rate, a feasibility of power generation from biogas, and the optimum conditions for membrane operation were evaluated for the pilot scale (5 tons/day) two-phase anaerobic digestion coupled with ultra filtration (TPADUF) system fed with garbage leachate. The TPADUF system is consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. When garbage leachate with 150 g/L of TCOD was fed to the TPADUF up to organic loading rate (OLR) of 11.1 g COD/L/d, the effluent TCOD was lower than 6 g/L and the average removal efficiencies of TCOD and SCOD were higher than 95%. The methane composition of the gas was 65%, and the methane yield was 39 $m^3/m^3$ garbage leachatefed, 260 $m^3$/tons $COD_{added}$, or 270 $m^3$/tons $COD_{removed}$, even there was some gas leak. The power production per consumed gas was 0.96 kWh/$m^3$ gas or 1.49 kWh/$m^3$ methane. This lower power production efficiency mainly due to the small capacity of gas engine (15 kW class). The membrane was operated at the average flux of 10 L/$m^2$/hr. When the flux decreased, washing with water and chemical (NaOCl) was conducted to restore the flux. In the TPADUF system, optimum pH could be maintained without alkali addition by recycling the membrane concentrate or mixed liquor of the methanogenic digester to the acidogenic reactor. Also, partial production of methane in the acidogenic reactor had a positive effect on lowering the OLR of the methanogenic reactor.

Evaluation of Groundwater Quality Characteristics around Uncontrolled Closed Valley Landfill (사용종료 비위생매립지 주변 지하수의 수질변화 특성)

  • Park, Joung-Ku;Kim, Tae-Dong;Choi, Dong Hyuk;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.3
    • /
    • pp.75-80
    • /
    • 2007
  • This study evaluated groundwater quality around an uncontrolled landfill in W sity, Korea, which was monitored for about two years (2005-2006). Parameters of concern include redox-sensitive indicators such as pH, DO, EC, ORP, DOC (dissolved organic carbon), NH3, NO3 and SO4. About 10 years have elapsed after closing dumping of municipal wastes in the landfill. Leachates showed widely varying concentrations in COD(136${\sim}$263 mg/L), T-N(121${\sim}$186 mg/L), and NH3-N(14${\sim}$369 mg/L). Groundwater at the immediate downgradient of the landfill showed weakly acidic pH condition but very high levels of EC (3,000-4,000 ${\mu}S/cm$), which indicated that the groundwater was largely affected by the landfill leachate. Cl, a conservative ion, showed over 200 mg/L at the landfill border, but a gradually decreasing level with distance from the landfill, representing dispersion and dilution (natural attenuation) due to mixing with surrounding groundwater and replenished rainwater. Redox potential showed negative value at the landfill border but it increased up to 350 mV at downgradient wells, which indicated conversion of redox condition from reducing oxic ones. Ammonia, was largely enriched at most of the monitoring wells and its level greatly exceeded drinking water standard. In summary, all the parameters evidenced occurrence of natural attenuation with distance and with time but further monitoring is still required.

Improvement of Atmospheric Dispersion Assessment for Accidental Releases Using a Fuzzy Logic Inference Method (퍼지 논리 추론 방법을 이용한 사고시 대기확산 평가 개선)

  • Na, Man-Gyun;Sim, Young-Rok;Kim, Soong-Pyung
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.19-26
    • /
    • 2001
  • In order to assess the atmospheric dispersion for the accidental releases of nuclear power plants, in calculating X/Q values in the XOQAR and PAVAN codes which are based on Reg. Guide 1.145, the X/Q and frequency values are plotted on log-normal paper. Starting with the highest X/Q value of this plot, the codes compare the slope of the line drawn from this point to every other point within an increment containing ten X/Q values. If there are fewer than ten values, only the number available are used. The coefficients that produce the line with the least negative slope are saved. The end point of this line is used as the next starting point, from which slopes to the points within the next increment, containing ten X/Q values, are compared. The X/Q values corresponding to the cumulative frequency values 0.5%, 5% or 50% are calculated to search for the $0{\sim}2$ hour X/Q value that tends to be a very conservative value. In this work, a fuzzy logic inference method is used for nonlinear interpolation of the X/Q values versus the cumulative frequency. The fuzzy logic inference method is known to be a food technique for nonlinear interpolation. The proposed method was applied to a potential accidential radioactive release of the Yonggwang nuclear power plant, which gives more realistic X/Q values.

  • PDF

Prosthetic rehabilitation by obturator considering the biomechanics in partially edentulous patient after maxillectomy (상악골 절제술을 받은 부분 무치악 환자에서 생역학을 고려해 제작한 구개 폐색장치를 이용한 보철 수복 증례)

  • Lee, Kang-Shin;Park, Ju-Mi;Ahn, Seung-Geun;Seo, Jae-Min;Park, Yeon-Hee;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.281-293
    • /
    • 2021
  • Patients who went through maxillectomy can have severely impaired swallowing, mastication, and pronunciation functions because of palatal defects. Leakage occurs through the nasal cavity while eating, chewing becomes difficult due to the loss of teeth and alveolar ridges, and oral and nasal passages are not separated, leading to hyper-nasal sound, and significantly reducing the quality of life. To prosthetically reconstruct the defect, the weight of the obturator should be reduced as much as possible to minimize dropout because of gravity, and the bulb of the obturator should be properly extended into the defect to get additional retention and stability. In this case of a partially edentulous patient who underwent additional maxillary resection because of tumor recurrence, a metal framework was designed by applying the basic design principles of removable partial dentures. An obturator with improved retention, stability, and support was fabricated through functional impressions. The patient was satisfied with the improved facial expression, mastication, swallowing, and pronunciation, and showed stable occlusion and oral hygiene management during the follow-up period.