• 제목/요약/키워드: 노면온도

검색결과 39건 처리시간 0.019초

기계학습을 이용한 노면온도변화 패턴 분석 (Analysis of Road Surface Temperature Change Patterns using Machine Learning Algorithms)

  • 양충헌;김승범;윤천주;김진국;박재홍;윤덕근
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.35-44
    • /
    • 2017
  • PURPOSES: This study suggests a specific methodology for the prediction of road surface temperature using vehicular ambient temperature sensors. In addition, four kind of models is developed based on machine learning algorithms. METHODS : Thermal Mapping System is employed to collect road surface and vehicular ambient temperature data on the defined survey route in 2015 and 2016 year, respectively. For modelling, all types of collected temperature data should be classified into response and predictor before applying a machine learning tool such as MATLAB. In this study, collected road surface temperature are considered as response while vehicular ambient temperatures defied as predictor. Through data learning using machine learning tool, models were developed and finally compared predicted and actual temperature based on average absolute error. RESULTS : According to comparison results, model enables to estimate actual road surface temperature variation pattern along the roads very well. Model III is slightly better than the rest of models in terms of estimation performance. CONCLUSIONS : When correlation between response and predictor is high, when plenty of historical data exists, and when a lot of predictors are available, estimation performance of would be much better.

소입경 골재노출콘크리트포장의 최적 배합 및 노출기법에 관한 연구 (A Study on the Optimum Mix and Exposing Method of the Fine-Size Exposed Aggregate PCC Pavements)

  • 김영규;이승우;유태석;김형배
    • 한국도로학회논문집
    • /
    • 제11권2호
    • /
    • pp.1-15
    • /
    • 2009
  • 골재노출콘크리트포장은 콘크리트 타설 직후 포장표면에 응결지연제를 살포하여 표면으로부터 깊이 2$\sim$3mm 정도의 모르타르 경화를 늦추게 한 후 표면의 모르타르 제거를 통해 굵은골재를 포장표면에 노출시키는 공법이다. 골재노출콘크리트포장의 타이어-노면 소음이 일반 콘크리트포장보다 작으면서도 적정한 미끄럼저항을 장기간 유지한다는 장점을 가지고 있다. 특히 굵은골재가 소입경일수록 소음저감효과가 우수한 것으로 알려져 있다. 성공적인 소입경 골재노출콘크리트포장의 건설을 위해서는 굵은골재의 최대입경이 적정하여야 하며, 적정량의 굵은골재를 포장표면에 균일하게 노출하도록 해야 하며 이를 위한 적절한 배합과 노출기법의 도출이 요구된다. 일반적인 콘크리트포장의 배합기준은 강도설계로 이루어지지만 소입경 골재노출콘크리트포장의 경우 강도뿐만 아니라 소음저감효과, 미끄럼저항을 적절히 발현시킬 수 있는 배합설계를 실시하기 위해서는 강도실험 외에도 노면의 미끄럼저항, 소음을 고려할 필요가 있다. 본 연구에서는 소입경 골재노출콘크리트포장에 대하여 적정 강도를 유지하며 포장표면조직의 소음 저감효과 및 적정 미끄럼저항성을 동시에 만족시킬 수 있도록 표면조직을 형성할 수 있는 최적배합에 대해 제시하였다. 또한 콘크리트포장은 온도, 습도 및 대기환경에 의해 모르타르의 경화속도가 달라지므로 콘크리트의 물리적 성질을 정량적으로 고려한 최적 노출기법이 제시되었다.

  • PDF

탄성포장재의 기초물성에 관한 실험적 연구 (An Experimental Study on the Basic Properties of Elastic Paving Materials)

  • 고훈범;고만영
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.5021-5028
    • /
    • 2015
  • 탄성포장재에 대한 기존의 연구는 포장재의 투수성, 공법적용에 관한 접근이 많아 탄성포장재의 기초적인 성능연구보다 실용화에 초점을 맞춘 연구가 많았다. 본 연구에서는 경제적인 차원에서 필요한 탄성조건과 투수성 등을 만족하면서 콘크리트나 아스팔트로 포장된 장소에서 기존 하층 노면에 대한 재시공 없이 자원낭비나 환경오염이 발생하지 않도록 두께가 얇은 탄성포장재의 시공 가능성에 대하여 두께가 다른 5종류(10, 13, 15, 20, 25mm)의 시험편과 고무 칩과 바인더의 혼합비가 다른 3개(20, 22.5, 25%)의 시험편을 가지고 다양한 시험을 실시하고 기본적인 물성을 파악하였다. 결과적으로 정성적인 관점에서 탄성바닥재의 두께를 품질조건에 따라 최소한(10~25mm)으로 할 수 있는 여지가 있으며, 바닥재가 온도에 민감하여 내구성증진에 대한 대안도 필요하다고 판단된다.

도로기상차량으로 관측한 노면온도자료를 이용한 도로살얼음 취약 구간 산정 (Estimation of Road Sections Vulnerable to Black Ice Using Road Surface Temperatures Obtained by a Mobile Road Weather Observation Vehicle)

  • 박문수;강민수;김상헌;정현채;장성빈;유동길;류성현
    • 대기
    • /
    • 제31권5호
    • /
    • pp.525-537
    • /
    • 2021
  • Black ices on road surfaces in winter tend to cause severe and terrible accidents. It is very difficult to detect black ice events in advance due to their localities as well as sensitivities to surface and upper meteorological variables. This study develops a methodology to detect the road sections vulnerable to black ice with the use of road surface temperature data obtained from a mobile road weather observation vehicle. The 7 experiments were conducted on the route from Nam-Wonju IC to Nam-Andong IC (132.5 km) on the Jungang Expressway during the period from December 2020 to February 2021. Firstly, temporal road surface temperature data were converted to the spatial data with a 50 m resolution. Then, the spatial road surface temperature was normalized with zero mean and one standard deviation using a simple normalization, a linear de-trend and normalization, and a low-pass filter and normalization. The resulting road thermal map was calculated in terms of road surface temperature differences. A road ice index was suggested using the normalized road temperatures and their horizontal differences. Road sections vulnerable to black ice were derived from road ice indices and verified with respect to road geometry and sky view, etc. It was found that black ice could occur not only over bridges, but also roads with a low sky view factor. These results are expected to be applicable to the alarm service for black ice to drivers.

2023년 여름철 폭염 집중관측을 통한 서울 도심환경 조건에 따른 기온 및 노면 온도의 변화 특성 (Characteristics of Changes in Air and Road Temperatures Induced by Environmental Conditions in the Urban Region of Seoul Through an Intensive Observing Period (IOP) of Heatwaves in the Summer of 2023)

  • 나성준;한상대;김제원;박문수;김백조
    • 한국환경과학회지
    • /
    • 제33권1호
    • /
    • pp.75-85
    • /
    • 2024
  • An intensive observing period (IOP) of heatwaves in the urban region of Seoul in the summer of 2023 was carried out to understand the changes in air temperature and road temperature induced by environmental conditions. The temperature observed at eight points with different urban environmental conditions was compared with the temperature by the KMA/AWS to analyze the characteristics of change in air temperature by height and the change in road temperature according to environmental conditions and road sprinkler. The comparison of the average temperature observed in different urban environmental conditions with the temperature observed at KMA/AWS showed that the air temperature in asphalt and open space sites was 0.7 to 2.3℃ higher and that the one in bus stops was 0.9 to 2.3℃ higher. In terms of temperature deviations depending on residential type, the temperature in highly populated areas was about 0.1 to 0.8℃ higher than that of apartment complexes. In addition, regardless of the size of a park, the temperature in the park was lower than the temperature in dense housing areas and apartment complexes. In asphalt and residential areas, the road temperature was higher than the temperature at a height of 150 cm, Conversely, road temperature was lower than air temperature in a shaded shelter and large park. In addition, after spraying a surface road, the road temperature immediately dropped by about 3 to 4℃; however, after about 20 minutes, it rose again to the previous road temperature. This change in road temperature appeared only for the temperature of 30 cm height.

소입경 골재노출콘크리트포장의 환경하중 저항성에 대한 연구 (A Study on the Resistance Against Environmental Loading of the Fine-Size Exposed Aggregate Portland Cement Concrete Pavements)

  • 전범준;이승우;채성욱;배재민
    • 한국도로학회논문집
    • /
    • 제11권2호
    • /
    • pp.99-109
    • /
    • 2009
  • 소입경 골재노출콘크리트포장은 콘크리트 타설 직후 포장표면에 응결지연제를 살포하여 표면으로부터 깊이 2$\sim$3mm 정도의 모르타르 경화를 늦추게 한 후 표면의 모르타르 제거를 통해 굵은골재를 포장표면에 노출시키는 공법이다. 소입경 골재노출콘크리트포장은 타이어-노면 소음이 일반 콘크리트포장보다 4$\sim$5dB(A)정도 작으면서도 적정한 미끄럼저항을 장기간 유지한다는 장점을 가지고 있다. 소입경 골재노출콘크리트포장이 적정 평균조직깊이, 노출도 및 미끄럼저항을 확보하여 강도, 소음저감효과 및 장기간 적정 미끄럼저항성을 유지 하는 것도 중요하지만 성공적인 소입경 골재노출콘크리트포장의 건설을 위해서는 온도, 습도 등의 요인으로 발생하는 환경하중에 대한 내구성이 요구된다. 콘크리트포장은 타설 후 경화과정에서 수분손실 및 초기건조로 인하여 필연적으로 체적변화가수반되며 과도한 체적변화는 콘크리트 균열발생에 주요한 원인이 될 수 있다. 동결융해를 받고 있는 지역에서 제설제를 사용할 경우 표면박리현상이 발생한다. 이러한 균열 및 스케일링은 포장체의 내구성을 저하시키고 미끄럼저항을 감소시켜 장기공용성을 단축시키는 직접적인 요인으로 작용하게 된다. 따라서 본 연구에서는 소입경 골재노출콘크리트포장에 대하여 수분증발로 인한 수축균열 제어 성능 및 제설제를 사용하였을 경우에 반복되는 동결융해작용으로 인한 스켈링에 대해 내구성을 평가하여 환경하중 저항성에 대해 고찰하였다.

  • PDF

이미지프로세싱을 이용한 도로포장의 균열폭 측정에 관한 연구 (Measurement of Crack Width of Pavements Using Image Processing)

  • 고지훈;서영찬
    • 한국도로학회논문집
    • /
    • 제4권2호
    • /
    • pp.33-42
    • /
    • 2002
  • 포장은 건조수축이나 온도변화 또는 차량의 반복하중 등으로 인하여 균열이 발생하게 된다. 발생된 균열 부위로 우수의 침입 및 비압축성 물질이 침투하여 하부층의 지지력 저하, 과다한 스폴링, 2차 균열 등의 파손이 발생하게 된다. 이런 문제점을 해소하기 위해서는 균열폭을 제한하여 관리해야하며 이것은 정확한 균열폭 감지를 필요로 한다. 현재의 측정방법은 공간적 시간적으로 많은 제약을 받는 현미경을 이용한 육안조사가 전부인 실정이다. 본 연구의 목적은 망원렌즈를 장착한 자동포장상태 조사장비를 사용하여 도로에서 주위차량과 비슷한 속도로 주행하면서 가장 정확한 균열폭을 감지할수 있는 조건을 찾는 것이다. 본 연구는 모의조사를 통하여 균열폭 크기에 따른 카메라 초점거리를 결정하고 망원렌즈를 부착한 카메라로 노면을 확대 촬영한 자료를 이미지프로세싱 프로그램인 STADI-2에서 여러 가지 factor를 사용하여 산출된 균열폭과 현장조사를 통하여 현미경으로 실측한 균열폭을 비교 분석한 결과, 이미지프로세싱을 이용한 최적균열폭 감지조건을 제시하였다. 연구결과 CRCP(연속철근콘크리트포장)에서는 카메라 초점거리 75mm를 사용하여 균열폭 0.5mm$\sim$1.2mm일때 정확도 80%이상으로 측정 가능했으며 아스팔트포장에서는 카메라 초점거리 12.5mm를 사용하여 균열폭 1.8mm$\sim$3.3mm에서 90%의 정확도로 균열폭을 감지할 수 있었다.

  • PDF

3축 가속도센서를 이용한 자전거의 주행 상황 인식 기술 개발 (Bicycle Riding-State Recognition Using 3-Axis Accelerometer)

  • 최정환;양윤석;유문호
    • 전자공학회논문지SC
    • /
    • 제48권6호
    • /
    • pp.63-70
    • /
    • 2011
  • 자전거는 자동차와 달리 사용자인 탑승자가 외부 환경에 그대로 노출되므로, 주변 날씨, 대기, 주행 경로 등에 관한 정보를 자동차 보다 오히려 폭넓게 활용할 필요가 있다. 더욱이 자전거는 인간의 힘을 동력으로 사용하므로 도로의 경사, 굴곡, 노면 상태와 같은 주행 경로의 특성을 미리 파악할 수 있다면 최적 경로 추정 등을 통해 이동 효율을 획기적으로 높이는 데에 도움이 될 것이다. 최근의 모바일 정보 서비스와 함께 개발되는 각종 자전거용 애플리케이션들은 이러한 지능형 자전거를 위한 체계적인 연구 개발의 필요성을 일깨우고 있다. 본 연구에서는 무선 통신이 가능한 저전력 손목 시계형 임베디드 장치를 자전거에 간단히 장착하고, 여기에 내장된 가속도 센서를 이용하여 자전거의 주행 상황 (오르막, 내리막, 정지, 가 감속) 을 자동으로 인식할 수 있는 알고리듬을 개발하는 것을 목표로 하였다. 개발된 알고리듬의 신뢰성을 검사하기 위해 총 19 개의 실험 주행 데이터에 적용한 결과, 전체 실험 데이터의 83.3% 에서 95% 이상의 구간 인식 정확도를 얻을 수 있었다. 향후 임베디드 장치에 내장된 고도 센서, 온도 센서를 추가로 활용하여 탑승자의 신체 상태 및 운동 추정이 가능한 지능형 자전거를 개발할 계획이다. 개발된 주행 상황 인식 기술은 주행 중의 안전을 고려한 지능형 인터페이스 기술의 기반이 될 수 있을 것으로 기대한다.

LID 시설 내 IoT 기술을 활용한 오염물질 상관성 분석 (Correlation analysis of pollutants using IoT technology in LID facilities)

  • 전민수;최혜선;;;김이형
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.453-453
    • /
    • 2021
  • 도시지역 비점오염원관리, 물순환 회복, 침투 및 증발산량 증가, 열섬현상 저감을 위한 주요한 방안으로 저영향개발(low impact development, LID)과 그린인프라 기법의 적용되고 있다. LID 시설은 소규모 분산형 시설로써 넓은 지역에 많고 다양한 시설들이 적용되어 시설의 개수가 많으며, 수질 및 토양 내 기성제품에 대한 센서들의 가격은 고가로 형성되어 있어 기기의 경제성 및 유지관리 등 적용하는데 제한적이다. 따라서 과거 모니터링 자료를 기반으로 오염물질들과의 상관성 분석을 통하여 계측이 어려운 항목들을 계측가능한 항목들로부터 예측 가능하며, 선정된 항목들에 대한 비용효율적인 센서를 개발하여 실시간 LID 모니터링이 가능한 비용효율적 모니터링을 개발하였다. 공주대학교 천안캠퍼스의 LID 시설들은 2013년에 조성되어 현재까지 시설이 운영되고 있으며, 5년이상의 과거 강우시 모니터링 자료들을 이용하여 오염물질 상관성 분석을 수행가능 하기에 대상지로 선정하였다. 오염물질 상관성 분석은 2013년부터 2017년도에 침투도랑에서 수행된 강우시 모니터링 자료를 활용하여 각 오염물질들의 상관성을 분석을 수행하였다. 침투도랑 내 유입되는 평균 유입수는 TSS 286.1±318.3 mg/L, BOD 22.6±39.5 mg/L, TN 8.96±5.85 mg/L, TP 1.01±1.11 mg/L로 나타났다. 겨울철에 비해 여름철에서의 오염물질의 유입농도가 높은 것으로 분석되었다. 이는 여름철 고온건조로 인한 노면 내 차량의 주행으로 인한 중금속, 폐타이어 등과 장마철 강우 시 유출된 토사로 인하여 유입수의 농도가 높은 것으로 분석되었다. 오염물질 부하량은 TSS와 COD 0.66으로 유의성이 높은 것으로 나왔으며, COD와 TSS, TP, TN 등 유의성이 높은 것으로 분석되었다. Arduino와 Raspberry PI를 활용하여 저비용 센서와 LTE 모뎀통신과 데이터 베이스 연결하여 개발된 프로그램을 통해서 무선으로 LID 시설에 대한 모니터링을 침투화분2와 식생체류지에 조성하였다. 전력공급이 어려운 식생체류지의 경우 태양열(Solar system) 시스템과 보조 전력 배터리를 조성하여 장마철이나 장기적인 악천후로 인한 전력을 생산하지 못할 경우 보조전력배터리에서 전력을 제공하여 지속적인 모니터링이 이루어지도록 설계하였다. 토양함수량, 토양온도와 Conductivity 등 3종류의 센서를 적용하였으며, 프로그램은 현재 2단계를 통한 2차수정을 통하여 프로그램을 구축하였다. 오차, 오작동, 계측값에 대한 검·보정 작업이 필요하다. 또한 대기자료의 구축을 통해 보다 토양과 LID 시설에 대한 영향분석이 필요한 것으로 사료된다.

  • PDF