• Title/Summary/Keyword: 노하우

Search Result 552, Processing Time 0.018 seconds

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

A Study on the Influence of the Selective Attributes of Home Meal Replacement on Perceived Utilitarian Value and Repurchase Intention: Focus on Consumers of Large Discount and Department Stores (HMR(Home Meal Replacement) 선택속성이 지각된 효용적 가치, 재구매 의도에 미치는 영향에 관한 연구: 대형 할인마트와 백화점 구매고객을 대상으로)

  • Seo, Kyung-Hwa;Choi, Won-Sik;Lee, Soo-Bum
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.6
    • /
    • pp.934-947
    • /
    • 2011
  • The purpose of this study is to analyze products for good taste and convenience, which become an engine to constantly create customers. In addition, this study is aimed at investigating the relationship between the selective attributes of Home Meal Replacement, the perceived utilitarian value, and the repurchase intention, and drawing new suggestions on the Home Meal Replacement market from a new marketing perspective. Based on a total of 215 samples, this study reviewed the reliability and fitness of the research model and verified a total of 5 hypothesized using the Amos program. The result of study modeling was GFI=0.905, AGFI=0.849, NFI=0.889, CFI=0.945, and RMR=0.0.092 at the level of $x^2$=230.22 (df=126, p<0.001). First, the food quality (${\beta}$=0.221), convenience (${\beta}$=0.334), packing (${\beta}$=0.278), and employee service (${\beta}$=0.204) of home meal replacement consideration attributes had a positive (+) influence on perceived utilitarian value. Second, perceived utilitarian value (${\beta}$=0.584) had a positive (+) influence on repurchase intention. The factors to differentiate one company from other competitors in terms of the utilitarian value are the quality of food, convenience, wrapping, and services by employees. This study has illustrated the need to focus on the development of a premium menu to compete with other companies and to continue to research and develop nutritious foods that are easy to cook. Moreover, the key factors to have a distinct and constant competitive edge over other companies are the alleviation of consumer anxiety over wrapping container materials, the development of more designs, and the accumulation of service know-how. Therefore, it is necessary for a company to strongly develop the key factors based on its resources as a core capability.