• Title/Summary/Keyword: 높이 재현성

Search Result 116, Processing Time 0.026 seconds

Development of Radiological Examination Aids for Accurate Lower Extremity Length Measurement (정확한 하지 길이 측정을 위한 방사선 검사 보조기구 개발)

  • Hee-min Ahn;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.6
    • /
    • pp.673-680
    • /
    • 2024
  • The purpose of the study is to produce an auxiliary device that can measure accurate actual values during radiological examination where the length of the lower extremities is different, and to provide accurate quantitative values for establishing surgical plans. After manufacturing the device, a height and length reproducibility experiment was conducted, and a quantitative evaluation was performed using the measured values. A qualitative evaluation was conducted with 10 orthopedic residents to evaluate its usefulness. In the height reproducibility test, the existing method was statistically significant at p<0.05 in all items except the 1.0 cm experiment, and the manufactured assistive device was not statistically significant at p≧0.05. In the length reproducibility test, p<0.05 was found for both the existing and manufactured assistive device methods. In the qualitative evaluation, the reliability value was 0.690 and the average value ranged from 4.30 ± 0.94 to 4.90 ± 0.31. In conclusion, I think that if the surgical plan is made by expressing the difference in leg length as a quantitative value by using the manufactured auxiliary device, it can greatly contribute to the completeness of the surgery.

고감도 화학물질 검출을 위한 대면적 Ag 코팅 고분자 나노기둥 SERS 활성 기판 제작

  • Im, Ha-Na;Kim, An-Na;Lee, Ho-Nyeon;Kim, Hyeon-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.92.1-92.1
    • /
    • 2018
  • 표면증강 라만 산란(Surface Enhancement Raman Scattering, SERS) 기판의 경우, 규칙적인 배열을 갖는 나노구조 및 나노패턴 기판과 금속 나노구조의 고밀도 패킹이 고감도 화학물질 검출에 중요하다. 또한 폭넓은 응용 가능성에도 불구하고 기판 제작의 비용이 높고 재현성이 떨어져 상용화에 어려움을 겪고 있다. 본 연구에서는 다공성 알루미나(Anodic Aluminum Oxide, AAO)를 사용하여 Ag 나노입자가 코팅된 나노기둥 배열(Nanopillar array)을 갖는 고분자 필름의 SERS-active 기판을 제작하여 공정비용을 낮추고, 대면적화로 생산성을 높이고자 한다. 다단계 양극산화 공정과 복제 기술을 통해 다양한 지름과 높이를 갖는 맥주병 형상의 나노기둥 배열을 제조하였고, aspect ratio가 2.3인 나노기둥 배열에서 최대의 SERS 신호 강도와 높은 재현성을 확인하였다. SERS 신호의 세기는 Ag 나노입자가 코팅된 나노기둥 배열의 열처리 온도와 분석 물질의 농도에 따라 비례하며 이를 바탕으로 정량적인 고감도 진단, 바이오 화학 물질 센서에 매우 적합함을 알 수 있다.

  • PDF

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

LED Light Source and its Application to Display (LED 광원을 이용한 디스플레이 개발)

  • Kim, Dae-Sik
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.232-233
    • /
    • 2004
  • LED 광원의 특성인 높은 색재현성, 친환경성, 저소비전력 등을 디스플레이 광원으로 그 활용도가 높이 평가되고 있다. 최근 비약적인 광효율 증가를 보이고 있는 고출력 LED 광원을 대화면의 LCD TV 용 BLU 와 Projection TV의 조명계에 적용하기 위하여 기술개발에 필요한 주요 요소들을 살펴본다.

  • PDF

A study on Pedestrian Accident Reconstruction Models: Comparison and Improvement (보행자-차량 충돌사고 재현모형 비교분석 및 개선 연구)

  • Jo, Jeong-Il;O, Cheol;Kim, Nam-Il;Jang, Myeong-Sun
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.4
    • /
    • pp.69-77
    • /
    • 2007
  • This study presents comparison results for pedestrian accident reconstruction models representing the relationship between collision speed and horizontal distance that a body travels while falling and sliding. A set of 49 reliable pedestrian accident cases are applied to compare the existing reconstruction models. In addition, the authors investigate the effects of a set of parameters associated with the effects of the frontal shape of a vehicle on the horizontal distance a pedestrian travels while falling and sliding. It has been revealed that the length of the bumper is the most dominant factor to affect the horizontal distance of pedestrian travel after collision. Further analyses utilizing more accident data need to conducted to develop a more accurate and reliable reconstruction model.

A Study on Efficiency Verification and Application of Planter Box Based Rainfall-Runoff Property (강우-유출특성에 따른 식생여과장치의 효율성 검증 및 적용에 관한 연구)

  • Kim, Chang-Hee;Baek, Jong Suk;Joon, Jung Do;Seung, Joo Jae;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.463-463
    • /
    • 2016
  • 최근 도시물순환 복원 및 치 이수효과 증대를 위해 저영향개발기법(Low Impact Development) 연구가 활발하게 진행 중이다. 하지만 대부분이 수치모델을 활용한 설계프로그램 개발에 대한 연구에 집중되어 있는 실정이며, 이러한 프로그램을 활용한 설계 시 최적의 매개변수 결정에 한계가 있다. 이러한 이유로 본 연구에서는 건축형 LID 요소 중 하나인 식생여과장치(Planter Box)의 모형실험을 통해 프로그램 모의에 필요한 매개변수를 추정하고, 모의를 수행한 후 모형실험 결과와 프로그램 모의 결과를 비교하여 최종적으로 식생여과장치의 설계 매개변수를 산정하고자 한다. 식생여과장치의 모형실험을 위하여 가로 1.5m, 세로 1.5m, 높이 1.5m로 실험 장치를 제작하였으며, 강우-유출수 실험 전 시료의 침투율, 함수비 등을 체크한 후 지속시간 1시간의 재현빈도 5년, 10년, 20년, 50년에 해당하는 강우강도에 대해 실험을 수행하였다. 실험결과로 나타난 자료는 SWMM 모형과 비교분석해 모형에 적용된 매개변수의 적합성을 분석하였으며, 재현빈도 5년, 10년, 20년의 경우 $R^2$ 값이 0.88~0.97로 실험 값과 모의 값의 연관성이 높게 나타났으며, 재현 빈도 50년의 경우 0.7835로 비교적 연관성이 낮게 나타났다.

  • PDF

Precise Estimation of Vertical Position Displacement by Replacement of CORS Antennas (위성기준점 안테나교체에 따른 수직위치 변동량의 정밀산정)

  • Jung, Kwang-Ho;Lee, Young-Jin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.4
    • /
    • pp.343-352
    • /
    • 2012
  • In order to precisely determine the vertical displacements of CORS antenna phase centers caused by their replacement, intensive research has been carried out in this paper throughout processing GPS measurements made before and after the events. After applying the estimated displacement in the data processing, results show that coordinate repeatability of the vertical component is able to be 7.9mm on average. Comparing with results (e.g., 23.5mm) without applying the displacement, it was possible to conclude that these accuracies are significantly improved, which is equivalent to those before the event of the replacement.

The Attributes of high-functional Information - Based on the Safety Information of Airlines (고기능성 정보의 속성에 관한 연구 -Airline Safety information을 중심으로)

  • Han, Ji-Ae;You, Si-Cheon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2010.05a
    • /
    • pp.135-137
    • /
    • 2010
  • 본 연구는 여러 정보환경 또는 정보 디자인 유형 중에서 짧은 정보 노출 시간에 비해 정보 전달력이 강해야 하는 정보유형의 인지력을 높이는 방법을 모색하기 위해 진행되었다. 이와 같은 정보를 본 연구에서는 '고기능성 정보(High-Functional Information)'라고 정의하고, 연구를 위해 7개 항공기에서 사용되고 있는 Safety Information을 중심으로, 고기능성 정보의 주요 속성과 그에 따른 거시적 정보 표현 방법에 대해서 연구하였다. 본 연구는 상황, 순서, 흐름, 구조 표현으로서의 정보디자인인 Safety Information을 기능변수에 대한 활용이 중요한 '고기능성 정보'라고 정의하고, 이에 대한 주요 정보 속성을 Accessibility, Errorless, Understandable, Timeliness로 제시하였다. 고기능성 정보는 맥락에 따라, 시각적 재현 측면에서 Understandable, Accessibility 속성이 충족되어야 하며, 사용자 조작 측면에서는 Errorless, Timeliness 속성이 충족되어야 한다. 각 측면에서의 거시적 표현 방법으로써, 시각적 재현 측면에서 독특 속성을 기반으로 한 속성이론, 도상화를 통한 "현실감지" 최대화, 정보 주도성(Proactivity), 잉여정보와 노이즈 정보의 최소화를 제시하였으며, 사용자 조작측면에서 맥락효과, 일차적 독특성을 중심으로 한 기억부호화, 이중부호화 및 표현 방법 등을 제시하였다. 본 연구에서의 개괄적인 연구 내용을 토대로 앞으로 정보환경 또는 디자인 유형과 속성에 따른 정보 표현방법에 관한 연구가 추진될 예정이다.

  • PDF

주사형 정전용량 현미경(SCaM)의 개발

  • 김응규
    • 전기의세계
    • /
    • v.42 no.9
    • /
    • pp.6-11
    • /
    • 1993
  • 미소탐침을 STM과 같이 PZT등의 압전액튜에이터로 대상물을 2차원 또는 2.5차원 주사해서 그 정전량을 화상화하는 주사형 정전용량 현미경(SCaM)의 개발에 대해서 기술했다. 광학현미경과 레이저현미경은 빛을 이용하기 때문에 파장의 제약을 받아 그 분해능의 한계는 0.3[.nu.m]정도이다. 이것에 대해 SCaM은 광학방식가 같은 분해능의 원리적 한계가 없고, 또한 광학상과는 다른 유전율상의 특성화상이 얻어진다. 이와같은 특징에 의해, 최종적으로 0.01[.mu.m]레벨의 분해능을 얻을 수 있는 실용레벨의 현미경을 시험제작함을 목적으로 하고 있다. 본 연구에서는 탐침과 시료표면간의 거리를 진동에 의해 미소로 변화시켰을 때의 정전용량의 변화를 포착하는 미분용량법을 이용했으며, 탐침높이 및 주사시에 있어서의 검출기 출력의 재현성, 즉 신호 검출방식으로서의 S/N이 양호한 동기검파를 이용했을 대해서 실험적 검토를 하였다. 이와같은 검파방식에 의해 잡음, 히스테리시스 등의 영향에 대해 개선이 되고, 분해능도 향상되었다. 더욱이 2.5차원 탐침 주사방식 미분용량형 정전용량 현미경에 의해 칼날 부분 선단부의 확대화상이 명료하게 얻어졌다. 그러나 실용적으로는 아직 불충분하다.

  • PDF

Word Alignment Using Chinese-Korean Linguistic Contrastive Information (중-한 대조분석정보를 이용한 단어정렬)

  • Li, Jin-Ji;Kim, Dong-Il;Lee, Jong-Hyeok
    • Annual Conference on Human and Language Technology
    • /
    • 2002.10e
    • /
    • pp.40-46
    • /
    • 2002
  • 본 논문에서는 범용 병렬코퍼스에서도 적용할 수 있는 단어정렬의 방법을 제안한다. 단어 단위로 정렬된 병렬코퍼스는 자연언어처리의 다양한 분야에 도움을 준다. 예를 들면 변환기반의 기계번역에서 변환패턴의 구축, MWTU(Multi Word Translation Unit)의 자동추출, 사전 구축, 의미 중의성 해소 등 분야에 적용된다. 중한 병렬 코퍼스의 단어정렬은 서로 다른 어족간의 관계의 규명을 포함하고 있기 때문에 본 논문에서는 통계적인 모델보다 중한 대역어 사전, 단일어 시소러스, 품사정보 및 언어학적 대조분석 정보 등 기존에 있는 리소스를 이용하여 재현율과 정확률을 높이는 방법에 대해 제시한다. 성능 평가를 위해 중앙일보에서 임의로 추출한 500개 대응문장을 이용하여 실험한 결과 82.2%의 정확률과 64.8%의 재현율을 보였다.

  • PDF