• Title/Summary/Keyword: 누수저항

Search Result 80, Processing Time 0.03 seconds

Estimation of Reinforcement Effect of Superannuated Fill Dam Repaired by the Permeable Grouting Method (침투그라우팅이 시공된 노후필댐의 보수보강효과 평가)

  • Kim, Yungjin;Heo, Yol;Oh, Byunghyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.45-52
    • /
    • 2007
  • Maintenance of structural and hydrological safety of the superannuated fill dam is very important subject on the viewpoint of disaster prevention. Mainly, the core of the superannuated fill dams have been damaged continuously by the various harmful external forces such as the typhoons, flash floods and earthquake, and these can be connected to the large scaled general dam failure. Therefore, the research on the repair, remediation and reinforcement of dam is necessary. In this study, the permeable grouting method for the remediation of fill dam was examined by the electrical resistivity survey and the change of permeability of core front. As a result, the permeable grouting method can be useful remediation method for the superannuated fill dam, the leakage from the core front decreased greatly before and after the construction of grouting. Furthermore, it can be said that the turbidity of fill dam may not be greatly increased by grouting.

  • PDF

Modified Electrical Resistivity Survey and its Interpretation for Leakage Path Detection of Water Facilities (수변구조물의 누수 경로 탐지를 위한 변형된 전기비저항 탐사 및 자료 해석)

  • Lee, Bomi;Oh, Seokhoon
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.4
    • /
    • pp.200-211
    • /
    • 2016
  • To support cross potential array and direct potential array, the array for leakage detection of all kinds of water facilities is proposed and it is named as the D-Lux array. The D-Lux array data are arranged to a coloured matrix and it is called the D-Lux view. Low potential difference of anomalous zone shown in D-Lux view implies the indication of leakage zone. Furthermore, for an intuitive interpretation of D-Lux array, equipotential distribution map is made by using D-Lux and direct potential array data. Equipotential distribution map makes us possible to predict import point, export point and the path of water leakage that we could have not anticipated in D-Lux view and the graphs. The water tank experiment and numerical analysis were carried out as preparatory experiment and the field explorations were conducted at a concrete weir and a fill dam. As a result, effective and specific detection of leakage path was possible for the concrete weir and the fill dam.

A Study on the Performance Evaluation of Water(wash out) Resistance of 5-Type Repair Materials in Water Leakage of Underground Concrete Structures (지하 콘크리트 구조물 누수부위에 시공되는 5계열 보수재료의 유실 저항 성능 평가 연구)

  • Kim, Soo-Yeon;Yoo, Jae-Yong;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.61-68
    • /
    • 2020
  • In this study, the international standard ISO TS 16774 Part 3 Test Method for Water (wash out) Resistance and KS F 4935 「Sealant Injection type for water leakage maintenance of adhesive flexible rubber asphalt series」, which are standardized as a quality control method of injection type repair materials used for water leakage cracks in underground concrete structures, are currently used in Korea. As a result, considering the performance criteria of "mass change rate -0.1%" stipulated in KS F 4935, the remaining 13 types repair materials, excluding RG-2 of synthetic rubber and UG-1 of urethane, need to be reviewed for stabilization of the loss resistance due to the flow of ground water. The results of this study are determined to be available as a basic indicator for the selection of repair materials used for cracks in concrete structures. In addition, it is expected that the results of this study can be utilized as reference data that can be reflected in the improvement of the quality of repair materials that will be researched and developed later.

3D Resistivity Survey for Dam Safety Inspection (저수지 안전진단을 위한 3차원 전기비저항 탐사)

  • Cho, In-Ky;Yong, Hwan-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.99-106
    • /
    • 2019
  • Resistivity method has been used for the dam safety inspection and, for the convenience of fieldwork, two-dimensional (2D) resistivity data has been usually measured along the dam crest. However, since the dam has three-dimensional (3D) structure, 2D resistivity survey along the dam crest violates 2D assumption and 3D effects caused by 3D topography and material properties in the dam distort the inversion result of 2D resistivity data acquired along the dam crest. Furthermore, it is really hard to evaluate the 3D structure of the dam and 3D leakage pathway using 2D resistivity survey because 2D resistivity survey can provide only 2D resistivity section beneath the survey line. In this study, 3D resistivity survey was conducted at a dam in Korea. By comparing the results from 3D and 2D resistivity surveys, merit and demerits of 3D survey were investigated. Finally, it was confirmed that 3D survey can provide more accurate information about the dam status and 3D leakage pathway compared to the 2D survey. Therefore the 3D resistivity survey should be actively expanded for more accurate dam safety inspection even though more time and expense are required.

접착 테이프형 액체 누설 감지 박막 센서

  • Han, Guk-Hui;Kim, Yun-Jung;Jeong, Jong-Yun;Lee, Min-Gyeong;Gang, Han-Rim;Kim, Jung-Gil;Lee, Won-Yeong;Yu, Hong-Geun;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.355-355
    • /
    • 2012
  • 액체 누설을 감지하는 센서를 개발하였다. 이 센서는 경보 장치를 포함하며 접착 테이프형태의 박막 센서이다. 센서는 총 4개의 층으로 구성되어 있다. 각 층의 명칭은 접착제층, 베이스 필름층, 기판 필름층, 보호 필름층이다. 감지선의 사용량을 최소화하여 기판 필름층 위에는 총 4개의 선이 있다. 전도선 3개와 저항선 1개이다. 4개의 선들은 기판 필름층에 전도성 은나노 잉크를 그라비어인쇄기를 이용하여 센싱 회로를 인쇄하였으며 이 기술의 이 센서의 가장 큰 특징이다. 누수 발생 시에 저항선과 전도선에 액체가 접촉되어 회로 상에 교차하는 내부저항의 전압 변화를 모니터링하여 누수를 감지하는 방식의 센서이다. 감지선에 전원을 양방향으로 번갈아 인가함으로써 수분의 저항 값 증가 및 양극화를 방지하였다. 그로 인해 기존의 센서에 비해 좀 더 안정적이고 정확한 감지를 할 수 있다. 설치 후 센서가 마모되거나 손상될 시 간단하게 재설치 할 수 있다는 장점도 있다. 액체 누설 후에도 별도의 건조시간이 필요하지 않다. 표면에 남아있는 액체를 제거하여 즉시 재사용하는 것이 가능하다. 액체누설 감지 시스템은 액체누설 감지 필름 센서를 포함하며, 표시부와 경고음 발생부 등 전체를 제어한다. 표시부의 누설 위치 표시 단위는 미터(m)이며 최소 0.1 m 단위까지 표시한다. 이 액체누설 감지 시스템을 이용하여 누설 위치 감지 실험 및 액체별 누설 위치 감지 실험을 진행하였다.

  • PDF

A Study on the Change of Mass in Flow Velocity Using Loss Resistane Test Method - Using Synthetic rubber system Repair material - (유실저항성 시험방법을 이용한 유속조건에서의 질량변화 추이 연구 합성고무계 보수재료를 중심으로-)

  • Park, So-Young;Jang, Bo;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.127-128
    • /
    • 2017
  • Tests are conducted according to the ISO TS 16774, Part 3 standard for quality management of leakage repair materials used in cracks in underground concrete structures. These test methods are performed indirectly using a nonwoven fabric on a chalet containing leak repair materials. However, it is considered that it is appropriate to verify the resistance of the repair material, which is required to be applied directly to the cracks in the actual field and to exhibit the resistance of the flow velocity. In this study, mass change was measured by using nonwoven fabric and nonwoven fabric. As a result, both methods showed an increase in mass, which indicated that the maintenance material itself contained a large amount of water, and that the mass change occurred depending on the drying state. Also, depending on the use of nonwoven fabric, the error due to the indirect test could not be ruled out. Therefore, further verification is needed, and it is considered that the test for change of mass reduction measurement is necessary according to the drying time of other types of the same series.

  • PDF

Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment (방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용)

  • 송성호;이규상;김진호;권병두
    • Economic and Environmental Geology
    • /
    • v.33 no.5
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

A Study on the Estimation of Stability of Fill Dam by Long-term Electrical Resistivity Monitoring (장주기 전기비저항 모니터링 기법을 이용한 필댐의 안정성 평가)

  • Kim, Gi-Ho;Lim, Heui-Dae;Ahn, Hee-Yoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.53-64
    • /
    • 2013
  • Resistivity monitoring is based on the fact that a change in the porosity leads to the changes in water content and fine particles, which alter the electrical resistivity. At every embankment dam, internal erosion always occurs as time passes. The internal erosion generally develops into piping over a long time by backward erosion and concentrated leak, and finally leads to dam failure. Resistivity is known to be very sensitive to the changes in porosity in embankment dams. Thus resistivity monitoring is a reasonable method to find out the leakage zone. However, resistivity is strongly influenced by seasonal variation of temperature, TDS of reservoir water and water level. In this paper. we first installed electrodes permanently at the center of the crest. The electrical resistivity monitoring data was acquired every 6 hours from Apr. 3, 2011 to July. 31, 2012. To analyze the characteristics of monitoring data, each resistivity data was calculated from up to 2,950 data sets. The result indicated a seasonal resistivity variation due to related temperature. Finally, a quantitative method to estimate porosities of the embankment dam from the resistivity monitoring data was analyzed. The applicability and reliability were verified and the importance of electrical resistivity monitoring for obtaining reliable result was emphasized.

A Study on the Applicability of Levee Leakage Monitoring System Using Movable TDR Sensor (제방 누수 모니터링을 위한 이동식 TDR 센서의 적용성 평가)

  • Cho, Jinwoo;Choi, Bong-Hyuck;Cho, Won-Beom;Kim, Jin-Man
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2014
  • Several types of methods such as resistivity survey, ground penetration radar, etc are used for detection of levee leakage and according to the river design guidelines detection of levee leakage is performed by measuring the hydraulic conductivity of levee soil. But, the former can not verify the leakage point and degree of saturation, the latter is an after treatment method. Movable sensor, which is a high-tech TDR system developed since 2000, can obtain directly the dielectric constant profile covering the whole depth of levee. In this study, laboratory and field model experiments were carried out using movable TDR sensor in order to evaluate the applicability as detection system of levee leakage, As the result, movable TDR system has proven to be 3 times more sensitive to water contents than dry unit weight, and the results conclude that the dielectric constant, water contents and density of the ground proved to have a correlation among them, and the dielectric constant is expected to be a basic data on detection of levee leakage.

Electrical Resistivity Survey for Evaluation of Grouting Effect in Earth Dam (그라우팅에 의한 댐체의 보강효과 평가를 위한 전기비저항탐사)

  • Im, Eun-Sang;Oh, Seok-Hoon;Kim, Young-Kyung;Oh, Byung-Hyun
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.4
    • /
    • pp.455-462
    • /
    • 2006
  • In this paper, we used the electrical resistivity survey as a simple and reasonable technique to evaluate the effectiveness of grouting. And, a mechanism was also analyzed to understand how the electrical resistivity is affected by the loss of fine material in the core of a dam. From this mechanism, it was confirmed that electrical resistivity value of the damage section may be up or down depending on the survey conditions. This result seems to be contrary to the previous study that electrical resistivity of the damage zone become alway low. To clarify what was investigated, the electrical resistivity before and after grouting was compared and analyzed. As the result, it was concluded that grouting effectiveness was successfully assessed by electrical resistivity survey.

  • PDF