• Title/Summary/Keyword: 뇌혈관 중재술

Search Result 6, Processing Time 0.018 seconds

Bow Hunter's Syndrome Caused by Bilateral Dynamic Occlusion of the Subaxial Vertebral Arteries during Neck Extension (경추 신전 시 축하 척추동맥의 양측성 동적 폐쇄로 인해 발생한 보우 헌터 증후군)

  • Yi, Jemin;Han, Ho Sung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.85-89
    • /
    • 2020
  • Bow hunter's syndrome is a rare disease that shows the symptoms of vertebrobasilar insufficiency resulting from a dynamic obstruction or stenosis of the vertebral arteries during neck movement. This paper reports a case of a 59-year-old male who visited the emergency room with diplopia, tinnitus, and gait disturbance. Magnetic resonance imaging and angiography revealed a multiple cerebellar infarct, total obstruction of the right vertebral artery, and dynamic obstruction of the left vertebral artery during neck extension. As the infarction worsened, a thrombectomy was done. Posterior decompression and fusion at C5-6 were performed for the left vertebral artery. The left vertebral arterial patency was confirmed by intraoperative and postoperative angiography. No recurrence of the symptoms was observed for six months after surgery. Physicians need to pay attention to the diagnosis of vertebrobasilar insufficiency caused by an obstruction of the vertebral arteries during neck extension in cervical instability patients.

Usefulness of 3D Rotational Angiography for Cerebral Vascular Diameter Measurement (뇌혈관 직경측정을 위한 3차원 회전 혈관조영술의 유용성)

  • Seung-Gi, Kim;Sang-Hyun, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Long-term Clinical Outcomes after Primary Percutaneous Coronary Intervention in Patients with Acute Myocardial Infarction-on the basis of 65 Years (급성 심근경색증 환자에서 일차적 관상동맥 중재술 후 장기적 임상 경과-65세를 기준으로)

  • Lee, Han-Ol;Jang, Seong-Joo;Kim, In-Soo;Han, Jae-Bok;Park, Soo-Hwan;Kim, Jeong-Hun;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.251-261
    • /
    • 2014
  • Primary percutaneous coronary intervention (PCI) has been found to be superior, in terms of hospital mortality and long-term outcome, compared with thrombolytic therapy in patients with acute myocardial infarction (AMI). However, the clinical benefits of primary PCI have not been precisely evaluated in elderly patients.1,974 patients (Group I: n=1,018, $age{\geq}65years$, $73.8{\pm}5.99years$; Group II: n=956, age<65years, $52.8{\pm}7.96years$) who underwent primary PCI for AMI at Chonnam National University Hospital between 2006 and 2010 were analyzed according to their clinical, angiographic characteristics for hospital and one-year survival. Group I had a higher percentage of women, diabetes mellitus, hypertension, multi-vessel disease and lower prevalence of current smoking, hyperlipidemia, familial history than Group II. Culprit lesions were at the left anterior descending artery, left circumflex artery, right coronary artery and left main artery in 42.8% vs. 45.0%, 34.1% vs. 29.6%, 14.6% vs 14.6, 2.7% vs. 1.6%, respectively (p=0.007). Stent diameter was smaller in group I ($3.17{\pm}0.39$ vs. $3.29{\pm}0.42mm$, p=0.001). In-hospital mortality was higher in group I (8.4 vs. 1.9%, p<0.001). There were significant differences in the rates of major adverse cardiac events between the two groups during one-year clinical follow-up (20.1 vs.14.0%, p<0.001). On multiple logistic regression analysis, systolic blood pressure<100mmHg, serum $creatinine{\geq}1.3mg/dL$, Killip class> I, multivessel disease, left ventricular ejection fraction <40% and cerebro vascular disease were independent predictors of one-year motality in patients over 65 years after PCI.

Duplex Sonography in Subclavian Steal Syndrome Treated by Stent Insertion (이중초음파검사상 빗장밑혈류빼앗김증후군이 관찰된 환자에서의 스텐트 삽입 후 추적)

  • Han, Minho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.370-374
    • /
    • 2018
  • Subclavian steal syndrome is a type of obstructive artery disease caused by severe stenosis and occlusion of a left proximal subclavian artery or brachiocephalic trunk. The resulting vertebro-basilar insufficiency symptoms are due to retrograde blood flow from the contralateral vertebral and basilar arteries into the low-pressure ipsilateral upper extremity vessels. For that reason, patients usually experience dizziness or arm ischemic symptoms. Neurointervention is an effective treatment for ischemic stroke, including the subclavian artery stenosis. This paper reports a patient with subclavian steal syndrome who had a vertebral artery Doppler waveform change in duplex sonography and a 12 mmHg difference in interarm systolic blood pressure. A stenotic lesion of the subclavian artery was treated effectively by inserting a precise stent. The follow up examination showed that the vertebral artery Doppler waveform change disappeared and recovered and that the 12 mmHg difference in interarm systolic blood pressure decreased to 5 mmHg after treatment.

Evaluation of Patient Radiation Doses Using DAP Meter in Interventional Radiology Procedures (인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가)

  • Kang, Byung-Sam;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipments in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effectives of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were $237.7Gy{\cdot}cm^2$ in TACE, $17.3Gy{\cdot}cm^2$ in AVF, $114.1Gy{\cdot}cm^2$ in LE PTA & STENT, $188.5Gy{\cdot}cm^2$ in TFCA, $383.5Gy{\cdot}cm^2$ in Aneurysm Coil, $64.6Gy{\cdot}cm^2$ in PTBD, $64.6Gy{\cdot}cm^2$ in Biliary Stent, $22.4Gy{\cdot}cm^2$ in PCN, $4.3Gy{\cdot}cm^2$ in Hickman, $2.8Gy{\cdot}cm^2$ in Chemo-port, $4.4Gy{\cdot}cm^2$ in Perm-Cather, $17.1Gy{\cdot}cm^2$ in PCD, and $357.9Gy{\cdot}cm^2$ in Vis, EMB. Dose referenece level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipments and procedures in the interventional radiology procedures, further studies and monitorings are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.